Array Controllers With Extended Scsi - Compaq ProLiant 8000 Maintenance And Service Manual

Proliant 8000 servers maintenance and service guide
Hide thumbs Also See for ProLiant 8000:
Table of Contents

Advertisement

2-64 Compaq ProLiant 8000 Servers Maintenance and Service Guide

Array Controllers with Extended SCSI

To remove any array controller with Extended SCSI architecture:
1. Unlock then open the PCI Hot Plug access doors. See "I/O Expansion Slots" earlier in
this chapter.
2. Deactivate the expansion board slot LED by pressing the square button on the
PCI switchboard
3. When the green LED is off, push down on the slot release lever
free the array controller.
4. Slide the slot keeper
4
Figure 2-58. Releasing an array controller with Extended SCSI
.

CAUTION: Do not open the slot release lever unless the green PCI Hot Plug LED indicator for
the slot is off. System power down and subsequent data loss could occur. Never remove an
active controller unless it is redundant.
to the open position.

then push it back

2
1
3
to


Advertisement