Download Print this page
Renogy 1000w Manual
Renogy 1000w Manual

Renogy 1000w Manual

Battery power inverters
Hide thumbs Also See for 1000w:

Advertisement

Quick Links

User Manual of Product 1:
Amazon Basics 16-Pack Rechargeable AAA NiMH
High-Capacity Batteries, 850 mAh, Recharge up to 500x Times,
Pre-Charged
User Manual of Product 2:
Amazon Basics Battery Charger for AA & AAA Nickel-Metal
Hydride batteries (Ni-MH) With USB Port

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1000w and is the answer not in the manual?

Questions and answers

Summary of Contents for Renogy 1000w

  • Page 1 User Manual of Product 1: Amazon Basics 16-Pack Rechargeable AAA NiMH High-Capacity Batteries, 850 mAh, Recharge up to 500x Times, Pre-Charged User Manual of Product 2: Amazon Basics Battery Charger for AA & AAA Nickel-Metal Hydride batteries (Ni-MH) With USB Port...
  • Page 2 BATTERY POWER INVERTERS 12V Pure Sine Wave Inverter Manual 700w 1000w 2000w 3000w Version 1.4...
  • Page 3 Important Safety Instructions Please save these instructions. This manual contains important safety, installation, and operating instructions for the invert- er. The following symbols are used throughout the manual: Indicates a potentially dangerous condition. Use extreme caution WARNING when performing this task. Indicates a critical procedure for safe and proper operation of the CAUTION inverter.
  • Page 4 Battery Safety Do NOT let the positive (+) and negative (-) terminals of the battery touch each other. Use only sealed lead-acid, flooded, lithium battery, ryor gel batteries which must be deep cycle. Explosive battery gases may be present while charging. Be certain there is enough ventilation to release the gases.
  • Page 5 Table of Contents General Information Included Components Identification of Parts (AC Side) Identification of Parts (DC Side) Installation Location Recommendations Sizing a Battery Bank Grounding DC Side Connection AC Side Operation Inverter Troubleshooting External Fusing Specifications Dimensions 700W 1000W 2000W 3000W...
  • Page 6 Build-in 5V/2.1A USB port Pure Sine Wave The Renogy Power Inverters output a pure sine wave similar to the waveform of the grid power. In a pure sine wave, the voltage rises and falls in a smooth fashion with very low harmonic distortion and cleaner utility-like power.
  • Page 7 Included Components The Renogy Pure Sine Wave Battery Inverters will be shipped with inverter cables and a space for powering the inverter on or off. Inverter Model Gauge 700W 6 AWG 3ft 1000W 4 AWG 3ft 2000W 4 AWG*2 3ft...
  • Page 8 Identification of Parts (AC Side) 2 3 4 Figure 2: 1000W Inverter Key Parts 1.High Output AC Terminals (30A) — These terminals are for connecting 115V A C devices that require more than 15 amps to operate or for connection to distributed wiring that has multiple AC outlets.
  • Page 9 AC Outlets (15A) — 115V AC 60Hz, up to 15amps for 2000W and 3000W models, up to 6.1 amps for 700W,up to 8.7 amps for 1000W. USB Power Port — 5 volts / 2.1A for charging tablets, smartphones, and other small electronic devices.
  • Page 10 Identification of Parts (DC Side) 0.16inch (4mm) Figure 3: 3000W Inverter You are advised to select a wire diameter corresponding to a copper nose that NOTE is less than or equal to 4mm. KEY PARTS 1.Positive Terminal — Positive (+) DC Input (Red) 2.Cooling Fans —...
  • Page 11 Installation Make sure inverter is in the off position before connecting anything. WARNING Do not over-torque or over tighten the terminals. This could CAUTION potentially damage the unit. Refer to the technical specifications for max wire sizes on the CAUTION controller and for the maximum amperage going through wires.
