S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
CSCsr49954
Symptom: The Recoverpoint Appliance with a QLogic HBA sends an 8 byte RFT_ID instead of the
standard 32bytes, which causes FC4 features to be incorrectly registered with all features.
Workaround: This issue is resolved.
CSCsr53531
Symptom: In IVR NAT environment, after active mode PortChannel flaps, some member of the
PortChannel may not get programmed in the IVR table, so that related IVR traffic will get lost.
Workaround: This issue is resolved.
CSCsr94621
Symptom: A Fiber Channel over IP (FCIP) trunk can go down if the maximum transmission unit
(MTU in the path is less than the MTU of the MDS Gigabit Ethernet interface.
Workaround: This issue is resolved.
CSCsr98144
Symptom: If a sync-loss is received for a nonexisting fabric, the xbar-manager transitions to a state
from which it does not exit.
Workaround: This issue is resolved.
CSCsu06940
Symptom: An Octeon core occurred.
Workaround: This problem is resolved.
CSCsu31223
Symptom: A slow memory leak has been found as a part of the view of the interface table MIB with
the SME interfaces. This eventually results in the SNMPD process resetting due to lack of memory.
Workaround: This issue is resolved.
CSCsr02430
Symptom: After issuing the show boot command, there are duplicate image names listed in the switch
output as shown below:
switch# show boot
sup-1
kickstart variable not set
system variable = bootflash:/m9500-sf1ek9-mzg.3.4.1.bin;bootflash:/m9500-sf1ek9-
mzg.3.4.1.bin
sup-2
kickstart variable not set
system variable = bootflash:/m9500-sf1ek9-mzg.3.4.1.bin;bootflash:/m9500-sf1ek9-
mzg.3.4.1.bin
No module boot variable set
switch#
This occurs if you issue the boot system command twice with the same image name as shown below:
switch(config)# boot system bootflash:m9500-sf1ek9-mzg.3.4.1.bin
switch(config)# boot system bootflash:m9500-sf1ek9-mzg.3.4.1.bin
Workaround: This issue is resolved.
CSCsq64637
Symptom: All device aliases in Fabric Manager disappear when adding new device aliases.