Alliance Laundry Systems 1305 Supplement Manual
Alliance Laundry Systems 1305 Supplement Manual

Alliance Laundry Systems 1305 Supplement Manual

Ac adjustable frequency drive information
Table of Contents

Advertisement

Washer/Extractor
For Allen-Bradley Model Numbers:
PHM1396C
U073M
U073M
AC Adjustable Frequency
Drive Information
TMB1396C
160
1305
1336
PowerFlex 40
PowerFlex 400
F A
U L
U074M
U074M
T
R E
A D
Y
Part No. F232120R6
U072M
U072M
U071M
U071M
January 2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1305 and is the answer not in the manual?

Questions and answers

Ofer
February 18, 2025

Power flex 40 not powering washer motor need to reprogram

1 comments:
Mr. Anderson
February 18, 2025

To reprogram the PowerFlex 40 for an Alliance Laundry Systems washer motor that is not powering, follow these steps:

1. Reset to Factory Defaults:
- Set P041 = 1 (Reset to Defaults) to restore factory settings.
- This will reset all drive parameters, requiring reprogramming.

2. Check Parameter Lock:
- Ensure A101 = 0 (Parameters Unlocked) to allow modifications.

3. Verify Wiring and Connections:
- Check that drive-to-motor wires are damage-free, properly connected, and torqued.
- Ensure the control terminal “Enable” is correctly connected to “Common.”

4. Check Motor Overload and Torque:
- Monitor d030 (OL Level) to check for overload progression.
- Check d029 (Torque Current) to verify motor torque.

5. Inspect Control Inputs:
- Verify correct control signals are being sent.
- Refer to the applicable control input table in the manual.

6. Ensure No Mechanical Issues:
- Check for binding or motion restrictions in the washer basket.

After completing these steps, the drive should be reprogrammed, and the washer motor should function correctly.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Alliance Laundry Systems 1305

  • Page 1 Washer/Extractor AC Adjustable Frequency For Allen-Bradley Model Numbers: PHM1396C TMB1396C U073M U073M Drive Information 1305 1336 PowerFlex 40 PowerFlex 400 U074M U074M Part No. F232120R6 U072M U072M U071M U071M January 2010...
  • Page 3: Table Of Contents

    All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. F232120 © Copyright 2006, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT General Information... Nameplate Location...
  • Page 4 Supplement © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT Allen-Bradley 1336-Series AC Drives... 84 Installation/Wiring... 84 Input Power Conditioning... 84 Electrical Interference ... 85 Terminal Block Access ... 86 Power Terminal Block Description ... 87 Control Terminal Blocks Description and Control Logic...
  • Page 5: General Information

    Warnings specific to a particular subject will appear in the manual with the discussion of that subject. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT General Information CAUTION Only personnel familiar with the drive and...
  • Page 6: Nameplate Location

    160 NAMEPLATE LOCATION Figure 1 Nameplate Located on Bottom Portion of Chassis Behind Cover FRAMES A1, A2, A3, A4 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT U146ME3A U146ME3A 1336 PLUS NAMEPLATE LOCATION Figure 3 TMB1396C...
  • Page 7: General Inspection

    (i.e., loose parts, wires, connections, etc.) should be made. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT General Information Storage The drive should remain in its shipping container prior to installation.
  • Page 8: Powerflex 40 And 400 Drive Control Logic

    The stinger leg should be connected to the center Phase B on the reactor. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Input Power Conditioning The drive is suitable for direct connection to input power within the rated voltage of the drive.
  • Page 9: Electrical Interference

    C002501 and F8168701 C002502 and F8168702 C002507 and F8168705 C002502, F200309300 and F8168703 C002506, F200309400 and F8168704 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT INPUT POWER INPUT POWER W661 RFI Filter Part Number Information Drive Catalog...
  • Page 10: Terminal Block Access

    The drive utilizes a finger guard over the power wiring terminals. To remove: 1. Press in and hold the locking tab. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Opening the Cover 1. Press and hold in the tabs on each side of the cover.
  • Page 11: Power Terminal Block Description

