HVAC Functions (Cont.)
Name
getTemperatureScale()
incrementCoolSetpoint()
incrementDehumidifySetpoint()
incrementHeatSetpoint()
incrementHumidifySetpoint()
removeHVACComponent(hvacAddress)
removeHVACComponent(index)
setCoolSetpoint(setpoint)
setDehumidifySetpoint(setpoint)
setFanState(ON)
setFanState(AUTO)
setHeatSetpoint(setpoint)
setHoldOn(state)
setHumidifySetpoint(setpoint)
setHumidifyState(AUTO)
setHumidifyState(DEHUMIDIFY)
setHumidifyState(HUMIDIFY)
setHumidifyState(OFF)
132
Component
Channel Level Command
IHVACComponent
IHVACComponent
140
IHVACComponent
150
IHVACComponent
143
IHVACComponent
148
IHVACComponent
IHVACComponent
IHVACComponent
IHVACComponent
IHVACComponent
214
IHVACComponent
215
IHVACComponent
IHVACComponent
211
IHVACComponent
IHVACComponent
228
IHVACComponent
229
IHVACComponent
230
IHVACComponent
231
Constant
?HVACSCALE
HVAC_COOL_UP
HVAC_DEHUMIDIFY_UP
HVAC_HEAT_UP
HVAC_HUMIDIFY_UP
HVACREMOVEADDR-
<hvacAddress>
HVACREMOVEIDX-
<index>
31
HVAC_COOL_LVL
38
HVAC_DEHUMIDIFY_LVL
HVAC_FAN_ON
HVAC_FAN_AUTO
32
HVAC_HEAT_LVL
HVAC_HOLD_ON
37
HVAC_HUMIDIFY_LVL
HVAC_HUMIDIFY_AUTO
HVAC_DEHUMIDIFY
HVAC_HUMIDIFY
HVAC_HUMIDIFY_OFF
Notes
Query for the temperature scale, responds
with HVACSCALE-<scale> where <scale>
is FAHRENHEIT,CELSIUS
Momentary Function Channel: Increment
the cool setpoint when channel is activated
Momentary Function Channel: Increment
the dehumidify setpoint when channel is
activated
Momentary Function Channel: Increment
the heat setpoint when channel is activated
Momentary Function Channel: Increment
the humidify setpoint when channel is acti-
vated
Remove the thermostat with address
<hvacAddress>, where <hvacAddress> is
a thermostat address
Remove the thermostat at index <index>,
where <index> is 1-x and x is the maximum
supported thermostat index (see specific
module documentation)
Set the cool setpoint, value is in degrees C
or F depending on temperature scale
Set the dehumidify setpoint, value is in per-
cent
Momentary Function Channel: Fan state is
on while channel is active
Momentary Function Channel: Fan state is
auto while channel is active
Set the heat setpoint, value is in degrees C
or F depending on temperature scale
Discrete Function Channel: Thermostat
hold mode is on while channel is active
Set the humidify setpoint, value is in per-
cent
Momentary Function Channel: Humidity
state is auto while channel is active
Momentary Function Channel: Humidity
state is dehumidify while channel is active
Momentary Function Channel: Humidity
state is humidify while channel is active
Momentary Function Channel: Humidity
state is off while channel is active