Refer to cover page for the specifications of your compressor. Use only a fuse or circuit breaker that is the same rating
as the branch circuit the air compressor is operated on. If the compressor is connected to a circuit protected by fuses,
use dual element time delay fuses, as noted in specification chart.
CFM:
CFM:
CFM:
CFM:
CFM: Cubic feet per minute.
SCFM:
SCFM:
SCFM:
SCFM:
SCFM: Standard cubic feet per minute; a unit of
measure of air delivery.
PSIG:
PSIG:
PSIG: Pounds per square inch gauge; a unit of measure
PSIG:
PSIG:
of pressure.
ASME:
ASME:
ASME: American Society of Mechanical Engineers;
ASME:
ASME:
made, tested, inspected and registered to meet the
standards of the ASME.
California Code
California Code
California Code:
California Code
California Code
Code 462 (l) (2)/(M) (2). Specification/Model Label is on
the side of the tank on units that comply with California
Code.
All DeVilbiss Air Power manufactured air compressors
should be operated on not more than a 50% duty cycle.
This means an air compressor that pumps more than
50% of one hour, is considered misuse, because the air
MGP-SL10120H-2A

SPECIFICATIONS

Improper electrical installation of this product
may void its warranty and your fire insurance.
Have circuit wiring performed by qualified per-
sonnel such as a licensed electrician who is
familiar with the current national electric code
and any prevailing local electrical codes.
Unit may comply with California

DUTY CYCLE

GLOSSARY

Cut-In Pressure:
Cut-In Pressure:
Cut-In Pressure: While the motor is off, air tank
Cut-In Pressure:
Cut-In Pressure:
pressure drops as you continue to use your accessory.
When the tank pressure drops to a certain low level the
motor will restart automatically. The low pressure at
which the motor automatically re-starts is called "cut-
in pressure."
Cut-Out Pressure:
Cut-Out Pressure:
Cut-Out Pressure: When you turn on your air com-
Cut-Out Pressure:
Cut-Out Pressure:
pressor and it begins to run, air pressure in the air tank
begins to build. It builds to a certain high pressure
before the motor automatically shuts off - protecting
your air tank from pressure higher than its capacity. The
high pressure at which the motor shuts off is called "cut-
out pressure."
To Lock Out Power:
To Lock Out Power:
To Lock Out Power: Place a lock on the line power
To Lock Out Power:
To Lock Out Power:
switch so no one else can turn on the power.
compressor is undersized for the required air demand.
Maximum compressor pumping time per hour is 30
minutes.
6—ENG