Asus PIKE 1078 User Manual page 40

Lsisas1078 sas raid card
Table of Contents

Advertisement

◊ Wrthru for BAD BBU: Select WBack for Write Policy and unselect this
item if you want the controller to use Writeback mode but the controller
has no BBU or the BBU is bad. If you choose this option, the controller
firmware automatically switches to Writethrough mode if it detects a bad
or missing BBU.
IO Policy: The IO Policy applies to reads on a specific virtual disk. It
does not affect the read ahead cache.
◊ Direct: In Direct I/O mode, reads are not buffered in cache memory.
Data is transferred to the cache and the host concurrently. If the same
data block is read again, it comes from cache memory. This is the
default.
◊ Cached: In Cached I/O mode, all reads are buffered in cache memory.
Disk Cache Policy: Specify the disk cache policy:
◊ Enable: Enable the disk cache.
◊ Disable: Disable the disk cache. This is the default.
◊ NoChange: Leave the current disk cache policy unchanged.
Disable BGI: Specify the background initialization status:
◊ No: Leave background initialization enabled. This means that a
new configuration can be initialized in the background while you use
WebBIOS to do other configuration tasks. This is the default.
◊ Yes: Select Yes if you do not want to allow background initializations
for configurations on this controller.
Select Size: Specify the size of the virtual disk in megabytes. Normally,
this would be the full size for RAID 50 shown in the Configuration Panel
on the right. You may specify a smaller size if you want to create other
virtual disks on the same disk group.
Click Accept to accept the changes to the virtual disk definition, or click Back
9.
to return to the previous settings.
10. Click Next when you are finished
defining virtual disks. The
configuration preview screen
appears, as shown in the right
figure.
11. Check the information in the
configuration preview.
12. If the virtual disk configuration is
acceptable, click Accept to save
the configuration. Otherwise, click
Cancel to end the operation and return to the WebBIOS main menu, or click
Back to return to the previous screens and change the configuration.
2-26
Chapter 2: RAID configuration

Advertisement

Table of Contents
loading

Table of Contents