    5.3 mm Max Wire Size 1.3 mm Min Wire Size Table 4 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 400 Input and Output Power Terminals (TB1) PowerFlex 400 PHM741N PowerFlex Power Block Terminal (TBI)
  • Page 12: Control Terminal Blocks Description And Control Logic

    “0” (logic 0). When the control input terminal voltage is low (active) the status will read “1” (logic 1). © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Balance Output The AC drive balance output signal is transmitted to the machine controller by the operation of an on-board normally open relay or transistor.
  • Page 13: Fault Code Display

    F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 40 and 400 Drive Control Logic 0-10V/0-20m A Switch The PowerFlex series of drives include a DIP switch that will allow the drive analog input signals to be wired as a 0-10V/0-20 mA switch.This switch should...
  • Page 14 0.5-0.8 N-m (4.4-7.0 lb-in) Max Wire Size 1.3 mm 0.13 mm Min Wire Size Table 7 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Stop Digital Common Digital Input 1 Digital Input 2 Digital Input 3...
  • Page 15 #1 Relay N.C. #2 Relay N.O. #2 Relay Common #2 Relay N.C. 10V 20mA F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Control Wiring Block Diagram 1 of 7 Digital Input Circuits +24V +10V Earth Referenced Frames D &...
  • Page 16 Distribution Speed 1 (ccw) Extract Speed 1 (ccw) Extract Speed 2 (ccw) Extract Speed 3 (ccw) Extract Speed 4 (ccw) Extract Speed 5 (ccw) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Digital Digital Digital Stop In 3...
  • Page 17 Very Low Extract (ccw) Low Extract (ccw) Medium Extract (ccw) High Extract (ccw) Very High Extract (ccw) F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 40 and 400 Drive Control Logic Digital Digital Digital Stop...
  • Page 18 *If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Digital...
  • Page 19 *If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 40 and 400 Drive Control Logic...
  • Page 20 *If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Digital...
  • Page 21 NOTE: IPH models use analog signals to control speed - refer to parameter d002 (command freq.) and d020 (analog input %) to verify speed input signal. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 40 and 400 Drive Control Logic 0 = No signal received...
  • Page 22 Terminals 17 thru 29 P/N F370577 WE-6 Output Board EDC OUTPUT BOARD P/N: 370433 EDC Output Board © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Figure 12 30 31 32 33 34 35 Figure 13 Drive...
  • Page 23 UNILINC, QUANTUM, GALAXY AND UNIMAC SOFTWARE OUTPUT BOARD P/N: F8108001 UniLinc Output Board A AND B-CONTROL OUTPUT BOARD F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 40 and 400 Drive Control Logic Figure 15 Drive Harness...
  • Page 24 PowerFlex 40 and 400 Drive Control Logic PS40 CONTROL OUTPUT BOARD Drive Harness Connection J11 PHM777N Figure 17 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 25 H2-8 H2-9 H2-10 H2-11 H2-12 Table 15 (continued) F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 40 and 400 Drive Control Logic Table 15 (continued) UniLinc Control– Output Board F8108001 H13-2 H13-3 H13-4 H13-5...
  • Page 26 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Parameter Description Output Displays instantaneous output frequency Frequency (in Hz). Command Displays command output frequency (in Frequency Hz).
  • Page 27 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 40 and 400 Drive Control Logic Table 16 (continued) Parameter Description Control Displays the AC drive's firmware Firmware version. For PowerFlex 40 drives, this Version will be 70.xx, 80.xx or 90.xx.
  • Page 28 A198 A152 A164 R261 A187 A188 R285 A192 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Table 16 (continued) Parameter Description Torque Current Displays the present value of the motor's torque current (in Amps). OL Level Displays the real-time motor overload progression (100% = F007 Fault).
  • Page 29 PowerFlex drive firmware. Refer to parameter d016 for the firmware's version. NOTE: All PowerFlex drives used in Alliance Laundry Systems' equipment are custom-developed with unique features and parameters. Parameter information provided within the Allen-Bradley PowerFlex series AC drive manual will differ and may not be relevant.
  • Page 30: Ac Drive Diagnostics/Parameter Viewing

