Driver Parameters; A.1.5 Driver Parameters - Novell IDENTITY MANAGER 3.6.1 - WORKORDER DRIVER IMPLEMENTATION GUIDE 18-12-2009 Implementation Manual

Workorder driver implementation guide
Table of Contents

Advertisement

Option
Disabled
Do not automatically
synchronize the driver

A.1.5 Driver Parameters

The Driver Parameters section lets you configure the driver-specific parameters. When you change
driver parameters, you tune driver behavior to align with your network environment. For example,
you might find the polling interval to be shorter than you need. Making the interval longer could
improve network performance while still maintaining your performance expectations for work order
processing.

Driver Parameters

Table A-5
Option
Driver Name
WorkOrders Container
Poll Interval
Poll Time
46
Identity Manager 3.6.1 WorkOrder Driver Implementation Guide.
Description
The driver has a cache file that stores all of the events. When the driver is set
to Disabled, this file is deleted and no new events are stored in the file until the
driver state is changed to Manual or Auto Start.
This option only applies if the driver is deployed and was previously disabled. If
this is not selected, the driver re-synchronizes the next time it is started.
Description
The actual name you want to use for the driver.
The name of the container where WorkOrder
objects and WorkToDo objects are to be stored.
How often the Publisher channel polls the
WorkOrder container for work orders to be
configured. The default is one minute. You can use
this setting, not use this setting, or use it with the
Poll Time setting. If you don't want to use this
setting, leave the field empty.
Time of day the Publisher channel checks the
WorkOrder container for work orders to be
configured. By default, this setting is disabled (No
poll time) so that only the Poll Interval setting is
used. However, you can use this setting instead of
the Poll Interval setting, or you can use it with the
Poll Interval setting.
The poll times are available in half-hour increments.
If you need a more granular poll time (for example,
1:15 PM rather than 1:00 PM or 1:30 PM), click the
Edit XML button, locate the
display-name="Poll Time" id="112"
name="polling-time" type="enum">
and change the type from
OK to save the change, then enter the desired time
in the Poll Time field. Use the
(for example, 1:15 PM).
<definition
entry,
enum
to
string
. Click
format
HH:MM AM/PM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDENTITY MANAGER 3.6.1 - WORKORDER DRIVER IMPLEMENTATION GUIDE 18-12-2009 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Identity manager 3.6.1

Table of Contents