Key Dimensions And Specifications; Location Requirements; Choose The Proper Location; Clearances - Kenmore 8027 - 7.3 cu. Ft. Electric Dryer Use And Care Manual

Use and care guide
Table of Contents

Advertisement

Available languages

Available languages

I
I
KEY DIMENSIONS
AND SPECIFICATIONS
Description
Dryer (Gas and Electric)
Electrical Requirements
Please refer to the rating label.
Gas Requirements*
NG:
6-8 in. WC
Gas Requirements*
LP:
10-13 in. WC
Dimensions
27" (W) X 28 11/16" (D) X 38" (H), 49 5/6" (D With door open)
68.6cm (W) X 73.0cm (D) X 96.5cm (H),126.4cm (D With door open)
Net Weight
126 lb. (57.2 kg)
Drying Capacity
796.8002#9##
/ 796.9002#9##:
IEC 7.1 cu. ft.
796.8027#9##/796.9027#9##:
IEC 7.3 cu. ft.
*Gas Models only.
LOCATION REQUIREMENTS
IMPORTANT:
Read all installation instructions completely before
installing and operating your dryer!
It is important that you review this entire manual before
installing and using your dryer. Detailed instructions
concerning electrical connections,
gas connections,
and exhaust requirements
are provided on the
following pages.
CHOOSE THE PROPER LOCATION
• Store and install the dryer where it will not be exposed
to temperatures below freezing or exposed to outdoor
weather conditions.
• Choose a location with a solid, level floor.
• If the dryer is being installed in a garage, place the
dryer at least 18 in. (46 cm) above the floor.
• Properly ground the dryer to conform with all governing
codes and ordinances.
• To reduce the risk of electric shock, do not install
the dryer in damp or wet locations.
IMPORTANT: If you are installing your dryer in a
manufactured or mobile home, please refer to the
section Special Requirements
for Manufactured
or Mobile Homes on page 12.
CLEARANCES
• Most installations require a minimum 5 1/2 in.
(14 cm) clearance behind the dryer for
the exhaust ducting.
• Allow minimum clearances of at least 1 in.
(2.5 cm) on the sides and back to minimize
vibration and noise.
• Allowing additional clearance for installation
and servicing is recommended.
• Be sure to allow for wall, door, or floor moldings
that may increase the required clearances.
• Allow at least 21 in. (53.3 cm) in front of the dryer
to open the door.
!
20"
(50.8 cm)
3 II
(7.6 cm)
i
J
48 in.2
(310 cm)
34 in. 2
(155 cm) \
'
'
' '
'
_11
I
4" _11-_,_28
11/16''-_
I-_
(10 cm)
(73.0 cm) _
(10 cm)
49 5/6"
(126.4 cm)
iO
I
1 ii
oo
(2.5 cm)
-_11_
1 ii
27"
_ _- (2.5 cm)
(68.6 cm)
Additional Instructions for
closet installations:
• The closet door must allow
for sufficient airflow. Refer to
the diagram to the left for
minimum vent opening
requirements. A Iouvered
door is also acceptable.
Closet Door Vent
3"
Requirements
(7.6 cm)
8
I
I