HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 21

Hp storageworks fabric os 6.1.1b release notes (5697-7838, march 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Integrated routing
FCS automatic distribution
10-Gb interoperability
Port Fencing
Extended fabrics and
R_RDY flow control
Additional Fabric OS 6.1.x enhancements
This section describes additional Fabric OS 6.1.x enhancements:
Provides new Fabric OS commands to rename an alias, zone, and zone configuration:
• zone –copy—Copies the zone object to a new zone object
• zoneobjectrename—Renames the zone object
Detects and handles a corrupted zone configuration (under /etc/fabos/zone*) without re-
booting. The switch also logs the error in RASLog.
Adds a command that provides both the WWN and serial number of the switch. The –sn option
displays the serial number. For example, wwn –sn returns both the WWN and the serial number
Provides additional information on a faulty port in Fabric Watch to aid in troubleshooting.
Enables use of passive FTP to download firmware.
Enables the user to specify a quality password policy that prevents the selection of passwords with
consecutive, identical characters.
Uses multiple NTP servers with the tsclockserver command for redundancy. For example, if
one NTP server fails (DR scenario), there is a backup that switches can access.
Logs a RASLog message when a 2.x switch joins the fabric.
The HP 8/40 SAN Switch does not support Hot Code Load from Fabric OS 6.1.0
to 6.1.1b in a dual backbone configuration with a routed connection to an M-EOS
product.
When using the FCS automatic distribution feature in Fabric OS 6.0 or later, all
switches in the fabric must be running Fabric OS 6.0 or later. If any switches are
running Fabric OS 5.x or ealier, only manual distribution can be used.
Fabric OS 6.0 or later allows only FCS automatic distribution when in strict mode,
requiring only switches with Fabric OS 6.0 or later.
10-Gb interoperability between FC10–6 and McDATA blades is not supported
due to a HW limitation, however, the FC10–6 is supported in chassis running in
Interopmode 2 or 3 (FC10–6 to FC10–6 connections only). An FC10–6 blade
will not synchronize with a McDATA 10-Gb blade, but will not negatively affect
the system.
Port Fencing is supported only on E_Port and F_Port classes. Port fencing is
available with the optional Fabric Watch license.
Starting with Fabric OS 5.1, the Extended Fabrics feature is supported in
conjunction with R_RDY flow control. R_RDY flow control mode can be enabled
using the portCfgISLMode command. R_RDY flow control mode that uses IDLE
primitives does not support HP frame-based trunking for devices such as Time
Division Multiplexor (TDM). To support frame-based trunking with extended fabrics,
Fabric OS 6.1.1b has been enhanced to support interoperability with these
distance-extension devices.
Fabric OS 6.1.1b allows extended fabric E_Ports to operate in VC_RDY mode
using ARB or IDLE primitives as fill words. This allows frame-based trunking on
extended fabric E_Ports even with IDLE primitives are configured for these ports
when operating in native VC_RDY mode. Before this change, frame-based trunking
was supported only when ARB primitives were used in VC_RDY mode. With Fabric
OS 6.1.1b, frame-based trunking is supported on extended fabric E_Ports,
regardless of whether IDLE or ARB primitives are used when operating in native
VC_RDY mode.
HP StorageWorks Fabric OS 6.1.1b release notes
21

Advertisement

Table of Contents
loading

Table of Contents