Entrapment Protection Devices - Chamberlain Elite RSL12V Installation Manual

Elite series vehicular slide gate operator
Hide thumbs Also See for Elite RSL12V:
Table of Contents

Advertisement

ADDITIONAL FEATURES
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect anyone who may
come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the open and close
gate cycles.
CONTACT SENSORS (EDGE SENSOR)
Edge sensor models G65MG0204, G65MG0205, G65MGR205 or G65MGS205
(2-wire, non-monitored).
1
Connect the contact sensor wires to either the CLOSE EDGE or
OPEN EDGE/PHOTO terminal on the control board.
• CLOSE EDGE: Will detect an obstruction while the gate is closing.
• OPEN EDGE/PHOTO: Will detect an obstruction while the gate is opening.
If the electrically activated edge sensor comes in contact with an obstruction while
the gate is closing/opening, the gate will stop and reverse direction for a short time.
The gate will remain in this position until another command is given. If the edge
sensor comes in contact with the obstruction a second time, the gate will stop and
reverse direction for a short time and the operator alarm will sound. The alarm will
sound (up to 5 minutes) and the operator will have to be reset before it will resume
normal operation.
Open Sensor on Wall
Open Sensor on Wall
Open Sensor on Gate
Close Sensor on Gate
TO REMOVE CHAMBERLAIN PHOTOELECTRIC SENSORS
1
Remove the photoelectric sensor wires from the terminal block.
2
Press the LEARN LIMITS button.
3
Toggle the reset switch.
» ENTRAPMENT PROTECTION DEVICES
CLOSE
EDGE
1
OPEN EDGE/
PHOTO
Close Sensor on Wall
• Locate entrapment protection devices to protect between moving gate and
RIGID objects, such as posts or walls.
NON-CONTACT SENSORS (12 VDC PHOTOELECTRIC SENSORS)
Photoelectric sensor model 50-220.
1
Connect the non-contact sensor wires to either the OPEN PHOTO or CLOSE
PHOTO terminal on the control board.
It is best to use failsafe photoelectric sensors. If a photoelectric sensor is not working
or loses power or the photo beam is permanently blocked, the photoelectric sensor
will stop ALL gate operation.
• CLOSE PHOTO: If the photoelectric sensor beam is broken while the gate is closing,
the gate will stop and reverse to the fully open position. The obstruction must be
cleared before the operator will resume normal operation.
• OPEN PHOTO: If the photoelectric sensor beam is broken while the gate is opening,
the gate will stop and stay in that position until the obstruction is cleared. Once the
obstruction is cleared the operator will resume normal operation.
NOTE: The OPEN EDGE/PHOTO terminal may be used as a secondary input for
photoelectric sensors (as in dual gate applications, when more than one OPEN
PHOTO is needed).
Property owners are obligated to test photoelectric sensors monthly.
OPEN EDGE/
PHOTO
OPEN
PHOTO
CLOSE
PHOTO
Entrapment Non-Contact Sensor
Safety Non-Contact Sensor
23
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite rsl12vh

Table of Contents