Unpacking; Service; Description; Power - Bosch LTC 5136/61 Instruction Manual

Ltc 5136 series autodome controller
Table of Contents

Advertisement

LTC 5136 Series | Instruction Manual | Unpacking
1

UNPACKING

This electronic equipment should be unpacked and
handled carefully.
Check for the following items:
LTC 5136/61 or LTC 5136/51 Desktop
Controller.
Interface unit.
Power supply.
Power supply cable.
One (1) 3 m (10 ft) cable with two (2) RJ-11
connectors.
If an item appears to have been damaged in shipment,
replace it properly in its carton and notify the shipper.
If any items are missing, notify your Bosch Security
Systems, Inc. Sales Representative or Customer

Service.

The shipping carton is the safest container in which the
unit may be transported. Save it for possible future use.
2
SERVICE
If the unit ever needs repair service, the customer should
contact the nearest Bosch Security Systems, Inc. Service
Center for authorization to return and shipping
instructions.

Service Centers

U.S.A.: Phone: 800-366-2283 or 408-956-3895
fax:
800-366-1329 or 408-956-3896
e-mail:
NationalServiceCenter@ca.slr.com
Canada:
514-738-2434
Europe, Middle East & Asia Pacific Region:
32-1-440-0711
For additional information,
see www.boschsecuritysystems.com.
NOTE: Grounded wrist straps must be worn and
proper ESD safety precautions observed when
handling the electrostatic-sensitive printed circuit
boards.
Bosch Security Systems | 04 September 2003
3

DESCRIPTION

The LTC 5136 Series Controllers are designed for use
with the Bosch AutoDome Series cameras. They can
also be used to operate any of the conventional
Allegiant® Series of Receiver/Drivers.
The LTC 5136 Series controllers support control of all
AutoDome and Allegiant receiver/driver functions
including variable speed pan/tilt/zoom, pre-positions,
auxiliaries, etc. Typically, one of the 16 outputs of the
LTC 5136 junction box is connected to a single
AutoDome camera or receiver/driver. If the application
will use a daisy chain wiring configuration, up to eight
(8) camera sites can be controlled from each of the 16
biphase outputs.
The biphase control code cable can extend a
maximum distance of 1.5 km (5000 ft), using
2
1.0 mm
(18 AWG) shielded twisted pair cable
(Belden 8760 or equivalent).
3.1

Power

The model number and operating voltage are shown
on the product label.
Model No.
Rated Voltage
LTC 5136/51
230 VAC, 50/60 Hz
LTC 5136/61
120 VAC, 50/60 Hz
EN | 9
Voltage
Power at
Range
Rated Voltage
195.5 to 253
6 W
105 to 132
6 W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ltc 5136/51

Table of Contents