4.4.3
Cleaning Roller Sensor (CRS)
1) Disconnect the harnesses connected to the cleaning roller sensor.
2) Remove the cleaning roller sensor from the paper exit guide (paper exit stay).
4.4.4
Discharger Brush
1) Remove the set screws BT4X6 (2 pcs.) from the discharger brush.
2) Remove the discharger brush and the plastic retainer.
Do not deform the fur brush of the discharger brush.
Discharger Brush
Cleaning Roller Sensor
Paper exit guide
Fig.7-60
PRECAUTION
Plastic retainer
Fig.7-61
VII-36
Paper exit guide