HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 24

Hp storageworks fabric os 6.1.1b release notes (5697-7838, march 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Fabric OS 6.1.1 fixes
Table 10
lists defects closed in the Fabric OS 6.1.1 firmware release.
Table 10 Fabric OS 6.1.1 closed defects
Closed defect summary
During storage failover/failback test, traffic stops and fails to recover
in single and dual backbone configurations.
A failure was detected in the MP Router blade (FR4–18i) due to a dead
heartbeat.
Link drops when FLOGI is received before the port comes online on
an FL_Port.
Internal server ports on an embedded platform; traffic may stop due
to loss of buffer credit.
Mixed fabric of McDATA and Brocade switches cannot be managed
if only IPv6 addressing is supported.
HBA is not following Fibre Channel protocol standards, which could
cause a switch reboot.
Problems in an IP network could cause a switch running Fabric OS
5.3.x to panic.
Device with slow initialization sequence may cause the switch to mis-
takenly establish virtual channels on an F_Port.
Web tools zoning breaks when third party storage virtualization appli-
ance is changed to standby mode leading to Web Tools hangs.
FICON tape write pipelining selectively resets after CmdRetry to
NoOp sequence to LBY, causing tape job failures.
F_Port link initialization failure exposed by new third-party device be-
havior, where switch continues to send idles after NOS from HBA.
SupportSave command using DCFM does not contain information
from the standby CP.
HP 400 Multi-Protocol Router sends the wrong sense code during tape
backup with pipelining enabled.
Web Tools: DCX blade attention LEDs on the switch view GUI window
do not turn amber when the blade needs attention.
FICON PTP VTS selective resets and aborted sequences are caused
by incorrect entry into FICON tape read pipelining.
After renaming a port group name to blank from Web Tools, the port
group is deleted.
If EE monitors are restored from flash on a switch that has TopTalker
monitors, there is no warning or error when the TopTalker monitor in-
stallation recovery fails.
24
Solution
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.
Fixed in Fabric OS 6.1.1.

Advertisement

Table of Contents
loading

Table of Contents