    Run/Direction Steady Red Status Flashing Red © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Integral Keypad The integral keypad displays several main menu group selections such as “d”, “P”, and “A” as described below. Within the Display Group is a fault storage buffer that stores the last three AC drive fault codes.
  • Page 31 Description Basic Display Communications Advanced Display Basic Program F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 40 and 400 Drive Control Logic Menu Description Advanced Program Group. Consists of remaining programmable functions. Fault Designator. Consists of list of codes for specific fault conditions.
  • Page 32 Used to start the drive. Default is active. Controlled by parameters P036 (Start Source). Potentiometer Used to control speed of drive. Default is active. Controlled by parameter P038 (Speed Reference). © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT VOLTS AMPS HERTZ PROGRAM...
  • Page 33: Viewing And Editing Parameters

    Frequency) is displayed. Press Enter or Sel to enter the group menu. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 40 and 400 Drive Control Logic The following is an example of basic integral keypad and display functions.
  • Page 34: Fault Display And Troubleshooting Information

    Fault Indicator Light © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT When a fault occurs, the fault indicator light on the integral keypad will illuminate. The fault code will immediately be indicated on the display, such as “F005”.
  • Page 35: Allen-Bradley Drive Fault Codes

    Unable to Decelerate Max Retries Fault Phase U Fault F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley Drive Fault Codes Description DC Bus voltage remains below Monitor incoming AC line for low voltage or line power 85% nominal for longer than .5...
  • Page 36 VW Short Fault Reset to Default Values Software Over-current Drive Overload Parameter Checksum © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Table 20 (continued) Allen-Bradley Drive Fault Codes (continued) Description Phase to ground fault detected Check wiring between the drive and motor. Check for between controller and motor in grounded phase.
  • Page 37: Troubleshooting Suggestions

    6. Check control input signals. Refer to applicable table of inputs. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PowerFlex 40 and 400 Drive Control Logic Problem: Drive started but wash basket is not rotating.
  • Page 38: Allen-Bradley 160-Series Ac Drives

    The stinger leg should be connected to the center Phase B on the reactor. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Input Power Conditioning The drive is suitable for direct connection to input power within the rated voltage of the drive.
  • Page 39: Electrical Interference

    Figure 21 displays an electrical schematic for various RFI configurations. shows associated RFI filter part numbers. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 160-Series AC Drives CAUTION ELECTRIC SHOCK HAZARD! Service and maintenance to be performed only by an authorized technician.
  • Page 40 *Applies to *C 18–50 lb. models or *F 18–25 lb. models built before July 1999 with Series A or B drives. If Series A or B drive was replaced with a Series C drive, refer to the Series C section. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT RFI Filter Part Number Information...
  • Page 41: Terminal Block Access

    FAULT READY Ground 160 SERIES A & B Figure 22 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT W662 R/L1 S/L2 T/L3 BR- BR+ FAULT READY 1 2 3 4 5 6 7 8 9 1011...
  • Page 42: Power Terminal Block Description

    Option – Refer to instructions with option DC+, DC- Capacitor Module Option U, V, W (T1, T2, T3) Motor Connection Table 23 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Chassis Chassis R/L1 S/L2 T/L3 BR- BR+ FAULT READY...
  • Page 43: Control Terminal Blocks Description And Control Logic

    SW1, SW2, and SW3 in conjunction with STR and STF (direction) inputs. Refer to Figure 24 and Table 25. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 160-Series AC Drives Input Mode = “1” Parameter #46 Typical Configuration...
  • Page 44: 160 Series Drive Control Logic Chart

