Connecting The Rear Panel Input/Output Terminal Connections - JVC SR-9090U - High Resolution 960 Hour Density Instructions Manual

Sr-9090u timelapse recorder instruction manual (1137kb)
Hide thumbs Also See for SR-9090U - High Resolution 960 Hour Density:
Table of Contents

Advertisement

3 CONNECTIONS

3-3 Connecting the Rear Panel Input/Output Terminal Connections

[CAM SW OUT] camera switching signal output terminal
CAM SW
OUT
COM
[ALARM RESET] alarm reset terminal
ALARM
RESET
COM
Switch
[TAPE END OUT] tape end output terminal
TAPE
END OUT
COM
[CLOCK RESET] clock reset terminal
5
When setting the clock to the first VCR's clock
First VCR
Second VCR
CLOCK
CLOCK
OUT
COM
5
When setting the clock to the external master clock
First VCR
External
CLOCK
master clock
IN
16
Sequential switcher
camera switching
signal input
Vcc
Vcc: 5V–12V
Alarm lamp
External
interface
IN
COM
Second VCR
CLOCK
COM
IN
COM
[ALARM IN] alarm signal input terminal
ALARM
IN
[ALARM REC OUT] alarm recording mode signal output terminal
ALARM
RESET
Switch
[WARNING OUT] warning signal output terminal
WARNING
OUT
Last VCR
CLOCK
IN
COM
Last VCR
CLOCK
IN
COM
COM
Sequential switcher
alarm output
terminal
ALARM
REC OUT
COM
COM
External
interface
External interface example
Example: Lamp lights with HIGH signal
Power
supply
Control
signal
GND
5
Use appropriately rated devices.
Alarm
lamp
External
interface
Alarm lamp
(Lamp, etc.)
Relay

Advertisement