Video Projector Functions (Cont.)
Name
getLampTime()
getWarmUpTime()
setCoolDownTime(secs)
setCounterNotificationOn(state)
setLampPower(ON)
setLampPower(OFF)
setLampPower(ps)
setLampTime(hours)
setWarmUpTime(secs)
processCoolDownCounterEvent(int)
processLampPowerEvent(WARMING_UP)
processLampPower-
Event(COOLING_DOWN)
processLampPowerEvent(ON)
processLampTimeEvent(int)
processWarmUpCounterEvent(int)
moveMenuCursor(UP)
moveMenuCursor(DOWN)
moveMenuCursor(LEFT)
moveMenuCursor(RIGHT)
moveMenuCursor(UP_LEFT)
moveMenuCursor(UP_RIGHT)
314
Component
Channel Level Command
ILampComponent
ILampComponent
ILampComponent
ILampComponent
ILampComponent
27
ILampComponent
28
ILampComponent
255
ILampComponent
ILampComponent
ILampComponentListener
ILampComponentListener
253
ILampComponentListener
254
ILampComponentListener
255
ILampComponentListener
ILampComponentListener
IMenuComponent
45
IMenuComponent
46
IMenuComponent
47
IMenuComponent
48
IMenuComponent
51
IMenuComponent
52
Constant
?LAMPTIME
?WARMUP
COOLDOWN-<time>
COUNTERNOTIFY-
<state>
PWR_ON
PWR_OFF
POWER_ON
LAMPTIME-<time>
WARMUP-<time>
COOLING-<time>
LAMP_WARMING_FB
LAMP_COOLING_FB
LAMP_POWER_FB
LAMPTIME-<time>
WARMING-<time>
MENU_UP
MENU_DN
MENU_LT
MENU_RT
MENU_UP_LT
MENU_UP_RT
Notes
Query for lamp time, responds with LAMP-
TIME-<time> where <time> is in hours
Query for warm up time, responds with
WARMUP-<time> where <time> is in sec-
onds
Set cool down time where <time> is in sec-
onds
Turn counter notification on or off, where
<state> is 1 or 0
Momentary Function Channel: Lamp power
is turned on when channel is activated
Momentary Function Channel: Lamp power
is turned off when channel is activated
Discrete Function Channel: Lamp power is
on while channel is active
Set lamp time where <time> is in hours
Set warm up time where <time> is in sec-
onds
Cool down counter time, <time> is seconds
remaining
Feedback Channel: Indicates Lamp is
warming and cannot accept commands
Feedback Channel: Indicates Lamp is cool-
ing and cannot accept commands
Feedback Channel: Indicates lamp is ON
Lamp time, <time> is elapsed hours
Warm up counter time, <time> is seconds
remaining
Momentary Function Channel: Move menu
cursor UP
Momentary Function Channel: Move menu
cursor DOWN
Momentary Function Channel: Move menu
cursor LEFT
Momentary Function Channel: Move menu
cursor RIGHT
Momentary Function Channel: Move menu
cursor UP_LEFT
Momentary Function Channel: Move menu
cursor UP_RIGHT
Standard NetLinx API (SNAPI) R 1.8.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cafe duet

Table of Contents