Download Print this page

HP AA979A - StorageWorks SAN Switch 2/8V Release Note page 33

Hp storageworks fabric os 4.4.0f release notes (aa-rw89a-te, october 2005)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:

Advertisement

For details on the switchShutdown command, refer to the
command reference guide
Power off the chassis by flipping both AC power switches to "0" (LEDs inside AC power switches
should turn off). To maintain the ground connection, leave both power cords connected to the
chassis and to an electrical outlet.
On Page 110, add the following paragraph before the Note:
A SAN Director 2/128 that is fully populated with FC2-16 blades can function on one power
supply. Redundancy of the power supply is achieved using power supply FRUs in slots 1 and 2. You
can populate all 4 power supply slots in the SAN Director 2/128 for maximum redundancy. Power
supply FRUs are interchangeable between the Core Switch 2/64 and SAN Director 2/128.
On page 110, replace the following statement in the section "Replacing a power supply and filler
panel":
The left power connector provides power to the power supplies in slots #1 and #3 and the
right power connector provides power to the power supplies in slots #2 and #4. The power
connectors and the power supply slots are color coded to identify which power connectors
provide power to which power supply slots. See Figure 1 on page 16 for power supply
location.
With this statement:
The left power connector provides power to the power supplies in slots #1 and #3
(color-coded blue). The right power connector provides power to the power supplies in
power supply slots #2 and #4 (color-coded yellow). The power connectors and the power
supply slots are color coded to identify which power connectors provide power to each of
the power supply slots. See Figure 1 on page 16 for power supply locations.
.
HP StorageWorks Fabric OS 4.x
Fabric OS 4.4.0f release notes
33

Advertisement

loading