Rohde & Schwarz R&S NPA701 User Manual

Rohde & Schwarz R&S NPA701 User Manual

Power analyzers
Table of Contents

Advertisement

Quick Links

®
R&S
NPA
Power Analyzers
User Manual
(;Ý@Î2)
1179166402
Version 03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R&S NPA701 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Safety and Regulatory Information
Safety Instructions
Provides comprehensive safety guidelines for using the product, including intended use, target audience, lifting, carrying, and operating site requirements.
Labels on the R&S NPA Power Analyzers
Details the various labels found on the R&S NPA power analyzers, covering personal safety, product safety, and identification.
Warning Messages in the Documentation
Explains the meaning of warning messages (DANGER, WARNING, CAUTION, NOTICE) used in the documentation to indicate risks.
Where to Find Key Documents on Rohde & Schwarz
Provides information on how to access important documents, such as certificates and quality management information, on the Rohde & Schwarz website.
Korea Certification Class A
Information regarding Korea certification class A for the R&S NPA power analyzers.
Welcome
Key Features
Highlights the main features and capabilities of the R&S NPA power analyzers.
Documentation Overview
Provides an overview of the R&S NPA user documentation, including links to manuals and other resources.
Getting Started
Preparing for Use
Basic information on setting up the product for the first time, including unpacking and choosing an operating site.
Considerations for Test Setup
Discusses cable selection and electromagnetic interference (EMI) for optimal test setup.
Preparing for Mains Voltage
Guides on preparing the R&S NPA for 115 V or 230 V mains voltage, including fuse types.
Connecting to Power
Instructions on how to safely connect the instrument to the AC power supply and ground the chassis.
Connecting to LAN
Details on establishing Ethernet (LAN) connectivity for remote control and data transfer.
Connecting USB Devices
Information on connecting USB storage devices for data transfer and firmware updates.
Connecting a Device Under Test (DUT)
Instructions on connecting the device under test (DUT) using the R&S NPA-Zx test adapter.
Switching On or Off
Procedure for safely switching the R&S NPA on and off, and disconnecting from power.
Configuring the Initial Instrument Settings
Guide to setting initial instrument configurations, such as the internal clock date and time.
Instrument Tour
Provides an overview of the front and rear control elements and connectors of the R&S NPA.
Trying Out the Instrument
Step-by-step examples for performing typical power measurements and tests with the instrument.
Instrument Control
Details on operating the R&S NPA, including manual interaction and remote control possibilities.
Measurement Setups
Voltage-based Measurement
Instructions for setting up voltage-based measurements, used for high currents.
Current-based Measurement
Instructions for setting up current-based measurements, used for low currents and high voltages.
Connecting a DUT Directly
Guidance on directly connecting a device under test (DUT) within specified voltage and current limits.
Connecting an External AC/DC Shunt or Clamp-on Current Probe
Details on connecting external AC/DC current probes or shunts for current and voltage measurements.
Measurement Parameters and Ranges
Measurement Parameters
Lists all measurable and calculated parameters available for display on the R&S NPA.
Measurement Ranges
Explains how to select voltage and current measurement ranges, including automatic and manual options.
Data Acquisition
Data Acquisition Settings
Configuration options for data acquisition, including voltage, current, mode, peak hold, and refresh settings.
Voltage Settings
Detailed settings for voltage acquisition, including autorange, range, crest factor, and invert functions.
Current Settings
Detailed settings for current acquisition, including autorange, range, crest factor, and invert functions.
Acquisition Mode Settings
Configuration of acquisition modes (DC, AC, AUTO, EXT) and frequency synchronization filters.
Peak Hold Settings
Configuration and usage of the peak hold function to display maximum peak values.
Refresh Settings
Configuration of the display update rate (fast or slow) for measured values.
Measurement Modes
Integrator
Describes the integrator function for measuring energy consumption and related parameters.
Data Logging
Functionality for recording measurement data to internal memory or USB drive, including file formats and storage.
Limit
Configuration of limit values for up to six parameters to define pass/fail criteria.
Standards
Details on performing standardized measurements according to IEC and EN standards for power consumption analysis.
Measuring Power Consumption with the R&S NPA701
Example of configuring and performing standardized power measurements for standby power analysis.
Display Modes
Numeric View
Displays measurement results numerically, with customizable parameter views.
Harmonics View
Displays harmonics magnitude and phase angle as bar graphs or in a table using FFT analysis.
Waveform View
Displays voltage, current, and power traces simultaneously with automatic time axis scaling.