  • Page 12 Utilize the formula Watts = Volts * Amps Determine Amps used for how many hours – Amp-hour (Ah) For this Renogy inverter, the battery bank will be 12 volts direct current (12 VDC) Example A Microwave oven...
  • Page 13 Be careful of the positive and negative poles. Reversing the poles might CAUTION cause permanent damage to the inverter. It will surely blow the internal fuse. Damage to the Renogy inverters due to reverse polarity is NOT covered by NOTE warranty.
  • Page 14 1.Flip inverter power to OFF position (on 2.Remove Cap, then unscrew inverter AC side) terminals and connect battery connections. Then tighten. For your safety, it is recommended to use a battery fuse. RNG-INVT-700- RNG-INVT-1000- RNG-INVT-2000- RNG-INVT-3000- Model 12V-P2 12V-P2 12V-P2 12V-P2 Continuous Output 700 W...
  • Page 15 Operation Assuming proper battery connection, the inverter is now ready for use. AC Side Operation 1.Connect electronic devices to electrical socket (s) on inverter. Flip inverter power to ON position (on AC side) 2.When finished, switch AC devices off FIRST, then turn off inverter switch Avoid switching on the inverter with the load (electronic devices) already CAUTION...
  • Page 16 Risk of electric shock. Use only class A ground-fault circuit-interrupter WARNING [receptacle (s) or circuit breaker(s)]. Other types may fail to operate properly when connected to this unit. GFCIs shall be installed in a recreational vehicle’s wiring system to protect all CAUTION branch circuits.
  • Page 17 Inverter Troubleshooting Indicator Potential Issue Troubleshoot Input voltage is below 10.5V Keep input voltage above 10.5V Alarm beeps Keep input voltage below 16.0V Input voltage is above 16.0V Input voltage is below 10V Keep input voltage above 10V Input voltage is above 16.5V Keep input voltage below 16.5V Allow inverter to cool down Fault LED Lit, inverter...
  • Page 18 External Fusing Fusing is a recommended in PV systems to provide a safety measure for connections going from panel to controller and controller to battery. Remember to always use the recommend- ed wire gauge size based on the PV system and the controller. NEC Maximum Current for different Copper Wire Sizes #AWG Max.
  • Page 19 Specifications RNG-INVT-700- RNG-INVT-1000- RNG-INVT-2000- RNG-INVT-3000- Model 12V-P2 12V-P2 12V-P2 12V-P2 Continuous Power 700 W 1000 W 2000 W 3000 W Input Voltage 12V DC Output Voltage 115V AC Peak surge 1400 W 2000 W 4000 W 6000 W Efficiency > 90% Frequency 60Hz Total harmonic...
  • Page 20 Dimensions 700W 1000W [12.213in] [3.327in] 310.20mm 84.50mm [3.31in] [12.88in] 84.07mm 327.15mm [7.384in] [6.75in] 187.56mm 171.45mm 2000W 3000W [18.854in] 478.90mm [17.75in] [3.996in] [4.00in] 101.50mm 450.85mm 101.60mm [8.56in] 217.42mm...
  • Page 21 RENOGY.COM Renogy reserves the right to change the contents of this manual without notice. 2775 E Philadelphia St, Ontario, CA 91761, USA 909-287-7111 www.renogy.com 苏州高新区科技城培源路1号5号楼-4 400-6636-695 https://www.renogy.cn https://www.renogy.jp https://ca.renogy.com https://au.renogy.com https://uk.renogy.com https://de.renogy.com...
  • Page 22 ROVER SERIES 20A | 30A | 40A Version 1.3...
  • Page 23 Important Safety Instructions Please save these instructions. This manual contains important safety, installation, and operating instructions for the charge controller. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information. Indicates a potentially dangerous condition. Use extreme caution WARNING when performing this task Indicates a critical procedure for safe and proper operation of the...
  • Page 24 Battery Safety Use only sealed lead-acid, flooded, gel or lithium batteries which must be deep cycle. Explosive battery gases may be present while charging. Be certain there is enough ventilation to release the gases. Be careful when working with large lead acid batteries. Wear eye protection and have fresh water available in case there is contact with the battery acid.
