SOLIS RHI-1P5K-HVES-5G Instruction Manual

SOLIS RHI-1P5K-HVES-5G Instruction Manual

Hybrid inverter

Advertisement

Ginlong Technologies Co., Ltd.
No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo,
Zhejiang, 315712, P.R.China.
Tel: +86 (0)574 6578 1806
Fax: +86 (0)574 6578 1606
Please adhere to the actual products in case of any discrepancies in this user manual.
If you encounter any problem on the inverter, please find out the inverter S/N
and contact us, we will try to respond to your question ASAP.
ComplywithCARule21/
SunSpec
CertifiedtoUL1741SA
Certified
Certified to UL Std. No. 1741-Second Edition
& CSA-C22.2 No.107.1-16
Solis RHI-HV Series Hybrid Inverter
Instruction Manual
Ginlong Technologies Co., Ltd.
(ForUSA)
Ver 1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RHI-1P5K-HVES-5G and is the answer not in the manual?

Questions and answers

Summarization of Contents

1. Introduction
1.1 Product Description
Detailed description of the Solis RHI-HV 5G series hybrid inverters.
1.2 Packaging
Lists the items included in the inverter packaging.
2. Safety & Warning
2.1 Safety
Explains safety symbols (DANGER, WARNING, CAUTION, NOTE) and their meanings.
2.2 General Safety Instructions
Provides essential safety instructions for installation and maintenance.
2.3 Notice For Use
Outlines conditions and guidelines for inverter installation and use.
3. Overview
3.1 Screen
Describes the 7-inch color screen for status and settings.
3.2 Keypad
Details the four keys on the front panel for navigation and control.
3.3 Terminal Connection
Explains terminal connections for the inverter before initial setup.
4. Installation
4.1 Select a Location for the Inverter
Criteria for choosing a suitable installation location for the inverter.
4.2 Mounting the Inverter
Step-by-step guide on how to mount the inverter vertically.
4.3 PV Input Terminals
Instructions for connecting PV strings to the inverter terminals.
4.4 AC Terminals Assembly
Steps for connecting AC cables to the inverter terminals.
4.5 Battery Terminals
Details on connecting battery power cables to fuse terminals.
4.6 Communication Ports
Overview of communication terminal ports and their uses.
4.7 External Grounding
Procedure for connecting the external grounding conductor.
4.8 LED Status Indicators
Explanation of the Red, Green, and Orange LED indicators and their meanings.
5. Operation
5.1 Initial Setup Display
Initial setup screen for language selection upon powering up.
5.2 Main Menu Navigation
Overview of the four main menu options: Information, Settings, Advanced Information, Advanced Settings.
5.3 System Information
Accessing operating data, general info, system info, energy records, BMS, and meter info.
5.4 General Settings
Options to modify Time/Date, Slave Address, and Language.
5.4.1 Set Time and Date
Guide to setting the inverter's time and date for accurate yield calculation.
5.4.2 Set Slave Address
How to set the slave address for the inverter.
5.4.3 Set System Language
Procedure for selecting the system language (English or Chinese).
5.5 Advanced Information Access
Viewing detailed information like Alarm, Warning, Running Status, and Communication Data.
5.5.2 Warning Messages
Displays abnormal warnings that do not cause inverter shutdown.
5.5.3 Running Status Details
Provides maintenance information like internal temperature and status.
5.5.4 Communication Data
Displays internal communication data for maintenance personnel.
5.5.5 Yield Profile Data
Viewing historical energy generation records like monthly, yearly, and total energy.
5.6 Advanced Settings (Technicians Only)
Restricted section for advanced configuration by authorized technicians.
5.6.1 Grid Standard Selection
Selecting the appropriate grid standard for inverter operation.
5.6.2 Start/Stop Generation
Function to start or stop the inverter's power generation.
5.6.3 Battery Management
Selecting compatible batteries and configuring battery wakeup settings.
5.6.4 Backup Port Control
Setting up the configuration for the backup port.
5.6.4.2 Backup Port Settings
Displays and allows modification of backup port parameters.
5.6.5 Storage Energy Configuration
Configuring meter selection and storage mode settings.
5.6.5.1 Meter Selection
Selecting the appropriate meter type for system configuration.
5.6.6 STD Mode Settings
Reserved settings for maintenance personnel, impacting inverter performance.
5.6.6.1 Working Mode Configuration
Selecting and configuring inverter working modes based on grid standards.
5.6.6.2 Volt-Watt Mode
Adjusting active output power based on voltage changes.
5.6.6.3 Volt-Var Mode
Modifying reactive output power according to voltage variations.
5.6.6.4 Fixed Power Factor
Setting a fixed power factor for inverter operation.
5.6.6.5 Reactive Power (Not Required)
Inverter generates reactive power based on changing output power.
5.6.6.6 Power Factor Adjustment (Not Required)
Inverter adjusts power factor based on changing output power.
5.6.6.7 Voltage-Watt UL Mode
Adjusting active output power based on voltage changes for UL1741SA.
5.6.6.1.2 Rule21 Standard Working Modes
Specific working modes for Rule21 grid standard compliance.
5.6.6.2 Ramp Rate Limit Control
Controls the power ramp-up rate during inverter initialization or MPPT changes.
5.6.6.3 Frequency Derating Settings
Setting frequency derating parameters for UL and Rule21 standards.
5.6.6.4 10-Minute Voltage Setting
This function is disabled and not used for the US market.
5.6.6.5 Reset to Initial Settings
Resets working modes to their default values.
5.6.7 Software Update Procedure
Updating the inverter's HMI and DSP firmware.
5.6.8 Export Power Control
Configuration of export power control, including backflow power and ON/OFF settings.
5.6.8.3 Failsafe Function
Shuts down the inverter if communication is lost with the meter and backflow power exceeds limits.
5.6.9 Data Calibration
Loading total generation data for maintenance or replacement scenarios.
5.6.10 User Password Reset
Allows users to reset the inverter's user password.
5.6.11 Restart HMI Display
Function to reboot the inverter's LCD screen.
6. Commissioning Process
6.1 Commissioning Preparations
Checks and confirmations required before starting the commissioning process.
6.2 Commissioning Steps
Step-by-step guide to safely start up the inverter for the first time.
7. Troubleshooting Guide
7.1 General Troubleshooting
Guidance on identifying and resolving inverter faults through the LCD and status indicators.
7.2 Alarm Message Diagnosis
Steps to diagnose faults by reviewing alarm messages in the advanced information section.
7.3 Fault Message Reference
A table listing alarm messages, failure descriptions, and solutions.
8. Product Specifications
8.1 Technical Data
Detailed technical specifications for the RHI-1P5K-HVES-5G and RHI-1P7.6K-HVES-5G models.
8.2 Grid Side AC Output Specs
Performance specifications related to the AC grid output.
8.3 Efficiency Ratings
Information on the inverter's maximum and EU efficiency ratings.
8.4 Protection Features
Details on built-in protection features like ground fault and AFCI.
8.5 General Inverter Data
General physical and operational characteristics of the inverter.
8.6 PV Input Specifications
Specifications for the DC input from PV modules.
8.7 Battery Specifications
Technical details regarding battery compatibility and capacity.
8.8 Key Features
Key features of the inverter including connections, display, and warranty.
9. Appendix
9.1 Grid Topology Solutions
Diagrams and instructions for connecting the inverter to various grid topologies.
9.2 Special Grid Topology
Information on special grid topologies not covered by standard configurations.

Table of Contents

Save PDF