Trendchart View
Displays traces of two selected parameters over time with adjustable time scaling.
Inrush View
Captures high-samplerate records for inrush currents, triggered manually or by events.
Evaluating Inrush Data
Guidance on analyzing inrush measurement results using spreadsheet applications.
External Measurement Modes
Analog Input and Output Settings
Configuration for analog input signal measurement and analog output signal for external evaluation.
Digital Input and Output Settings
Configuration for digital input signal measurement and digital output signal for status information.
Sensor Settings
Configuration for measurements using external probes like shunts or current clamps.
Measuring with an External Probe or Shunt
Instructions on selecting optimal ranges and configuring measurements with external probes.
File and Data Management
Save/Recall Instrument States
Functions to save instrument configurations and settings for later reuse.
Screenshot
Captures and saves the current screen image in graphic file formats.
General Instrument Settings
Update (firmware)
Provides information on updating the instrument firmware via USB.
Interface
Settings related to instrument interfaces for remote control connections.
Miscellaneous
Basic instrument settings including date/time, display, sound, and device name configuration.
Power up
Configuration of the instrument's startup behavior after power loss.
Default
Resets miscellaneous settings to factory defaults, excluding date/time and device name.
Network Operation and Remote Control
Remote Control Interfaces and Protocols
Details on supported interfaces (USB, LAN, GPIB) and protocols for remote instrument control.
Remote Access Settings
Configuration settings for remote access, including USB, Ethernet, and GPIB interface parameters.
Connecting the R&S NPA for Remote Access
Guidance on establishing remote connections via LAN, USB, and IEC 625/IEEE 488 interfaces.
Adjusting the Interface Addresses
Instructions on configuring Ethernet settings, including IP addresses, subnet masks, and gateways.
Starting and Stopping Remote Control
Procedures for initiating, locking, and returning from remote control sessions.
Remote Control Commands
Conventions Used in SCPI Command Descriptions
Explains the conventions and syntax used for SCPI remote control commands.
Common Commands
Lists and describes common SCPI commands used for instrument control and status reporting.
CHANnel:ACQuisition Subsystem
Commands for configuring data acquisition parameters like mode, filters, and ranges.
CHANnel:EXTernal Subsystem
Commands for configuring external interfaces, including analog and digital I/O and sensor settings.
CHANnel:LIMit Subsystem
Commands for configuring limit values for measurement parameters, setting min/max values and activating limits.
CHANnel:MEASurement Subsystem
Commands for configuring measurement parameters, data formats, and function lists.
CHANnel:NAME Subsystem
Commands for defining or querying the instrument's channel name.
DATA Subsystem
Commands for managing logging data, including file names, storage locations, and deletion.
DISPlay Subsystem
Commands for controlling the screen display, such as blacklight activation and text messages.
HardCOPy Subsystem
Commands for configuring hardcopies, including selecting data format and size for screenshots.
INTegrator Subsystem
Commands for setting up the integrator mode, including manual, span, duration, and external trigger.
LOG Subsystem
Commands for setting data logging parameters, including mode, interval, and file name.
STATus Subsystem
Commands for controlling the status reporting system, including operation and questionable status registers.
SYSTem Subsystem
Commands for general instrument functions, such as beeper settings, date/time, and interface selection.
VIEW Subsystem
Commands for configuring display modes like numeric, harmonics, waveform, trendchart, and inrush views.
Troubleshooting and Notifications
Displaying Status Information and Notifications
Explains how the R&S NPA displays notifications, distinguishing between status, information, and error messages.
Problems During Firmware Update
Provides solutions for potential problems that may occur during firmware updates, such as interruptions.
Problems with Remote Control over LAN
Troubleshooting steps for establishing and maintaining LAN connections for remote control.
Contacting Customer Support
Information on how to contact Rohde & Schwarz customer support for technical assistance.
Transporting
Packing
Instructions on using original or similar packaging materials for safe product transport.
Securing
Guidelines for properly securing the product when moving it in vehicles or using transporting equipment.
Transport Altitude
Information on the maximum transport altitude without pressure compensation.
Maintenance, Storage and Disposal
Cleaning
Instructions on how to clean the product safely, avoiding liquids and harsh cleaning agents.
Changing Fuses
Procedure for changing fuses if the R&S NPA does not start.
Storage
Recommendations for storing the product to protect it from dust and ensure proper environmental conditions.
Disposal
Guidelines for the eco-friendly disposal of electrical and electronic equipment.

Table of Contents