Download Print this page
HAAS + SOHN HSP 6 Equipment Sheet
HAAS + SOHN HSP 6 Equipment Sheet

HAAS + SOHN HSP 6 Equipment Sheet

Pellet stove with heat exchanger

Advertisement

Quick Links

Equipment sheet
HSP 6 with heat exchanger
HSP 6 with heat exchanger
Equipment sheet
GB
Pellet stove with heat exchanger
0553808501400m

Advertisement

loading
Need help?

Need help?

Do you have a question about the HSP 6 and is the answer not in the manual?

Questions and answers

Summary of Contents for HAAS + SOHN HSP 6

  • Page 1 Equipment sheet HSP 6 with heat exchanger HSP 6 with heat exchanger Equipment sheet Pellet stove with heat exchanger 0553808501400m...
  • Page 2 Introduction We thank you very much for purchasing our product! The description of the heating device will inform you in detail about the design, technical specification and operation of the heating device. We recommend you to acquaint yourselves closely with these data. In this way, you will avoid possible faults during the proper assembly and operation.
  • Page 3 5.3.2. Horizontal cleaning of the conduits of combustion products.......... 14 5.4. Cleaning of the exchanger...................... 18 6. Replacement parts list......................21 6.1. Replacement parts list (without trim parts)................21 6.2. Detail A1............................ 24 6.3. Replacement parts list HSP 6 with heat exchanger............25 7. Circuit diagram .......................... 27...
  • Page 4 Important Information from Manufacturer! IMPORTANT Please, observe the following instructions: Quality of wood pellets: Depending on the manufacturer, there are light, dark, shorter or longer pellets. Even deliveries from one supplier may contain different qualities. Standards for wood pellets are constantly tightened, but: The wood remains wood and has its peculiarities in terms of ash and slag.
  • Page 5 1. Technical data HSP 6 with heat exchanger Heat output range: 3,2 – 10,9kW Nominal heat output: 10 kW Output delivered by the stove body only (NO/PO): 4,1/2,4 kW Output available for heating of water (NO/PO): 6,8/0,8 kW Testing standard:...
  • Page 6 2. Dimensions 2.1. Dimensions...
  • Page 7 2.2. Connection of the exchanger with hydraulic modulus CAUTION The hot-water system is self-ventilating. Item Name Heating water output (outside thread G3/4") Return water intake (outside thread G3/4") Outlet of the safety valve (outside thread G3/4") Filling of the circulation system Venting valve...
  • Page 8 2.3. Connection of the exchanger without hydraulic modulus CAUTION The hot-water system is self-ventilating. Item Name Heating water output (outside thread G3/4") Return water intake (outside thread G3/4") Filling of the circulation system Venting valve...
  • Page 9 3. Pellet Stove Installation and Connection to Chimney The pellet stoves must be connected to a separate chimney. It is not permissible to divert flue gas from other equipment to this chimney. Flue gases are fed through an 80 mm smoke duct connected to the stove smoke- flue being located on the rear side of the stoves.
  • Page 10 Figure 1.1: Chimney outside the building A) Chimney situated outside the building B) Effective chimney height. The chimney must be led above the roof level and fitted with thermal insulation C) External air inlet to the heater D) T-piece with stopper...
  • Page 11 Figure 1.2: Chimney as a part of building A) The smoke-flue inserted into the existing chimney. Here, the possibility of cleaning is required. B) Effective chimney height. C) External air inlet to the heater D) T-piece with stopper...
  • Page 12 Figure 1.3: Connection to the existing chimney A) Existing chimney B) Effective chimney height. C) External air inlet to the heater D) T-piece with stopper E) Smoke-flue...
  • Page 13 4. Cleaning work WARNING Before starting any cleaning work, the stove must be cool down! Once the cleaning work is completed, the correct operating status of the device must be re- established: Put the combustion pot in correctly, close the combustion chamber door. 4.1.
