Storage Controllers; Perc H200; Perc H700; Perc H800 - Dell External OEMR R810 Technical Manual

Technical guide
Table of Contents

Advertisement

Dell
Config
Configs
Type
SSD/SAS
7
MSSR1/R1-X
RAID
8
MSSR1/R5-X
9
MSSR1/R10-X
12.6

Storage Controllers

82B
12.6.1

PERC H200

125B
The H200 SAS HBA is an expansion card that plugs into the dedicated internal SAS slot on Riser1. It
incorporates two four-channel 6Gb/s SAS IOCs for connection to SAS hard disk drives. It is designed in
a form factor that allows the same card to be used in other 11G 2U rack-form factor platforms.
12.6.2

PERC H700

126B
For customers who want a hardware RAID solution, the H700 is an option. This H700 card has its own
processor with a Gen2 PCI Express host interface and DDR2 memory and plugs into the dedicated
internal SAS slot on Riser1. A battery is also available for back-up. It supports the internal 6Gb/s SAS
backplane interface for internal storage options (SAS, SATA, or SSD HDD). The PowerEdge R810
supports both 256MB and 512MB cache options on the internal H700.
12.6.3

PERC H800

127B
R810 can support up to two PERC 800 adapter cards for access to external SAS direct-attach storage.
Features of the PERC H800 include:
LSI 2108 (Liberator) ROC
6Gb/s SAS
x8 PCIe Gen2
800Mz Core PPC
DDRII - 800MHz – mini-DIMM
512MB battery-backed write cache or 512MB or 1GB NV RAM-backed cache
Dual Mini-SAS Connectors
Dell PowerEdge R810 Technical Guide

Table 14. Mixed SSD and SAS RAID Configurations

Description
Integrated SSD/SAS RAID 1/RAID 1 (PERC
H700)
Integrated SSD/SAS RAID 1/RAID 5 (PERC
H700)
Integrated SSD/SAS RAID 1/RAID 10 (PERC
H700)
Mixed SSD/SAS
Min 2xSSD+2xSAS
2.5":Max 2xSSD + 4xSAS
Min
Max
2.5‖ = 2+2
2.5‖ = 2+2
2.5‖ = 2 + 3
2.5‖ = 2 + 4
2.5‖ = 2 + 4
2.5‖ = 2 + 4
48