    High 1 Extract High 2 Extract High 3 Extract © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT To activate a control input (i.e., SW1, SW2, etc.), the terminal is connected to a common terminal (TB3-3 or TB3-7) to lower the signal voltage to a low condition (less than 1 Volt DC).
  • Page 45 Wash Speed Reverse Distribution Speed Medium Extract/Spray Rinse Extract Speed 1 Extract Speed 2 Extract Speed 3 (Default) Extract Speed 3 (Maximum) F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Terminal Terminal Terminal Terminal Terminal (SW3) (SW2)
  • Page 46 1/2 Wash Speed Forward 1/2 Wash Speed Reverse Wash Speed Forward Wash Speed Reverse Distribution Speed Spin 1 Spin 2 Spin 3 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Terminal Terminal Terminal Terminal Terminal (SW3) (SW2)
  • Page 47 Wash Speed Forward Wash Speed Reverse Distribution Speed Medium Extract High 1 Extract High 2 Extract High 3 Extract F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Terminal Terminal Terminal Terminal Terminal (SW3) (SW2) (SW1)
  • Page 48 NOTE: These models use analog signals to control speed – refer to parameter #6 (command freq.) and parameter #16 (analog input %) to verify speed input signal. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 0 = No signal received...
  • Page 49 This action occurs at distribution speed connecting TB3-10 and TB3-11 when the drive detects an acceptable balance condition. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 160-Series AC Drives CAUTION MACHINE DAMAGE AND/OR PERSONAL INJURY.
  • Page 50 Terminals 17 thru 29 P/N F370577 WE-6 Output Board EDC OUTPUT BOARD P/N: 370433 EDC Output Board © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Figure 25 30 31 32 33 34 35 Figure 26 Drive...
  • Page 51 A AND B-CONTROL OUTPUT BOARD PS40 CONTROL OUTPUT BOARD F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Figure 28 Drive Harness Connection J11 Figure 29 Allen-Bradley 160-Series AC Drives Drive Harness PHM776N Connection J11 PHM776N...
  • Page 52 EDC – Output Board P/N: F370433 H2-7 H2-8 H2-9 H2-10 H2-11 H2-12 Table 32 (continued) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Table 32 (continued) Output Board Terminal A and B-Control P/N: F0370448xx J11-1-8/STF J11-1-7/STR J11-1-6/RH J11-1-5/RM...
  • Page 53: Ac Drive Diagnostics/Parameter Viewing

    AC drive. Proceed with caution. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 160-Series AC Drives Installing the PKM 1. Remove power from the machine at main disconnect.
  • Page 54 (Figure 31). © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT PKM – Key Explanation Escape key. Use to return to last or original position.
  • Page 55 Up and Down arrow keys 6. To exit the Program Group, press the ESC key F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Display Mode Parameter Set Output Frequency Output Voltage...
  • Page 56: Copycat Keypad

    AC drive. Proceed with caution. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Remote Programming Adapter (RPA) Installation/Removal Installing the RPA 1.
  • Page 57: Connector Cable

    F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 160-Series AC Drives Removing the RPA 1. Remove power from machine at main disconnect.
  • Page 58 Press to select mode of operation or, in Edit mode, to cancel an edit sequence. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Select key. In Program mode, press to use Up or Down arrow keys to edit a parameter value.
  • Page 59: Selecting A Parameter

    (#30 – 86), press the Escape key until the Program LED lights. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 160-Series AC Drives 4. Enter the desired two-digit parameter number using the numeric keys.
  • Page 60: Fault Display And Troubleshooting Information

    Fault Fault Parameter Code © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Clearing Faults When a fault occurs, the cause must be corrected before the fault can be cleared. Resetting a fault will not correct the cause of the fault condition. After corrective action has been taken, simply cycling power to the drive will clear the fault.
  • Page 61: Allen-Bradley Drive Fault Codes

    EEPROM Fault Max Retries Fault Phase U Fault F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley Drive Fault Codes Description DC Bus voltage remains below Monitor incoming AC line for low voltage or line power 85% nominal for longer than 0.005...
  • Page 62 Phase W Fault UV Short Fault UW Short Fault VW Short Fault Reset to Default Values © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Table 34 (continued) Allen-Bradley Drive Fault Codes (continued) Description Phase to ground fault detected Check wiring between the drive and motor.
  • Page 63: Troubleshooting Suggestions

    2. Verify no mechanical problems exist (i.e., binding, motion restriction). 3. Check control input signals. Refer to applicable table of inputs. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 160-Series AC Drives Problem: Wash basket not accelerating properly. Corrective Action 1.
  • Page 64: Allen-Bradley 1305-Series Ac Drives

