Replacing The Serveraid Sas Controller - IBM 7979B1U User Manual

User manual
Hide thumbs Also See for 7979B1U:
Table of Contents

Advertisement

Replacing the ServeRAID SAS controller

A ServeRAID SAS controller can be installed only in a dedicated slot on the system
board. The server comes with a ServeRAID-8k-l SAS Controller installed.
Note: The ServeRAID-8k-l SAS Controller does not have a battery.
To replace the ServeRAID-8k-l SAS Controller with a ServeRAID-8k SAS Controller,
complete the following steps:
46
System x3650 Type 7979: User's Guide
1. Read the safety information that begins on page vii and "Installation guidelines"
on page 28.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables (see "Turning off the server" on page 13).
Attention:
In a dc power environment, only trained service personnel other
than IBM service technicians are authorized to connect or disconnect power to
the dc power supply. See the documentation that comes with each dc power
supply.
3. Remove the cover (see "Removing the cover" on page 31).
4. Remove the riser-card assembly and the air baffle over the DIMMs (see
"Removing the DIMM air baffle" on page 36).
5. Locate the ServeRAID-8k-l SAS controller on the system board.
Attention:
To avoid breaking the retaining clips or damaging the connectors,
handle the clips gently.
6. Open the retaining clip on each end of the connector.
7. Lift the ServeRAID-8k-l SAS controller out of the connector.
8. Touch the static-protective package that contains the new ServeRAID-8k SAS
controller to any unpainted metal surface on the server. Then, remove the
ServeRAID-8k SAS controller from the package.
Battery cable
RAID controller
Battery
Battery mounting
tabs
Battery mounting
clips
Battery cable
connector

Hide quick links:

Advertisement

Table of Contents
loading