26
HP Surestore VA 7400
The FC 16B also can support a 2Gb connection to an HP Surestore Virtual
Array 7400. Set the port speed to 2Gb using the telnet command
.
portCfgSpeed
Use the Virtual Front Panel (VFP) on the VA 7400 and configure the device
as follows:
1. Change the controller port data rate to 2 Gbits/s
a. To change the port data rate to 2 gigabits/second for controller 1, enter:
vfpmgr -S 2 -c 1
When prompted to reset, enter
b. To change the port data rate for controller 2, enter:
vfpmgr -S 2 -c 2
When prompted to reset, enter
changed. If all changes have been made, enter
2. Change the controller port topology.
a. To change the port topology for controller 1 enter the following
command, selecting
vfpmgr -t 4 -c 1
When prompted to reset, enter
b. To change the port topology for controller 2 enter the following
command, using the same topology value used for controller 1:
vfpmgr -t 4 -c 2
When prompted to reset, enter
changed. If all changes have been made, enter
Private Loop Devices
To work with private loop devices such as the FC 60, the FC 10, or the
SCSI bridge FC 4/2, set the FC 16B switch port as an L_PORT. See the
telnet command
portCfgLport
.
no
if additional settings must be
no
for Direct Fabric Attach:
4
.
no
if additional settings must be
no
.
to reset the array.
yes
to reset the array.
yes
Quick Start Guide