    The stinger leg should be connected to the center Phase B on the reactor. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Input Power Conditioning The drive is suitable for direct connection to input power within the rated voltage of the drive.
  • Page 65: Electrical Interference

    Disconnect power before opening any access panels. Drive P/N 370815 370815 370816 370818 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT INPUT POWER INPUT POWER W661 RFI Filter Part Number Information Drive Catalog...
  • Page 66: Terminal Block Access

    Retaining Lever S t o Hinged Panel .0 0 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 2. Lower hinged panel located below HIM or blank front cover. 3. For drives equipped with a blank front panel, slide panel downward and remove it from drive.
  • Page 67: Power Terminal Block Description

    M3.5 1.5/0.20 (14/24) Table 38 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Control Terminal Blocks Description and Control Logic Control terminal functions are unique to each Allen- Bradley Drive. Each drive’s control terminal is addressed independently.
  • Page 68 NOTE: Verify that inputs are jumpered. Wire or metal clip jumpers may be used and can be easily overlooked during a replacement. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT CAUTION MACHINE DAMAGE AND/OR PERSONAL INJURY. Never jumper inputs if not...
  • Page 69 Switch 1/2 Wash Relay On Some Machines Jumper Balance Switch or Drive Interlock Relay Jumper or Motor Overtemp Switch F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Typical Configuration 1305 Drive Hardware Output Balance Detection...
  • Page 70: Maximum Torque

    High 2 Extract High 3 Extract Control Terminal (TB2) Torque Specifications Max/Min Wire Size Maximum Torque 1.5/0.20 (14/24) Table 41 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Stop Terminal Terminal Terminal Terminal Terminal (SW3) (SW2)
  • Page 71 1/2 Wash Speed Forward 1/2 Wash Speed Reverse Wash Speed Forward Wash Speed Reverse Distribution Speed Spin 1 Spin 2 Spin 3 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Stop Terminal Terminal Terminal Terminal Terminal (SW3) (SW2)
  • Page 72 Half-Wash Speed Reverse Wash Speed Forward Wash Speed Reverse Distribution Speed Medium Extract High 1 Extract High 2 Extract High 3 Extract © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Stop Terminal Terminal Terminal Terminal Terminal (SW3)
  • Page 73 Terminals 17 thru 29 WE-6 Output Board P/N F370577 EDC OUTPUT BOARD P/N: 370433 EDC Output Board F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Figure 41 30 31 32 33 34 35 Figure 42 Drive Control...
  • Page 74 V-Control F370314, F8206501 and F370447-6, etc. WE-6 Interface Board P/N: F370577, F0370446-xx J2A-30 J2A-31 J2A-32 J2A-33 J2A-34 J2A-35 EDC – Output Board P/N: F370433 H2-7 H2-8 H2-9 H2-10 H2-11 H2-12 Table 44 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT F232120...
  • Page 75: Ac Drive Diagnostics/Parameter Viewing

    Delay approximately three minutes. 2. Lower the hinged panel located below the HIM. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 1305-Series AC Drives 3. Slide blank panel cover toward base of drive and remove it.
  • Page 76 Stopped +0.00 Hz Human Interface Module (HIM) Figure 45 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT HIM – Key Explanation Escape key. Use to return to last or original position. Select key. Use to move cursor position.
  • Page 77: Him Structure Chart - Series A 3.00, Series B 1.01 Or Later Versions

    Output Current Output Voltage Output Power DC Bus Voltage Output Freq Freq Command Heatsink Temp Last Fault F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT OPERATOR LEVEL MODE LEVEL Program EEProm Search GROUP LEVEL Advanced Frequency...
  • Page 78: Him Structure Chart - Earlier Versions