  • Page 25 Table of Contents General Information Additional Components Optional Components Identification of Parts Installation Operation LED Indicators Rover Protections System Status Troubleshooting Error Codes Maintenance Fusing Technical Specifications Electrical Parameters General Battery Charging Parameters ROVER: PV Power – Conversion Efficiency Curves Dimensions...
  • Page 26 General Information The Rover Series charge controllers are intelligent controllers suitable for various off-grid solar applications. It protects the battery from being over-charged by the solar modules and over-discharged by the loads. The controller features a smart tracking algorithm that maximizes the energy from the solar PV module(s) and charge the battery.
  • Page 27 Therefore, assuming 100% efficiency: Power In = Power Out Volts In * Amps In = Volts out * Amps out Although MPPT controllers are not 100% efficient, they are very close at about 92-95% efficient. Therefore, when the user has a solar system whose Vmp is greater than the battery bank voltage, then that potential difference is proportional to the current boost.
  • Page 28 Four Charging Stages The Rover MPPT charge controller has a 4-stage battery charging algorithm for a rapid, efficient, and safe battery charging. They include: Bulk Charge, Boost Charge, Float Charge, and Equalization. Battery Voltage Bulk Charge Constant charging Float Charge Equalize Boost Boost...
  • Page 29 The charge controller will reduce the voltage charge to smaller quantity, while lightly charging the battery. The purpose for this is to offset the power consumption while maintaining a full battery storage capacity. In the event that a load drawn from the battery exceeds the charge current, the controller will no longer be able to maintain the battery to a Float set point and the controller will end the float charge stage and refer back to bulk charging.
  • Page 30 The BT-1 Bluetooth module is a great addition to any Renogy charge controllers with a RS232 port and is used to pair charge controllers with the Renogy BT App. After pairing is done you can monitor your system and change parameters directly from you cell phone or tablet. No more wondering how your system is performing, now you can see performance in real time without the need of checking on the controller’s LCD.
  • Page 31 Identification of Parts 11 12 Key Parts 1. PV LED Indicator 2. Battery LED Indicator 3. Load LED Indicator 4. System Error LED Indicator 5. LCD Screen 6. Operating Keys 7. Mounting Holes 8. Remote Temperature Sensor Port (optional accessory) 9.
  • Page 32 Installation Recommended tools to have before installation: Multi-Meter Screwdriver Connect battery terminal wires to the charge controller FIRST then connect the WARNING solar panel(s) to the charge controller. NEVER connect solar panel to charge controller before the battery. Do NOT connect any inverters or battery chargers into the LOAD TERMINAL of WARNING the charge controller.
  • Page 33 Battery...
  • Page 34 Load (optional) Solar Panels...
  • Page 35 Bluetooth Module communication (optional) Temperature Sensor (optional, not polarity sensitive) Place the sensor close to the battery Do NOT place the Temperature Sensor lug inside the battery cell. NOTE Mounting Recommendations WARNING Never install the controller in a sealed enclosure with flooded batteries. Gas can accumulate and there is a risk of explosion.
  • Page 36 2. Check for Clearance—verify that there is sufficient room to run wires, as well as clearance above and below the controller for ventilation. The clearance should be at least 6 inches (150mm). 3. Mark Holes 4. Drill Holes 5. Secure the charge controller. 6 inches (150mm) warm air...
  • Page 37 Using Mounting Hole Step 1. Measure distance between each mounting hole on the Rover. Using that distance drill 4 screws onto desired surface. Step 2. Align the Rovers mounting holes with the screws Step 3. Verify all screw heads are inside the mounting holes.
  • Page 38 Using Mounting Brackets Step 1. Install the brackets using the provided components Step 2. Align the mounting brackets to desired surface and use the appropriate screws to drill into surface (screws not included) Step 3. Verify mounting is secure...
