3 CONNECTIONS

3-2 System Using Sequential Switcher

Video camera
CCD
CCD
CCD
CCD
CCD
CCD
1
Connect video cameras and alarm sensor to a sequential switcher (frame switcher).
2
Connect the sequential switcher's (frame switcher) alarm signal output, camera switching signal input and video output to
the SR-9090U.
3
Connect the monitor's video/audio input connectors to the SR-9090U's video/audio output connectors.
4
When the connection is complete, connect the power plug to an AC 120 V, 50/60 Hz outlet.
5
Synchro should be applied to all connected video cameras.
6
If you are connecting the camera switching signal input from a sequential switcher (frame switcher) to the SR-9090U, be
sure to set the <CAMERA SW> menu switch.
1
2
3
4
Alarm signal output
Video output
RCA
BNC
R S - 2 3 2 C
VIDEO
AUDIO
IN
REMOTE
MIC
OUT
RCA
BNC
4pin
Monitor TV
5
6
Alarm sensor input
1 2 3 4 5 6
Sequential switcher
Camera switching
signal input
Amplifier
AC~IN
AC120V~50/60Hz
Y/C
CAM SW
ALARM
ALARM
COM
CLOCK
SERIES
REC OUT
RESET IN
REC IN
OUT
IN
ALARM
TAPE
WARNING
CLOCK
SERIES
COM
RESET
END OUT
OUT
RESET OUT
REC OUT
ALARM IN
CAM SW
OUT
Alarm sensor
Microphone
Provided
power cord
AC 120 V
50/60 Hz