Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire
(white or center wire) of power supply cord under center,
terminal block screw. Tighten screw.
B
C
A
E
s""/i
A. External ground conductor screw - Dotted fine shows
position of NEUTRAL ground wire before being moved
to center terminal block screw.
B. Center terminal block screw
C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief
E. Neutral ground wire
Connect ground wire (green or bare) of power supply cord
to external ground conductor
screw. Tighten screw.
J
F
E
D
A. External ground conductor screw
B. Center terminal block screw
C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief
E. Ground wire (green or bare) of power supply cord
F. Neutral ground wire
Connect the other wires to outer terminal block screws.
Tighten screws.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connections.
Now go
to "Venting Requirements."
4-wire connection:
Direct Wire
IMPORTANT: A 4-wire connection
is required for mobile
homes and where local codes do not permit the use of
3-wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving
bare ground wire at 5" (127 mm). Cut 11/2"(38 mm) from
3 remaining wires. Strip insulation back 1" (25 mm). Shape ends
of wires into a hook shape.
(127
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
1=
2.
Remove center terminal block screw.
Remove neutral ground wire from external ground
conductor screw. Connect neutral ground wire and place
the hooked end (hook facing right) of the neutral wire (white
or center wire) of direct wire cable under the center screw
of the terminal block. Squeeze hooked ends together.
Tighten screw.
A
B
-m
/////¢
O
//
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved
to center terminal block screw.
B. Center terminal block screw
C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief
E. Neutral ground wire