Download Print this page

Removing A Management Module; Installing A Management Module - HP 4400 Replacement Instructions

Controller enclosure management module
Hide thumbs Also See for 4400:

Advertisement

Green—Normal operation
Amber—Fault condition (except during start up, when some cyc-
ling of the LED occurs)
Off—No active remote management
Ethernet LEDs—Solid green indicates a link. Flashing yellow indic-
ates activity.

Removing a management module

1.
Unplug the Ethernet cable from the module.
2.
Lift the latch up on the module (1,
slightly.
3.
Position one hand under the module, and with the other hand, pull
the module out of the controller enclosure (2,
Figure 2 Removing a management module
.

Installing a management module

1.
Insert the management module into the slot in the controller
enclosure.
2.
Push the module forward until a click is detected when fully seated.
3.
Plug the Ethernet cable into the module.
Verifying proper operation
After replacing the management module, check the following to verify
the component is operating properly:
NOTE:
Wait approximately five minutes for the system to check the
component status.
Verify the green LED is lit. If not, try reseating the management
module.
From HP P6000 Command View, navigate to the component as de-
scribed in the
Verifying component failure
status. It should be
(Good).
Figure
2) and pull the module out
Figure
2).
section, and check the
NOTE:
You cannot store modifications to the management module
settings if the array is not initialized.
Page 2

Advertisement

loading

This manual is also suitable for:

P6000