  • Page 39 Operation Rover is very simple to use. Simply connect the batteries, and the controller will automatically determine the battery voltage. The controller comes equipped with an LCD screen and 4 buttons to maneuver though the menus. NOTE:Please set the correct battery type the first time you use. Startup Interface Main Display Main Screen...
  • Page 40  / Page U p/ Increase parameter value Page Down/ Decrease parameter value  / - Return to the previous menu  Enter sub menu/ save parameter value/ ENTER/  turn load on or off in manual mode...
  • Page 41 Programming Battery Type To enter the battery programming settings hover over the Battery Voltage screen and press down the Enter button .When the battery type starts to flash press the Select button to cycle through the battery types and press Enter to finalize selection .When selecting the Lithium setting the user can change battery voltage from 12V to 24V and select the charging voltage.
  • Page 42 “USER” mode. Press and hold the right arrow to enter the programming settings and continue pressing the right arrow button until you see the desired voltage screen. NOTE Battery charging parameters can also be programmed using the Renogy BT APP. Read the corresponding user manuals for more information.
  • Page 43 Programming Load Terminal 1. This screen is displaying the current Load Mode. 2. To enter screen 2 press and hold the Enter button. This screen will allow you to change the load mode. 3. To change the load mode press the up or down button. 4.
  • Page 44 LCD Indicators nighttime daytime solar panel charging battery discharging load parameter value charging stage system voltage setting serial port bluetooth abnormality battery type unit LED Indicators Indicating the controller's current ①---PV array indicator charging mode. ① ②---BAT indicator Indicating the battery's current state. ②...
  • Page 45 PV Indicator (1) Status WhiteSolid The PV system is charging the battery bank White Slow Flashing The Controller is undergoing boost stage White Single Flashing The Controller is undergoing float stage White Fast Flashing The Controller is undergoing equalization stage The oversized PV system is charging the battery White Double Flashing bank at the rated current.
  • Page 46 Rover Protections Protection Behavior When PV shot circuit occurs, the controller will stop charging. PV Array Short Circuit Clear it to resume normal operation. if the PV voltage is larger than maximum input open voltage 100VDC. PV will remain disconnected until the voltage drops PV Overvoltage below 100VDC.
  • Page 47 System Status Troubleshooting PV indicator Troubleshoot Ensure that the PV wires are correctly and tightly secured inside the charge controller PV terminals. Use a multi-meter to make Off during daylight sure the poles are correctly connected to the charge controller. BATT Indicator Troubleshoot Disconnect loads, if any, and let the PV modules charge the battery...
  • Page 48 Maintenance Risk of Electric Shock! Make sure that all power is turned off before touching the WARNING terminals on the charge controller. For best controller performance, it is recommended that these tasks be performed from time to time. 1. Check that controller is mounted in a clean, dry, and ventilated area. 2.
  • Page 49 Technical Specifications Electrical Parameters Model RVR-20 RVR-30 RVR-40 Nominal system voltage 12V/24V Auto Recognition Rated Battery Current Rated Load Current Max. Battery Voltage Max Solar Input Voltage 100 VDC 12V @ 260W 12V @ 400W 12V @ 520W Max. Solar Input Power 24V @ 520W 24V @ 800W 24V @ 1040W...
  • Page 50 2 hours 1-10 Hrs. *Battery charging parameters in USER mode can be programmed using the Renogy BT App. **Default charging parameters in LI mode are programmed for 12.8V LFP battery. Before using Rover to charge other types of lithium battery, set the parameters according to the suggestions from battery manufacturer.
  • Page 51 Rover– Conversion Efficiency Curves Illumination Intensity: 1000W/ m Temp 25℃ 1.12 Volt System Conversion Efficiency MPPT 12V conversion efficiency (12V battery) 20 Vmp 40 Vmp 60 Vmp 75 Vmp 525 500 475 450 425 400 375 350 300 250 200 150 100 50 Output power(W)...
