6-18 Compaq ProLiant 8000 Servers Maintenance and Service Guide
Table 6-2
POST Error Messages
Error Code
1613-Low System
Battery
1615-Power Supply
configuration error
1615-Power Supply
Failure, Power
Supply Unplugged, or
Power Supply Fan
Failure in Bay X
1617-Fan controller
not responding.
System halted.
1617-I/O Fan
controller not
responding.
System halted
1617-CPU Fan
controller not
responding.
System halted
1618-PCI slots
powered down.
Check PCI hot plug
enabler connectors.
1620-Locked SCSI
Bus Detected. Verify
SCSI bus cabling.
System halted.
1621-Current SCSI
bus cable
configuration is not
recommended
continued
Audible Beeps
Probable Source of Problem
None
Real time clock system battery is
running low on power.
None
Your configuration requires an
additional power supply. A
moving bar will display, to
indicate that the system is
waiting for another power supply
to be installed.
None
A power supply has failed.
2 short
Fan controller failure detected.
2 short
I/O fan controller failure detected.
2 short
CPU fan controller failure
detected.
None
PCI hot plug enabler is missing or
failed.
None
SCSI bus failure detected.
None
Improper SCSI bus cabling
detected.
Recommended Action
Replace battery (or add external
battery) as soon as possible.
Install the additional power
supply.
Reseat power supply firmly.
-Or-
Replace power supply as soon
as possible.
Check and replace failed
controller assembly.
Check and replace failed
controller assembly.
Check and replace failed
controller assembly.
Check and replace missing or
failed assembly.
Ensure that the integrated SCSI
controller has SCSI termination
attached.
Check documentation for proper
SCSI bus cabling.
continued