    Output Current Output Voltage Output Power DC Bus Voltage Output Freq Freq Command Heatsink Temp Last Fault © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT OPERATOR LEVEL MODE LEVEL Program EEProm Password MAIN FILE Advanced Frequency...
  • Page 79 Choose Mode Display 5. Use the Up and Down arrow keys select “Display” if not displayed immediately. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 6. Press the Enter key Display will read: Choose Group Metering For earlier HIM versions, press the Enter key 7.
  • Page 80 Choose Mode Display 5. Use the Up and Down arrow keys select “Display” if not displayed immediately. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 6. Press the Enter key Display will read: Choose Group Faults For earlier HIM versions, press the Enter key 7.
  • Page 81 Display 5. Use the Up and Down arrow keys select “Display” if not displayed immediately. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 6. Press the Enter key Display will read: Choose Group Linear List For earlier HIM versions, press the Enter key 7.
  • Page 82: Fault Display And Troubleshooting Information

    Cross reference the number in Table 45 for fault identification and possible corrective action. Serial Fault In addition, A-B 1305 fault codes are stored in a fault buffer with the capability to store up to four fault codes. If more than four faults are identified, the least recent fault is deleted to make room for the additional fault.
  • Page 83: Allen-Bradley Drive Fault Codes

    EEPROM Fault Max Retries Fault Phase U Fault F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley Drive Fault Codes Description DC Bus voltage remains below Monitor incoming AC line for low voltage or line power 85% nominal for longer than .5...
  • Page 84 UW Short Fault VW Short Fault IPM Current Fault IPM Overtemp Fault Reset to Default Values © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Table 45 (continued) Allen-Bradley Drive Fault Codes (continued) Description Phase to ground fault detected Check wiring between the drive and motor.
  • Page 85: Troubleshooting Suggestions

    2. Verify no mechanical problems exist (i.e., binding, motion restriction). 3. Check control input signals. Refer to applicable table of inputs. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 1305-Series AC Drives Problem: Wash basket not accelerating properly. Corrective Action 1.
  • Page 86: Allen-Bradley 1336-Series Ac Drives

    The stinger leg should be connected to the center Phase B on the reactor. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Input Power Conditioning The drive is suitable for direct connection to input power within the rated voltage of the drive.
  • Page 87: Electrical Interference

    Drive P/N 370838 370838 370835 370837 370834 370828 370825 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT INPUT POWER INPUT POWER W661 RFI Filter Part Number Information Drive Catalog Machine Voltage 1336-AQF50...
  • Page 88: Terminal Block Access

    S to .0 0 TB2 TB1 Front Cover © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT To access the power and control terminal blocks, perform the following procedure: 1. Remove power from machine at main disconnect. Verify power light is off.
  • Page 89: Power Terminal Block Description

    DC Bus Terminals U (T1), V (T2), W (T3) Motor Connection Table 48 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Frame 380-480V, 5.5 Ð 7.5 kW (7.5 Ð 10 HP) Terminal Designations GRD GRD (T1)
  • Page 90: Control Terminal Blocks Description And Control Logic

    (less than 1 Volt DC). © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT The Input Status’ display of 1s and 0s represents the drive’s display of parameter #55. These inputs can be viewed in the status display with a Human Interface Module (HIM or parameter unit).
  • Page 91 “0”, a jumper is missing or an over-temp condition exists with the motor. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 1336-Series AC Drives Fault Indicator Light The A-B 1336 is equipped with a mechanical relay which transitions when a drive fault occurs.
  • Page 92 Allen-Bradley 1336-Series AC Drives Jumper, Balance Switch or drive interlock relay Jumper or motor overtemp switch © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Input Mode =“12” Parameter #21 Typical Configuration Washer-Extractor Control Hardware Resistor Potentiometer...
  • Page 93 Common 28, 29 27, 29 26, 29 Common Enable 30, 29 Table 50 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Torque Specifications Max/Min Wire Size Machine Use Not Used 2.1/0.3 (14/22) Select Machines Only...
  • Page 94 Medium Extract/Spray Rinse High Extract Speed 1 High Extract Speed 2 High Extract Speed 3 (Default) High Extract Speed 3 (Maximum) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Terminal Terminal Terminal Terminal Terminal (SW2) (SW1)
  • Page 95 Wash Speed Forward Wash Speed Reverse Distribution Speed Medium Extract High 1 Extract High 2 Extract High 3 Extract F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Stop Terminal Terminal Terminal Terminal Terminal (SW2) (SW1)
  • Page 96 1/2 Wash Speed Forward 1/2 Wash Speed Reverse Wash Speed Forward Wash Speed Reverse Distribution Speed Spin 1 Spin 2 Spin 3 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Stop Terminal Terminal Terminal Terminal Terminal (SW2)
  • Page 97 WE-6 INTERFACE BOARD Terminals 1 thru 16 Terminals 17 thru 29 P/N F370577 WE-6 Output Board F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 1336-Series AC Drives Drive Control Connections Figure 51 Drive Control...
  • Page 98 Allen-Bradley 1336-Series AC Drives UNILINC OUTPUT BOARD P/N: F8108001 UniLinc Output Board © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Figure 53 Drive Harness Connection PHM738N F232120...
  • Page 99 WE-6 Interface Board P/N: F370577, F0370446-xx J2A-30 J2A-31 J2A-32 J2A-33 J2A-34 J2A-35 UniLinc Control– Output Board F8108001 H13-2 H13-3 H13-4 H13-5 H13-6 H13-7 Table 55 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 1336-Series AC Drives...
  • Page 100: Ac Drive Diagnostics/Parameter Viewing