  • Page 52 Dimensions RVR-20 150.40 68.20 R2.60 R4.50 13.87 Product dimensions:210*151*68.2mm Maximum Wire Gauge 8 AWG 117.32 143.63 RVR-30/40 77.30 R2.60 R5.00 Product dimensions:238*172*77.3mm Maximum Wire Gauge 8 AWG 123.46 167.60 Dimensions in millimeters (mm) NOTE...
  • Page 53 RENOGY.COM Renogy reserves the right to change the contents of this manual without notice. 2775 E Philadelphia St, Ontario, CA 91761, USA 909-287-7111 www.renogy.com customerservice@renogy.com 苏州高新区科技城培源路1号5号楼-4 400-6636-695 https://www.renogy.cn sales@renogy.cn https://www.renogy.jp onlinestorejp@renogy.com https://ca.renogy.com onlinestoreca@renogy.com https://au.renogy.com onlinestoreau@renogy.com https://uk.renogy.com onlinestoreuk@renogy.com https://de.renogy.com onlinestorede@renogy.com https://fr.renogy.com...
  • Page 54 ROVER SERIES 20A | 30A | 40A Version 1.0...
  • Page 55 Wichtige Sicherheitshinweise Bitte beachten Sie die folgenden Hinweise. Die folgenden Symbole veranschaulichen die Verwendung des gesamten Handbuchs, um anzuzeigen, dass eine potenziell gefährliche Situation in einer Operation oder eine wichtige sichere Prozedur vorhanden sein kann, die berücksichtigt werden muss. Weist auf einen möglicherweise gefährlichen Betrieb WARNUNG hin, der zu Verletzungen führen kann.
  • Page 56 Sicherheitshinweise der Batterie Verwenden Sie nur Batterie mit hohen Zyklus: versiegelte Blei-Säure-, Flut-, Gel- oder Lithium-Batterien. Zum Zeitpunkt des Ladevorgangs kann das Batterie-Blasgas vorhanden sein, wodurch ausreichend Raum zum Freisetzen des Gases sichergestellt wird. Seien Sie vorsichtig, wenn Sie eine große Kapazität von Blei-Säure-Batterien benutzen.
  • Page 57 Gliederung Informationen Zusatzkomponenten Optionale Zubehöre Identifizierung der Komponenten Installation Betrieb LED-Anzeige Rover-Schutz Systemstatusüberholung Fehlercodes Wartung und Reparatur Sicherung Technische Parameter Elektrische Parameter Allgemein Batterieladeparameter ROVER: Leistungskurve der PV-Leistungsumwandlung Maße...
  • Page 58 Informationen Laderegler Rover -Serie eignen sich für verschiedene netzunabhängige Solaranwendungen. Sie schützt die Batterie vor Überladung des Solarmoduls und die Überlastung durch die Lasten. Die Steuerung verwendet einen intelligenten Verfolgungsalgorithmus, um die vom PV-Modul gewonnene Energie zu maximieren und die Batterie aufzuladen. Zur gleichen Zeit, Niederspannung trennt die Funktion (LVD), um übermäßige Batterieentladung zu verhindern.
  • Page 59 Nehmen wir daher unter 100% Effizienzbedingungen an: Eingangsleistung = Ausgangsleistung Eingangsspannung * Eingangsstrom = Ausgangsspannung * Ausgangsstrom Obwohl der Wirkungsgrad des MPPT-Solarladereglers nicht 100% beträgt, liegt seine Effizienz dennoch bei 92-95%.Wenn die Solarkomponente eine Spitzenleistungspunktspannung (Vmp) hat, die größer als die Batteriespannung ist kann es den Batterieladestrom proportional größer als der Ausgangsstrom des Solarmoduls führen.
