- It must be ensured that the unit is not taken into zones 0, 1, 20,
21 or 22 .
- Observe the corresponding laws that are in force in the respe
tive country regarding the use of mobile phones while operating
a vehicle.
- Use of the mobile phone in an aeroplane is not permitted.
- Switch off the mobile phone when in close proximity to medical
instruments and if you are requested to do so by corresponding
regulations.
- Manufacturers of cardiac pacemakers recommend a minimum
distance of 15.3 cm (6") is maintained between a mobile phone
and a pacemaker.
- Do not switch on the mobile phone when the use of such devices
is prohibited, as it may cause interference or result in danger.

5. Ex-Data

Certificate of conformity:
Ex-Designation:
Ambient temperature range:
Approved for zone 2, device group II, explosion group IIC (explosi-
ve gases, vapours or mist), temperature class T4.

6. Technical specifications

Networks:
Bluetooth:
Display:
Power supply:
Dimensions:
Weight:
CE-designation:
Protection class:
SAR:
ecom-10-501 X
-20 °C ... +55 °C
EDGE Tri-Band 900, 1800 and 1900 MHz
2.0 (DUN, OPP, SPP, HSP, HFP)
176 x 220 pixels, 65536 colours
ecom BPX 21x, Li-Ion 3,7 V, 1750 mAh
119 x 56 x 26 mm
approx. 170 g incl. battery
0
IP 67
The highest SAR value for the X.com 21x -Ex
which has been tested for use without a
headset is 0.582 W/kg (10 g).
II 3G Ex nA nL IIC T4 Gc
15

Advertisement

Table of Contents
loading

Table of Contents