Global System Trbl. Reporting Opt. (Addr 1082-1116)45 Area System Trbl. Reporting Opt. (Addr 1120-1137) - Gemini GEM-P3200 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEM-P3200:
Table of Contents

Advertisement

!
Page 46
AREA SYSTEM TR OUBLE REPOR TING OPTIONS (A DDRESS 1120-1157)
SYSTEM RESPONSE
ACTIVATED BY AREA 1
EVENT/TROUBLE
Pulsed Burg. Output
Burglary Output
Fire Output
Reset Relay
Auxiliary Relay
Report Alarm Telco 1
Report Alarm Telco 3
SYSTEM RESPONSE
ACTIVATED BY AREA 2
EVENT/TROUBLE
Pulsed Burg. Output
Burglary Output
Fire Output
Reset Relay
Auxiliary Relay
Report Alarm Telco 1
Report Alarm Telco 3
!
1. Select the desired option by circling " the data values for
each digit
(left and right).
X
GEM-P3200 Programming Instructions
AREA 1 SYSTEM EVENT/TROUBLE
"
LEFT DATA VALUES (CIRCLE
FAIL TO
FAIL TO
KEYPAD
RSRVD.
CLOSE
OPEN
TAMPER
8
4
2
8
4
2
8
4
2
8
4
2
8
4
2
8
4
2
8
4
2
[Defaults as circled from address 1120-1127]
AREA 2 SYSTEM EVENT/TROUBLE
"
LEFT DATA VALUES (CIRCLE
FAIL TO
FAIL TO
KEYPAD
RSRVD.
CLOSE
OPEN
TAMPER
8
4
2
8
4
2
8
4
2
8
4
2
8
4
2
8
4
2
8
4
2
[Default = blank (•) blank (•) from address 1130-1137]
ADDRESS
1120-1127
)
LEFT
ADDR
RIGHT
1
1120
1
1121
1
1122
1
1123
1
1124
1
1125
1
1127
ADDRESS
1130-1137
)
LEFT
ADDR
RIGHT
1
1130
1
1131
1
1132
1
1133
1
1134
1
1135
1
1137
!
2. Add the data values (ex: 15=1+2+4+8) from the selected
options.
WI818D 08/00
AREA 1 SYSTEM EVENT/TROUBLE
RIGHT DATA VALUES (CIRCLE
KEYPAD
KEYPAD
KEYPAD
AMBUSH
AUX.
FIRE
PANIC
2
8
4
2
8
4
2
8
4
2
8
4
2
8
4
8
4
2
8
2
4
AREA 2 SYSTEM EVENT/TROUBLE
RIGHT DATA VALUES (CIRCLE
KEYPAD
KEYPAD
KEYPAD
AMBUSH
AUX.
FIRE
PANIC
2
8
4
2
8
4
2
8
4
2
8
4
2
8
4
8
4
2
8
2
4
L
NAPCO Security Systems
"
)
1
1
1
1
1
1
1
"
)
1
1
1
1
1
1
1

Advertisement