  • Page 60 Vierstufige Ladestufe Der Solarregler Rover MPPT verfügt über vier schnelle, effiziente und sichere Batterieladeverfahren. Sie umfassen: schnelles Aufladen, Anhebendes Aufladen,Schwebeladung und ausgeglichenes Aufladen in vier Stufen. Batteriespannung Schnelle Ladung behaltende Ladung Erhaltungsladung Ausgleichserhöhung Boost Ladungsrückkehrspannung Time Ladestrom behaltende zeit:2 St. (Anwendungsbereich:10-180 Min.
  • Page 61 Der Zweck der Erhaltungsladung besteht darin,die Batterie aufgrund der Selbstentladung zu kompensieren und das System durch den Stromverbrauch eine geringere Last zu erzeugen, während die Batteriespeicherkraft voll gehalten wird. Während der Erhaltungsladungsphase kann die Last weiterhin Energie von der Batterie aufnehmen.Wenn die Systemlast den Solarladestrom überschreitet, kann die Steuerung die Batteriespannung nicht mehr im eingestellten Erhaltungsladewert halten.Wenn die Batteriespannung niedriger als die Ladungsrückgewinnungseinstellung ist, verlässt die Steuerung die Erhaltungsladungsphase und kehrt zur Schnellladephase zurück.
  • Page 62 Das BT-1 Bluetooth-Modul ist eine großartige Ergänzung zu allen Renogy-Ladereglern mit RS232-Anschluss und wird zum Koppeln von Ladereglern mit der Renogy BT App verwendet. Nach dem Pairing können Sie Ihr System überwachen und Parameter direkt von Ihrem Handy oder Tablet aus ändern. Sie müssen sich nicht mehr fragen, wie sich Ihr System verhält.
  • Page 63 Identifizierung der Komponenten 11 12 Schlüsselwörter 1. PV LED-Leuchten 2. Batterie-LED Leuchten 3. Last LED Leuchten 4. Systemfehler-LED Leuchten 5. LCD-Anzeige 6. Bedientaste 7. Montagelöcher 8. Ferntemperatursensoranschluss (optional) 9. PV-Klemmen 10. Batterieklemmen 11. Lastanschluss 12. RS-232 Anschluss (optional)
  • Page 64 Installation Installation Empfohlene Werkzeuge: Schraubendreher Multimeter Schließen Sie das Batteriekabel zuerst an den Solarladeregler an und schließen WARNUNG Sie dann das Solarpanel an den Solarladeregler an. Schließen Sie das Solarpanel Schließen Sie keinen Wechselrichter oder Ladegerät an die Lastklemme des WARNUNG Solarladereglers an.
  • Page 65 Batterie...
  • Page 66 Last (optional) Solarmodule...
  • Page 67 Bluetoothe-Modul für Kommunikation (optional) Temperatursensor (optional, nicht polar empfindlich) Bitte legen Sie in der Nähe der Batterie Bitte legen Sie in der Nähe der Batterie HINWEIS Montageempfehlung WARNUNG Installieren Sie das Steuergerät nicht in einem abgedichteten Raum mit einer satten Flüssigkeitsbatterie.Das Gas kann sich ansammeln und es besteht Explosionsgefahr.
  • Page 68 2. Überprüfen Sie den Abstand—bitte bestätigen Sie, ob genügend Platz für die Installation des Kabel vorhanden ist und der Solarregler oben und unten über genügend Lüftungsabstand verfügt. Der Spalt sollten mindestens 150 mm betragen. 3. Markieren Sie das Loch 4. Bohren 5.
  • Page 69 Using Mounting Hole Schritt 1, Bitte messen Sie den Abstand zwischen den einzelnen Montagelöchern am Rover. Mit diesem Abstand bohren Sie 4 Schrauben auf die gewünschte Oberfläche. Schritt 2, Richten Sie die Rovers-Befestigungslöcher an den Schrauben aus. Schritt 3, Bitte checken Sie, ob alle Schraubenköpfe in den Befestigunglöchern gelegt worden ist.