  • Page 14 WARNING If this is not done, the clinker will continue to accumulate. Then the device will no longer be able to ignite properly. Pellets can pile up in the combustion pot. In extreme cases, this can reach all the way back to the pellet chute.
  • Page 15 5. Maintenance work WARNING Before starting any cleaning work, the stove must be cool down! The mains plug must be pulled out of the power supply socket (always in advance)! WARNING Devices that are not maintained in accordance with our specifications must not be operated. Failure to observe this point will invalidate all guarantee claims.
  • Page 16 5.2. Cleaning of the ash pan - once a week WARNING The frequency of maintenance in turn depends to a large extent on the pellet quality (ash content). Quality pellets have a low ash content of about 0.2-0.3%. However, if the ash content is higher (0.5% and over), the interval from maintenance to maintenance is reduced and the accumulation of ash increases by 2 or 3 times.
  • Page 17 5.3. Cleaning of the exchanger - once a week CAUTION We recommend you to clean the conduits of combustion products and the exchanger once in a week. Please perform the short-time cleaning in two steps: 5.3.1. Vertical cleaning of the exchanger •...
  • Page 18 5.3.2. Horizontal cleaning of the conduits of combustion products • Get the cleaning bar from the rear cover of the stove. Next, remove the cover plug and dismount the screw M10x70 by means of an Allen wrench, located behind the ash-pan door. After having finished the cleaning by means of the blade, mount the screw and fit the cover plug to their places again.
  • Page 19 Figure 5a...
  • Page 20 Figure 5b...
  • Page 21 Figure 5c Description Pos. Piece No. PR 1 piece Allen wrench 6mm 9001700060005 1 piece Screw M10x70 0030121000705 Drawbar of cleaning 1 piece 0433317006063...
  • Page 22 5.4. Cleaning of the exchanger CAUTION Check and clean the flue-gas ways, exhaust (flue-gas) fan and flue-gas ducts at the latest after 1000 kg of pellets have been consumed. Clean with a brush or an ash extractor. CAUTION After completion of the cleaning make sure that when putting back the covers, the seals are seated in the right positions.
  • Page 23 Figure 6...
  • Page 24 Figure 7: Removing the side wall...
  • Page 25 6. Replacement parts list 6.1. Replacement parts list (without trim parts)
  • Page 26 Description Pos. Piece No. PR Replacement parts list (without trim parts) Complete combustion chamber door/black 1 piece 0553808005300 Complete combustion chamber door/ 1 piece 0553808015300 anthracite Ash-pan door/anthracite 1 piece 0553808005060 Ash pan/anthracite 1 piece 0553808005600 1 piece Burner 0553808005620 Protection grate 1 piece 0551908006709...
  • Page 27 Screw conveyor motor 1 piece 0089500000006 1 piece Air inlet funnel 0553808015320 1 piece Hose Meniflex AL L=500 0553808005322 Entry to the panel of flanges 1 piece 0553808005901 Room temperature sensor 1 piece 0089500390005 Ignition 1 piece 0541908005202 Outlets of the hydraulic system – cock+Ms 1 piece 0088600000055 Cross+inserts –...
  • Page 28 6.2. Detail A1 Description Pos. Piece No. PR Detail A1 Screwing door — set 1 piece A1.1. 0541908305001 Door hinge/black — set 1 piece A1.2. 0553808006340 Door hinge/anthracite — set 1 piece 0553808005340 A1.2. 1 piece A1.3. Glass holder/black — set 0551908035308 1 piece A1.3.
  • Page 29 6.3. Replacement parts list HSP 6 with heat exchanger Description Pos. Piece No. PR Replacement parts list HSP 6 with heat exchanger Side wall left+right/anthracite 2 piece 56+58 0553808006140 Side wall left+right/white 2 piece 56+58 0553808016140 Front plate/anthracite 1 piece...
  • Page 30 Back wall upper 1 piece 0553808006118 Back wall upper 1 piece 0553808005220 1 piece Back wall lower 0553808006119 Edge cover 225 mm 0089500640005 Spring piece 1 piece 0089500640005...
  • Page 31 7. Circuit diagram...
  • Page 32 * If you use a thermostat for a storage tank, you can apply the following types, or any other potential- free thermostat that has at least one NC/NO switched contact: (not supplied by Haas + Sohn) Afriso 7P1 Watts Industries TC-200-AN When using the thermostat function for the storage tank, the stove is switched on according to the external thermostat requirement via the NC contact.