Ups - D-Link DSN-6020 User Manual

10gbe iscsi to sata ii / sas raid ip san storage
Hide thumbs Also See for DSN-6020:
Table of Contents

Advertisement

If "Auto shutdown" is checked, the system will shutdown automatically when voltage or
temperature is out of the normal range. For better data protection, please check "Auto
Shutdown".
For better protection and avoiding single short period of high temperature triggering auto
shutdown, the system use multiple condition judgments to trigger auto shutdown, below
are the details of when the Auto shutdown will be triggered.
1.
There are several sensors placed on systems for temperature checking. System will
check each sensor for every 30 seconds. When one of these sensor is over high
temperature threshold for continuous 3 minutes, auto shutdown will be triggered
immediately.
2.
The core processor temperature lim it is 80℃. The iSCSI NI C tem perature lim it is 65℃.
The SAS expandor and SAS controller tem perature lim it is 65℃.
3.
If the high temperature situation doesn't last for 3 minutes, system will not trigger
auto shutdown.
4.5.2

UPS

"UPS" can set up UPS (Uninterruptible Power Supply).
(Figure 4.5.2.1: Without UPS.)
Currently, the system only supports and communicates with smart-UPS of APC (American
Power
Conversion
http://www.apc.com/.
First, connect the system and APC UPS via RS-232 for communication. Then set up the
shutdown values (shutdown battery level %) when power is failed. UPS in other
companies can work well, but they have no such communication feature with the system.
Figure 4.5.2.1
Corp.)
UPS.
Please
review
the
details
76
from
the
website:

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsn-640Dsn-6410Dsn-654Dsn-6420Dsn-6410w/640

Table of Contents