AMX CAFE DUET STANDARD NETLINX API (SNAPI) DEVICES Instruction Manual page 186

Standard netlinx api (snapi) r 1.8.0 devices
Table of Contents

Advertisement

Pool Spa Functions (Cont.)
Name
processPassbackEvent(byte[])
cyclePoolHeatState()
cycleSpaHeatState()
cycleSpaJets()
decrementPoolSetpoint()
decrementSpaSetpoint()
getPoolSpaTemperatureScale()
incrementPoolSetpoint()
incrementSpaSetpoint()
isPoolSpaAuxOn(aux)
setPoolHeatState(OFF)
setPoolHeatState(HEATER)
setPoolHeatState(SOLAR)
setPoolHeatState(SOLAR_PREFERRED)
setPoolLightOn(state)
setPoolPumpOn(state)
setPoolSetpoint(nTemperature)
182
Component
Channel Level Command
IModuleComponentListener
IPoolSpaComponent
123
IPoolSpaComponent
124
IPoolSpaComponent
125
IPoolSpaComponent
153
IPoolSpaComponent
155
IPoolSpaComponent
IPoolSpaComponent
152
IPoolSpaComponent
154
IPoolSpaComponent
IPoolSpaComponent
174
IPoolSpaComponent
175
IPoolSpaComponent
176
IPoolSpaComponent
177
IPoolSpaComponent
172
IPoolSpaComponent
170
IPoolSpaComponent
Constant
POOL_HEAT
SPA_HEAT
SPA_JETS
POOL_HEAT_DN
SPA_HEAT_DN
?POOLSCALE
POOL_HEAT_UP
SPA_HEAT_UP
?POOLAUX-<aux num-
ber>
POOL_HEAT_OFF
POOL_HEATER
POOL_SOLAR
POOL_SOLAR_PREF
POOL_LIGHT_ON
POOL_PUMP_ON
39
POOL_HEAT_LVL
Notes
When passback is on, each string received
form the device is sent to the NetLinx pro-
gram as a string. Use a DATA_EVENT
event with a STRING handler to caputre
the data from the device.
Momentary Function Channel: Cycle Pool
heat state when channel is activated
Momentary Function Channel: Cycle Spa
heat state when channel is activated
Momentary Function Channel: Cycle Spa
jets when channel is activated
Momentary Function Channel: Pool set-
point is decremented when channel is acti-
vated
Momentary Function Channel: Spa set-
point is decremented when channel is acti-
vated
Query for the Pool/Spa temperature scale,
responds with POOLSCALE-<scale>
where <scale> is FAHRENHEIT, CELSIUS
Momentary Function Channel: Pool set-
point is incremented when channel is acti-
vated
Momentary Function Channel: Spa set-
point is incremented when channel is acti-
vated
Query for Pool/Spa Aux state, responds
with POOLAUX-<aux number>,<state>
where <state> is 0 (false) or 1 (true)
Momentary Function Channel: Set Pool
heat state to off
Momentary Function Channel: Set Pool
heat state to heater
Momentary Function Channel: Set Pool
heat state to solar
Momentary Function Channel: Set Pool
heat state to solar preferred
Discrete Function Channel: Pool light is on
while channel is active
Discrete Function Channel: Pool pump is
on while channel is active
Set Pool setpoint, value is in degrees C or
F depending on temperature scale