Ex-Data; Specifications; Cleaning, Maintenance And Storage - Ecom Instruments Ex-CDMA 02 Safety Instructions

Non-incendive cell phone
Table of Contents

Advertisement

- The battery may only be changed or charged outside the hazardous area.
- It is not allowed to carry additional battery packs in the hazardous area.
- Only AM CDMA 00036 batteries specified by the manufacturer may be
used.
- The use of other batteries is strictly prohibited and will result in the nullifica-
tion of explosion protection.
- The battery may only be charged outside the hazardous area using the ap-
propriate travel charger Kyocera Travel Charger Model: TXTVL0072. Other
chargers that are suitable for the unit may also be used.
At the moment are no suitable accessories for the hazardous area available
It must be ensured that the unit is only taken into areas according Class
Div2.

5. Ex-Data

FM-Indicator: NI/I/2/ABCD T6
Ta = -22° to +40°F ( -30° to +60°C )
Intrinsically Safe for use in a Class I, Division 2, Groups A, B, C & D with a
Temperature class of T6

6. Specifications

Operating voltage:
Dimensions (LxWxD):
Weight:
Battery / power supply: AM CDMA 00036
Operating time:
Ambient temperature Ta: -22° to +40°F ( -30° to +60°C )
Storage temperature:

7. Cleaning, maintenance and storage

- Only use a damp and suitable cloth or sponge to clean the unit. Do not use
any solvents or abrasive cleaning agents when cleaning.
- It is recommended that you have the functionality and accuracy of the unit
inspected by the manufacturer every two years.
- The battery should be removed from the unit during prolonged periods of
storage.
- Do not allow storage temperatures to exceed or fall below the permitted
range of -22° to +40°F ( -30° to +60°C ).
4
3.7 V
50 x 50 x 35 mm
approx. 200g
(standby/RX/TX) 5 hours (90/5/5)
-22° to +40°F ( -30° to +60°C )

Advertisement

Table of Contents
loading

Table of Contents