Download Print this page

HP AA979A - StorageWorks SAN Switch 2/8V Release Note page 28

Hp storageworks fabric os 4.4.0f release notes (aa-rw89a-te, october 2005)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:

Advertisement

On page 132, the following text should be added to the "Creating and Modifying Zoning
Configurations" section:
When enabling a new zone configuration, you must ensure that the size of the configuration does
not exceed the minimum size supported by all switches in the fabric. This is particularly important if
and when you downgrade to a Fabric OS version that supports a smaller zone database than the
current Fabric OS version. In this scenario, the zone database in the current Fabric OS version
would have to be changed to the smaller zone database before the downgrade.
You can use the cfgSize command to check both the maximum available size and the currently
saved size on all switches. Refer to the
details on the cfgSize command. If you believe you are approaching the maximum, you can
save a partially completed zoning configuration and use the cfgSize command to determine the
remaining space."
HP StorageWorks Fabric OS 4.x features overview, part number:
AA-RVHTA-TE
On page 26 in the first paragraph, replace the following text:
Cable lengths for participating links should differ no more than 30 meters.
With this text:
Cable lengths for participating links should differ no more than 550 meters. For optimal
performance, HP recommends a difference no greater than 30 meters.
HP StorageWorks Fabric OS 4.x Fabric Watch user guide,
part number: AA-RVJ0A-TE
The following rows replace the existing rows "Invalid CRC Count," "Link Failure Count," and "State
Changes" in Table 25, "Port Class Threshold Defaults," on page 93.
Area
Link Failure Count
Invalid CRC Count
Invalid CRC Count
28
HP StorageWorks Fabric OS 4.x features overview, part number: AA-RVHTA-TE
HP StorageWorks Fabric OS 4.x command reference guide
Description
Default Threshold
Settings
Monitors the
Unit: Errors
number of link
Time Base: minute
failures
Low: 0
High: 5
Buffer: 0
Monitors the
Unit: Errors
number of CRC
Time Base: minute
errors
Low: 0
High: 5
Buffer: 0
Monitors state
Unit: Changes
changes
Time Base: minute
Low: 0
High: 5
Buffer: 0
Default Alarm
Threshold State
Settings
Changed: 0
Informative
Below: 0
Informative
Above: 0
Out of range
In-between: 0
In range
Changed: 0
Informative
Below: 0
Informative
Above: 0
Out of range
In-between: 0
In range
Changed: 0
Informative
Below: 0
Informative
Above: 0
Out of range
In-between: 0
In range
for

Advertisement

loading