  • Page 70 Halterung benutzen Schritt 1, Installieren Sie die Halterungen mit den mitgelieferten Komponenten Schritt 2, Richten Sie die Montagehalterungen an der gewünschten Oberfläche aus und bohren Sie mit den entsprechenden Schrauben in die Oberfläche. (Schrauben nicht im Lieferumfang enthalten) Schritt 3, Die Überprüfung der Montage ist sicher...
  • Page 71 Betrieb Weil Rover einfach zu verwendet ist, man kann leicht mit der Batterie verbinden. Der Laderegler erkennt automatisch die Batteriespannung. Der Regler verfügt über auch einen LCD-Bildschirm und vier Taste, um die Parameter vom Solarsystem leicht einzustellen. Bitte stellen Sie beim ersten Verwenden den richtigen Batterietyp ein. Startseite Hauptseite Hauptüberwachungsseite...
  • Page 72 Das Menü scrollt nach oben / Unter den  / Einstellung-Modus die Parameter ansteigen Das Menü scrollt nach unten / Unter den  / - Einstellung-Modus die Parameter abnehmen Zurück zum vorherigen Menü  Programmierdichtung Untermenü aufrufen / Parameterwert ENTER/  speichern Schalten Sie die Last im manuellen Modus ein oder aus...
  • Page 73 Programmieren des Batterietyps Wenn die Batteriespannung auf dem Bildschirm angezeigt wird, drücken Sie die Eingabetaste. Wenn der Batterietyp blinkt, drücken Sie die Auswahltaste, um den Batterietyp zu wählen. Bei Auswahl der Lithium-Einstellung kann der Benutzer die Batteriespannung von 12 V auf 24 V ändern und die Ladespannung auswählen.
  • Page 74 Batteriebetrieb "USER" verfügbar. Halten Sie die rechte Pfeiltaste gedrückt, um die Programmiereinstellungen einzugeben, und drücken Sie die rechte Pfeiltaste weiter, bis die gewünschte Spannungsanzeige angezeigt wird. HINWEIS Batterieladeparameter können auch mit der Renogy BT APP programmiert werden. Weitere Informationen finden Sie in den entsprechenden Benutzerhandbüchern...
  • Page 75 Einstellung von Lastmodus 1, Dieser Bildschirm zeigt den aktuellen Lademodus an 2, Um in Bildschirm 2 zu gelangen, halten Sie die Eingabetaste gedrückt, um den Betriebsmodus zu ändern. 3, Um den Lademodus zu ändern, schließen Sie die Auf- oder Ab-Taste an. 4, Nachdem Sie den gewünschten Lademodus ausgewählt haben, drücken Sie die Eingabetaste, um die Einstellungen zu speichern.
  • Page 76 LCD-Anzeige Nachtanzeige Solarpanelanzeige Tagesanzeige Ladeanzeige Batterie Entladung Last Parameter Ladephasen Einstellungen Bluetooth- Batterietyp Einheitsanzeigebereich Anzeige Anweisungen für Systemspannung Abweichung den seriellen Port LED-Anzeige Aktuellen Ladenmodus vom ①---PV-Array Indikator Laderegler ausgeben. ① Aktuelle Situation von Batterie ausgeben. ②---BAT-Indikator ② ③ Die Situation von On/off ausgeben. ③---LAST-Indikator ④...
  • Page 77 PV-Indikator (1) Zustand Weißes Licht Die PV-Indikator lädt den Akku auf eingeschaltet Weißes Licht Solarladeregler steigert Ladungsstufe langsames Blinken Weißer Einzelblitz Solarladeregler in der schwimmenden Stufe Der Solarladeregler befindet sich in der Weißer Schnellblitz Ausgleichsladephase überdimensionierte Solaranlage für Weißes Doppelblitz Aufladen der Batteriebank mit dem Nennstrom.
