Cutout Dimensions
IMPORTANT: Be careful to use the correct cutout diagram (on the facing page) to determine the countertop dimensions
for the installation type. Carefully double check all dimensions against the table below and the correct diagram before cut-
ting the countertop.
Installation Type
Diagram
SGM304 without
Figure 1
raised vent
(Square)
SGM304 with
Figure 1
ERV30/PRV30
(Square)
SGM304 with
Figure 1
RV30
(Square)
SGM365 without
Figure 1
raised vent
(Square)
SGM365 with
Figure 1
ERV36/PRV36
(Square)
SGM365 with
Figure 1
RV36
(Square)
SGM466 without
Figure 1
raised vent
(Square)
SGM466 with
Figure 2
PRV46
(Notched)
SGM466 with
Figure 2
RV46
(Notched)
* Total cutout depth, accommodates both the cooktop and raised vent
** IMPORTANT: Notch depth is included in total cutout depth (D). DO NOT add notch depth to total cutout depth (D).
3/8" min. (1.0 cm)
flat countertop overhang
required behind cutout
Stiffener
3/8" min. (1.0 cm) space
behind raised vent
chassis to clear stiffener
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
Side View - SGM Series Cooktop with
ERV or PRV Series Raised Vent
6
Installation Specifications
All tolerances +1/16" (+1.6 mm), -0, unless otherwise noted.
Countertop Dimensions
Cutout
C
(Minimum)
2 7/8"
(7.3 cm)
3/8"
(1.0 cm)
5/8"
(1.6 cm)
2 3/8"
(6.0 cm)
3/8"
(1.0 cm)
5/8"
(1.6 cm)
2 7/8"
(7.3 cm)
3/8"
(1.0 cm)
5/8"
(1.6 cm)
Countertop
SGM series cooktop
Cabinet face
Floor
D
E
19 3/4"
27 3/4"
(50.2 cm)
(68.6 cm)
22 1/2"
27 3/4"
(57.2 cm)*
(68.6 cm)
22 1/4"
27 3/4"
56.5 cm)*
(68.6 cm)
19 3/4"
33 5/8"
(50.2 cm)
(85.4 cm)
22 1/2"
33 5/8"
(57.2 cm)*
(85.4 cm)
22 1/4"
33 5/8"
(56.5 cm)*
(85.4 cm)
19 3/4"
44 3/4"
(50.2 cm)
(113.7 cm)
22 1/2"
44 3/4"
(57.2 cm)*
(113.7 cm)
22 1/4"
44 3/4"
(56.5 cm)*
(113.7 cm)
Stiffener
Side View - SGM Series Cooktop with
F
G
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
43 1/2"
5/8"
(110.5 cm)
(1.6 cm)
43 1/2"
5/8"
(110.5 cm)
(1.6 cm)
5/8" min. (1.6 cm)
flat countertop overhang
required behind cutout
SGM series cooktop
Cabinet face
5/8" min. (1.6 cm) space
behind raised vent
chassis to clear stiffener
RV series raised vent:
Check raised vent
dimensions/specifications
to determine proper fit
4 5/8" (11.7 cm)
9 7/8" (25.1 cm) with
CABP3 blower installed
Floor
RV Series Raised Vent
H
NA
NA
NA
NA
NA
NA
NA
2 5/8" **
(6.7 cm)
2 3/8" **
(6.0 cm)
Countertop