Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire} to center
terminal.
Ground wire (green or bare wire} must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold}.
Securely tighten
all electrical
connections.
Failure to do so can result in death, fire, or
electrical
shock.
Direct Wire
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire} to center
terminal.
Ground wire (green or bare wire} must be connected to
green ground connector=
Connect remaining
2 supply wires to remaining
2 terminals
(gold}.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect
power.
2. Remove the hold-down screw and terminal block cover.
A
B
C
D
Style 1: Power supply cord strain relief
Remove the screws from a 3/4" (19 mm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws enough to hold the two clamp sections together.
A. Terminal block cover
B. External ground conductor screw
C. Center terminal block screw
D. Hold-down
screw location
E. Neutral ground wire
F. Hole below terminal block opening
3. Install strain relief.
,.
o
A. Strain relief tab pointing
up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing
down
Put power supply cord through the strain relief. Be sure
that the wire insulation on the power supply cord is inside
the strain relief. The strain relief should have a tight fit with
the dryer cabinet and be in a horizontal position. Do not
further tighten strain relief screws at this point.