1100 - 1199, Serial Test Error Codes; 1200 - 1299, Modem Communications Test Error Codes - Compaq ProLiant 8000 Maintenance And Service Manual

Proliant 8000 servers maintenance and service guide
Hide thumbs Also See for ProLiant 8000:
Table of Contents

Advertisement

6-40 Compaq ProLiant 8000 Servers Maintenance and Service Guide
1100 – 1199, Serial Test Error Codes
The 1100 series of diagnostic error codes identifies failures with serial/parallel interface board
or system board functions.
Error Code
1101-xx
1109-xx
1200 – 1299, Modem Communications Test Error Codes
The 1200 series of diagnostic error codes identifies failures with the modem.
Error Code
1201-xx
1202-xx
1203-xx
1204-xx
1206-xx
1210-xx
Serial Test Error Codes
Description
Serial port test failed.
Clock register test failed.
Modem Communications Test Error Codes
Description
Modem internal loopback test
failed.
Modem time-out test failed.
Modem external termination test
failed.
Modem auto originate test failed.
Dial multi-frequency tone test
failed.
Modem direct connect test failed.
Table 6-9
Recommended Action
The following steps apply to error codes 1101-xx
through 1109-xx.
1.
Check the switch settings on the serial/parallel
interface board (if applicable) and retest.
2.
Replace the serial/parallel interface board
(if applicable) and retest.
3.
Replace the system board and retest.
Table 6-10
Recommended Action
The following steps apply to error codes 1201-xx
through 1210-xx.
1.
Refer to the modem documentation for correct
setup procedures and retest.
2.
Check the modem line and retest.
3.
Replace the modem and retest.