    HIM. Slide HIM downward and remove it from drive. 4. Replace front cover. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT External HIM Connection The HIM unit can be installed using an adapter cable (P/N P370716). This method of attaching the HIM uses an external connector shown in Figure 54.
  • Page 101 Stopped +0.00 Hz Human Interface Module (HIM) Figure 55 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 1336-Series AC Drives HIM – Key Explanation Escape key. Use to return to last or original position.
  • Page 102: Him Structure Chart - Series A 3.00, Series B 1.01 Or Later Versions

    Output Current Output Voltage Output Power DC Bus Voltage Output Freq Freq Command Heatsink Temp Last Fault © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT OPERATOR LEVEL MODE LEVEL Program EEProm Search GROUP LEVEL Advanced Frequency...
  • Page 103: Him Structure Chart - Earlier Versions

    Output Current Output Voltage Output Power DC Bus Voltage Output Freq Freq Command Heatsink Temp Last Fault F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT OPERATOR LEVEL MODE LEVEL Program EEProm Password MAIN FILE Advanced Frequency...
  • Page 104 Choose Mode Display 5. Use the Up and Down arrow keys select “Display” if not displayed immediately. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 6. Press the Enter key Display will read: Choose Group Metering For earlier HIM versions, press the Enter key 7.
  • Page 105 Choose Mode Display 5. Use the Up and Down arrow keys select “Display” if not displayed immediately. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 6. Press the Enter key Display will read: Choose Group Faults For earlier HIM versions, press the Enter key 7.
  • Page 106 Choose Mode Display 5. Use the Up and Down arrow keys select “Display” if not displayed immediately. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 6. Press the Enter key Display will read: Choose Group Linear List For earlier HIM versions, press the Enter key 7.
  • Page 107: Fault Display And Troubleshooting Information

    HIM as shown below. Refer to HIM installation and operation. Fault Buffer 0 F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 1336-Series AC Drives The fault parameters are identified as follows: “Last Fault”...
  • Page 108 Fault Indicator Light DC Bus Charge Light © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Fault Indicator Light Figure 56 U143ME3A...
  • Page 109: Allen-Bradley Drive Fault Codes

    EEPROM Fault Max Retries Fault Phase U Fault F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley Drive Fault Codes Description The motor thermal switch path is Motor temperature high. Check for: ambient air, cooling open.
  • Page 110 UV Short Fault UW Short Fault VW Short Fault Ground Warning Reset to Default Values © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Table 56 (continued) Allen-Bradley Drive Fault Codes (continued) Description Phase to ground fault detected Check wiring between the drive and motor.
  • Page 111: Troubleshooting Suggestions

    2. Verify no mechanical problems exist (i.e., binding, motion restriction). 3. Check control input signals. Refer to applicable table of inputs. F232120 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Allen-Bradley 1336-Series AC Drives Problem: Wash basket not accelerating properly. Corrective Action 1.