TROUBLESHOOTING

Before calling for repair, please review the list below, since the problem may not be a unit malfunction.
SYMPTOM
The Remote Control does not
work.
Odours and smoke are not
removed.
The CLEAN-SIGN Light lights
green even when the air is
impure.
The CLEAN-SIGN Light lights
orange or red even when the air
is clean.
The Plasmacluster Indicator
Light remains green (or blue)
and does not change.
A clicking or ticking sound is
heard from the unit.
The discharged air has an
aroma or odour.
The unit does not operate when
cigarette smoke is in the air.
The Active Carbon Filter Indicator
Light or MIST Unit Indicator Light
remains activated even after re-
placing filter.
The Plasmacluster Indicator
Light or the CLEAN-SIGN Light
will not activate.
Plasmacluster Indicator Light
(mixture of blue and green)
repeats the light/dark colour
cycles.
Mist Unit Indicator Light does not
turn on even water is in.
When the water of the tank does
not decrease or the decrease of
the water is slow.
REMEDY (not a malfunction)
• Have the batteries been depleted?
• Are the batteries inserted correctly?
• Is a fluorescent lighting in the room flickering due to service
life?
• Clean or replace the filters if they appear to be heavily soiled.
(Refer to E-19,E-20)
• The air could be impure at the time the unit was plugged in.
(Refer to E-14)
• The sensitivity of the sensors become unstable when the
opening of the odour sensor or dust sensor is dirty or is clogged.
Clean the dust around the sensor opening using a vacuum
cleaner. (Refer to E-14)
• When in Clean Mode ( or Ion Control Mode), the Plasmacluster
Indicator Light colour will not change.
• Clicking sound is emitted when the unit is in the Ion Control
Mode, and ticking sound is emitted when the unit is generating
ions.
If the sound is irritating, set the unit away from you.
• Check to see if the filters are heavily soiled.
Replace the filters.
• Plasmacluster Air Purifiers emit small traces of ozone which
may produce an odour. These ozone emissions are well below
safety levels set by FDA.
• Is the unit installed in a location that is difficult for the sensor to
detect cigarette smoke?
• Are the dust or odour sensor openings blocked or clogged?
(In this case, clean the openings.) (Refer to E-20)
• After replacing filters, connect the power cord to an outlet and
press associated Reset Button. (Refer to E-18,19)
Care Cycle : Active Carbon Filter : 2 months
MIST Filter : 1 month
• Check to see if the Lights OFF Mode on the Remote Control is
selected. If so, then press the Lights ON/OFF Button on the
Remote Control to activate the indicator lights.
(Refer to E-14)
• The SENTINEL operation is working.
SENTINEL Operation mode is turned on when pressing the
ION AUTO or CLEAN button on the Remote Control.
• Please check if the impurities adhered to the surface of the Float.
Clean the Mist Tray.
Check to see check if the Main Unit is put on a inclined surface.
• Check to see if the Mist unit and Tank are installed correctly.
• Check the Mist Filter. Replace the filter when it is heavily soiled.
(Refer to E-18,21)