  • Page 78 Rover Schutz Schutz Verhalten Wenn die PV kurzgeschlossen ist, hört die Steuerung auf zu Photovoltaik-Array- laden. Fehlerbehebung, um den normalen Betrieb wieder Kurzschluss aufzunehmen. wenn die PV-Spannung größer als die maximale PV-Überspannung Eingangs-Öffnungsspannung 100VDC ist. PV bleibt getrennt, bis die Spannung unter 100VDC fällt. Der Solarladeregler begrenzt den Batterieladestrom auf den PV-Überlauf maximalen Nennstrom der Batterie.
  • Page 79 Systemstatusüberholung PV-Anzeige Fehlerbehebung Vergewissern Sie sich, dass die PV-Kabel ordnungsgemäß und am Arbeiten nicht PV-Solarladeregler im Solarladeregler befestigt sind.Verwenden Sie ein Multimeter, um sicherzustellen, dass die positiven und negativen während des Tages Anschlüsse ordnungsgemäß mit dem Solarladeregler verbunden sind. Akkuanzeige Fehlerbehebung Trennen Sie die Last (falls vorhanden) und lassen Sie das PV-Modul den Akku laden.Überprüfen Sie mit dem Multimeter die Änderung der...
  • Page 80 Wartung und Reparatur WARNUNG GEFAHR DES ELEKTRISCHEN SCHLAGS!Vergewissern Sie sich, dass alle WARNUNG Netzteile ausgeschaltet sind, bevor Sie die Anschlüsse an der Ladesteuerung berühren. Um die beste Leistung des Solarladereglers zu erzielen, ist es ratsam, diese Aufgaben von Zeit zu Zeit durchzuführen. 1.
  • Page 81 Technische Parameter Elektronische Parameter Model RVR-20 RVR-30 RVR-40 Nennspannung des Systems 12V/24V Auto-Erkennung Bemessungs-Batteriestrom Nennlaststrom Max. Batteriespannung Max. Solar-Eingangsspannung 100 VDC 12V @ 260W 12V @ 400W 12V @ 520W Max.Solar-Eingangsleistung 24V @ 520W 24V @ 800W 24V @ 1040W ≤100mA @ 12V Eigenverbrauch ≤58mA @ 24V...
  • Page 82 2 hours ----- *1-10 Hrs. *Mit der Renogy BT-App kann die Batterieladeparameter im USER-Modus programmiert werden. **Die voreingestellten Ladeparameter im LI-Modus sind für 12,8 V-LFP-Akkus programmiert. Bevor Sie Rover zum Laden anderer Lithiumbatterietypen verwenden, stellen Sie die Parameter gemäß den Empfehlungen des Batterieherstellers ein.
  • Page 83 Rover PG– Stromerzeugung-Umwandlungskurve Lichtintensität: 1000W/ m Luftfeuchtigkeit:25℃ 1.12 Volt System Conversion Efficiency MPPT 12V conversion efficiency (12V battery) 20 Vmp 40 Vmp 60 Vmp 75 Vmp 525 500 475 450 425 400 375 350 300 250 200 150 100 50 Output power(W)...
  • Page 84 Maße RVR-20 150,40 68,20 R2,60 R4,50 13,87 Maße:210*151*68,2mm Maximale Drahtstärke 8 AWG 117,32 143,63 RVR-30/40 77,30 R2,60 R5,00 Maße:238*172*77,3mm Maximale Drahtstärke 8 AWG 123,46 167,60 Maße im Millimeter (mm) HINWEIS...
  • Page 85 RENOGY.COM Renogy reserves the right to change the contents of this manual without notice. 2775 E Philadelphia St, Ontario, CA 91761, USA 909-287-7111 www.renogy.com customerservice@renogy.com 苏州高新区科技城培源路1号5号楼-4 400-6636-695 https://www.renogy.cn sales@renogy.cn https://www.renogy.jp onlinestorejp@renogy.com https://ca.renogy.com onlinestoreca@renogy.com https://au.renogy.com onlinestoreau@renogy.com https://uk.renogy.com onlinestoreuk@renogy.com https://de.renogy.com onlinestorede@renogy.com https://fr.renogy.com...

This manual is also suitable for:

700w2000w3000w