Advertisement

Quick Links

VIVO-X8D8 / BIO-X8G
DIGITAL PROCESSORS & MATRIXES
EclerPLEX Matrix 8x8 Analogue 8x8 Dante/AES67
EclerPLEX Expansion Interface 8x8 Analogue Audio 8x8 GPIO
USER MANUAL
50-0474-0100
VIVO-X8D8 / BIO-X8G
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIVO-X8D8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ecler VIVO-X8D8

  • Page 1 VIVO-X8D8 / BIO-X8G DIGITAL PROCESSORS & MATRIXES EclerPLEX Matrix 8x8 Analogue 8x8 Dante/AES67 EclerPLEX Expansion Interface 8x8 Analogue Audio 8x8 GPIO USER MANUAL 50-0474-0100 VIVO-X8D8 / BIO-X8G...
  • Page 2: Table Of Contents

    4.2.1 Main Features ..........................9 5. INSTALL & CONNECT ....................... 10 Location, Assembly and Ventilation ................... 10 Mains Connection ........................10 VIVO-X8D8 and BIO-X8G interconnection ..............11 Analogue Input Connections ....................12 Analogue Output Connections ..................... 12 Digital Audio Inputs and Outputs..................13 Ethernet Ports..........................
  • Page 3 BIO-X8G ............................21 7.2.1 Front Panel ..........................21 7.2.2 Rear Panel ........................... 21 8. TECHNICAL DATA ........................22 Technical Specifications ......................22 8.1.1 VIVO-X8D8 ..........................22 8.1.2 BIO-X8G............................24 Mechanical Diagram ........................ 26 8.2.1 VIVO-X8D8 ..........................26 8.2.2 BIO-X8G............................27...
  • Page 4: Precautions

    WARNING: Ecler products have a long lifetime of more than 10 years. This product must never be discarded as unsorted urban waste, but must be taken to the nearest electrical and electronic waste treatment centre.
  • Page 5: Key Safety Directions

    1.2 Key Safety Directions Read the following directions. 11. Only use attachments/accessories specified by the manufacturer. Keep the following directions. 12. Unplug the device during lightning Observe all warnings. storms or when unused for long periods. Follow all instructions. Refer all servicing to qualified personnel. Do not use this device in proximity to Servicing is required when the device water.
  • Page 6: Warranty & Environment

    Recycling materials and using non-contaminant components are also top priorities in our green crusade. Ecler has deeply evaluated and analyzed the environmental impacts of all the processes involved in the production of this product, including packaging, and has...
  • Page 7: Package Contents

    1x EU Mains cord. o 16x Euroblock connectors (blue o 1x Multiplug Mains cord. colour). o 4x Washers. o 1x USB holder. o 4x Rubber feet. o 1x Screw. o 1x USB-C Ecler X-Link certified o First Steps Guide. cable. o Warranty card.
  • Page 8: Description & Features

    4. DESCRIPTION & FEATURES 4.1 VIVO-X8D8 VIVO-X8D8 is an EclerPLEX Host matrix with 8 analogue and 8 Dante/AES67 audio input ports, 8 analogue and 8 Dante/AES67 audio output ports, scalable thanks to two X-link ports. A BIO-X8 (or BIO-X8G) expansion unit can be connected to each X-link port. VIVO- X8D8, performing as a Host unit in an EclerPLEX deployment, can contain multiple projects running simultaneously and serve user control panels to end users.
  • Page 9: Bio-X8G

    2 x X-link expansion VIVO host units. ports. • Connection via X-link to the VIVO host unit (1m Ecler certified X-link cable included). • Expansion features (added to the host VIVO unit ones): o 8 MIC / LINE analogue audio inputs ports (+48V Phantom selectable per port).
  • Page 10: Install & Connect

    5. INSTALL & CONNECT 5.1 Location, Assembly and Ventilation VIVO-X8D8 and BIO-X8G have been specially designed to be placed in 19" rack structure, occupying one unit. It is very important that the device is not enclosed or exposed to extreme temperatures, as it generates heat.
  • Page 11: Vivo-X8D8 And Bio-X8G Interconnection

    BIO-X8G works as an expansion. To connect a BIO-X8G to a VIVO-X8D8 device, use an Ecler certified USB-C to USB-C cable (supplied with each BIO unit) and connect it to the X-LINK connector located on the rear panel of both devices.
  • Page 12: Analogue Input Connections

    5.4 Analogue Input Connections VIVO-X8D8 and BIO-X8G feature 8 balanced analogue signal inputs (IN 1 to 8) on their rear panels, supporting both line and microphone levels. Signal management is handled through the EclerPLEX web interface. Signal input connectors are Euroblock, type 3 position screw terminal block. The wiring Live or direct signal ...
  • Page 13: Digital Audio Inputs And Outputs

