Fw 07.01.02/hafm sw 08.06.00 hp storageworks ha-fabric manager release notes (aa-rur6g-te, august 2005)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:

Advertisement

Zoning change RSCN control
Normally, when a zone set is activated, a fabric format domain Register State Change
Notification (RSCN) is sent to all devices in the fabric. With firmware 05.00.00 or later,
you can disable these RSCNs from being sent. This is done using the Suppress RSCNs
on zone set activations check box on the Configure Switch Parameters dialog box.
This feature significantly changes the normal behavior of the fabric. Devices will have no
warning when zones change and will not automatically update their zoning information.
The ability to suppress RSCNs is disabled (check box is not selected) by default. This
feature can be configured through HAFM, EWS, and CLI.
SNMP changes
Firmware 07.01.02-4 supports the following management information base (MIB)
versions on all products:
Fabric Element MIB: 1.1
MIB-II MIB: RFC-1213, non-implemented sections are not included
FCEOS MIB: 2.0
SNMP Framework MIB: RFC-2271 (1997/09/30)
FA MIB: 3.0
FA MIB: 3.1
SNMP requests can be received in either 3.0 or 3.1 of the Fibre Alliance (FA) MIB, and
the switch responds in the same version. The switch can also be configured to use a
specific version for traps generated by the switch.