Caveats
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Workaround: This issue is resolved.
CSCsq69543
Symptom: Fabric Manager does not update Port Channel changes.
Workaround: This issue is resolved.
CSCso72230
Symptom: In rare instances, the following Generation 2 modules might reload:
The output of the show logging log command will have events like those shown below. In the
following output, module 7 is the supervisor and module 12 is the module that reloaded.
2008 Jul 15 19:39:30 fcd95c41 %MODULE-4-MOD_WARNING: Module 7 (serial: JAE1134UR88)
reported warnings on ports 7/1-7/3 (Unknown) due to BE2 Arbiter experienced an error
in device 65 (device error 0xc410d613)
2008 Jul 15 19:39:30 fcd95c41 %MODULE-4-MOD_WARNING: Module 8 (serial: JAE1134UOTD)
reported warnings on ports 8/1-8/3 (Unknown) due to BE2 Arbiter experienced an error
in device 65 (device error 0xc410d613)
2008 Jul 15 19:39:35 fcd95c41 %XBAR-5-XBAR_STATUS_REPORT: Module 12 reported status
for component 88 code 0x40240015.
2008 Jul 15 19:39:35 fcd95c41 %MODULE-2-MOD_DIAG_FAIL: Module 12 (serial: JAE1136VU6L)
reported failure on ports 12/1-12/24 (Fibre Channel) due to Fatal runtime Arb error.
(DevErr is bitmap of failed modules) in device 88 (device error 0x800)
"show logging onboard" will show log similar to the one below for the reloaded module:
Logging time: Tue Jul 15 19:39:28 2008
machine check: process swapper (0), jiffies 0x744af3a4
Free pages in zone[0]:0x4a70,zone[1]:0x0,zone[2]:0x0
Stack: c000dd58 c001eefc c000b2c4 c000ae98 d2060e10 c003d7a4 c00f869c c0045cdc
d196c584 d196d100 c000c31c c000c3e4 c000ae90 c000c910 c000c924 c0008948 c01ca610
c0000394
...................
..................
Workaround: This issue is resolved.
The software workaround for this issue helps reduce instances of module reloads, but does not
completely eliminate the problem. Consequently, module reloads might still occur.
CSCsq80132
Symptom: Selecting disks as a part of the tape device configuration causes a CPP SME process
failure.
Workaround: This issue is resolved.
CSCsr11269
Symptom: When fctimer CFS distribution is enabled, no commit can be successful, and no change
can be made. The error message is as following:
dctl-m9509-190-NAC-B1(config)# fctimer E_D_TOV 1050 vsan 1
Warning:The vsan will be temporarily suspended when updating the timer value
This configuration would impact whole fabric.
Do you want to continue? (y/n) y
2008 Jul 1 11:34:39 dctl-m9509-190-NAC-B1 %CFS-2-MTS_REJECT: Verification failed
reject MTS message SAP 15:RR-token 0x64f82
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2)