    5.6 Digital Audio Inputs and Outputs VIVO-X8D8 supports the reception and transmission of 8 channels of digital audio via Dante/AES67 over an Ethernet network, which is compatible with the Dante/AES67 protocol for digital audio over IP. The routing of digital audio signals via Dante/AES67 through the Ethernet network, along with the configuration of Dante/AES67 network ports (IP addresses, mask, etc.) for the...
  • Page 14: Player And Microsd Card

    5.8 Player and microSD card VIVO-X8D8 integrates a set of stereo audio players (SW embedded) capable of playing audio files from a local storage device (microSD card), suitable for background music or voice messages. It includes playlist management and integration with the device’s calendar events for automation.
  • Page 15: Gpo Ports

    5.10 GPO Ports VIVO-X8D8 and BIO-X8G rear panel feature 8 relay outputs NO / NC (normally open / normally closed). Each output's status can be associated with user presets or events through the EclerPLEX web application, enabling functions such as calendar events or the touch of a key on a user panel.
  • Page 16: Start-Up & Operation

    6. START-UP & OPERATION 6.1 Start Up Connect each device to the AC mains and press the ON/OFF button of the rear panel. VIVO-X8D8 BIO-X8G Each device features a front panel LED indicator that lights up when the unit is operational.
  • Page 17: First Steps And Operation

    Connect the VIVO-X8D8 device to the computer using a CAT5 cable or higher (NET1 or NET2 Ethernet port on the VIVO-X8D8 device). If the VIVO-X8D8 device cannot find a DHCP server, it will be able to an automatic private IP addressing (APIPA) and subnet mask from NET1; the device will select its own IP address in the address range 169.254.1.0 to 169.254.254.255 and will also be...
  • Page 18: Login

    Login There are two profiles that can access the app: Administrator: An administrator has access to all functions of the VIVO-X8D8 device and can configure any matrix parameter, event, peripherals, etc. An administrator creates users and control panels for the EclerPLEX user app.
  • Page 19: Panel Functions

    7. PANEL FUNCTIONS 7.1 VIVO-X8D8 7.1.1 Front Panel <: This button allows moving through Dante LED: Lights up when there is a the display different screens. connection with Dante, according following: Enter: Enter button. >: This button allows moving around...
  • Page 20: Rear Panel

    7.1.2 Rear Panel Power Switch: Unit Power ON X-LINK ports: USB-C to USB-C switch. connection to one BIO-X8G to each port. Mains socket base. GPO (8): GPO ports 1-8. RS-232: Euroblock connector for remote control via TP-NET protocol, GPI (8): GPI ports 1-8. RS-232.
  • Page 21: Bio-X8G

    X-LINK: When this LED lights white, On LED: This LED lights up in green it indicates active connection with the colour if the unit is on. VIVO-X8D8. It will blink during the synchronization process and stay continuously lit once the sync is complete and stable.
  • Page 22: Technical Data

    8. TECHNICAL DATA 8.1 Technical Specifications 8.1.1 VIVO-X8D8 VIVO-X8D8 Digital Engine Processor Quad core 64bits 1,5GHz Audio Converters Sampling rate 48 kHz Resolution 32 bit Latency <4ms Frequency response 10Hz to 20kHz (-0,5 dB) Dynamic range ADC:115dB, DAC: 115dB Analogue Audio Input Ports...
  • Page 23 Connectivity Ethernet 2, RJ-45 connector NET1 & NET2 (no switch capability) Ethernet Base-Tx 10 /100Mb, 1Gb Auto X-Over Serial port RS-232, Euroblock, 3-pin connector Programming and control EclerPLEX (Web application), TPNET (UDP/RS232), UCP contro panels X-LINK 2, X-LINK ports. USB-C connector Remote Control Connections GPIs 8, 0 to 12VDC...
  • Page 24: Bio-X8G

    8.1.2 BIO-X8G BIO-X8G Audio Converters Sampling rate 48 kHz Resolution 32 bit Latency <4ms Frequency response 10Hz to 20kHz (-0,5 dB) Dynamic range ADC:115dB, DAC: 115dB Analogue Audio Input Ports Number of input ports 8, MIC/LINE level Connection type Euroblock, 3-pin, balanced Input sensitivity -32,5 dBV to +18,5 dBV -30,3 dBu to +20,7 dBu...
  • Page 25 Desktop, 19" racks (1RU) Included accessories 1x EU Mains cord, 1x Multiplug Mains cord, 4x Washers, 4x Rubber feet, 1x USB-C Ecler X-Link certified cable, 16x Euroblock connectors (green colour), 16x Euroblock connectors (blue colour), 1x USB holder, 1x Screw.
  • Page 26: Mechanical Diagram

    8.2 Mechanical Diagram 8.2.1 VIVO-X8D8 All measurements are in mm.
  • Page 27: Bio-X8G

    8.2.2 BIO-X8G All measurements are in mm.
  • Page 28 NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications. For technical queries contact your supplier, distributor or complete the contact form on our website, Support / Technical requests. Motors, 166‐168 08038 Barcelona, Spain Tel. (+34) 932238403 information@ecler.com www.ecler.com...

This manual is also suitable for:

Bio-x8g

Table of Contents