Primes PMT 120 Operating Manual

Primes PMT 120 Operating Manual

Pocketmonitor pmt
Table of Contents

Advertisement

Quick Links

Operating Manual
Translation of the original instructions
PocketMonitor PMT
PMT 01p, 01p sep, 01p sep/out
PMT 05p, 05p sep, 05p sep/out
PMT 30p, 30p sep, 30p sep/out
PMT 70iag, 70iag sep, 70iag sep/out
PMT 70icu, 70icu sep, 70icu sep/out
PMT 120iag, 120iag sep, 120iag sep/out
PMT 120icu, 120icu sep, 120icu sep/out
Revision 01/2020 EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PMT 120 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Basic Safety Instructions for PocketMonitor PMT
Intended Use and Regulatory Compliance
Defines the device's purpose, improper usage, and emphasizes regulatory compliance.
Safety Measures and Personnel Requirements
Covers protective measures, qualified personnel, and liability disclaimers.
PocketMonitor PMT Symbol Explanation
Risk Signal Words and Symbols
Explains danger, warning, caution, notice signal words and their associated symbols.
Device and Operational Symbols
Details symbols for operation, information, and conformity (CE).
Manual Overview and Installation Site Conditions
Operating Manual Content
Describes the content and scope of the operating manual.
Installation Site Environmental Requirements
Specifies non-condensing atmosphere, no organic gases, and protection from water/dust.
Lithium-ion Battery Handling and Disposal
Battery Storage, Damage, and Replacement
Guidelines for storing, handling potential damage, and battery replacement.
Proper Battery Disposal Procedures
Instructs on proper methods for disposing of the device's battery according to regulations.
Introduction to PocketMonitor PMT System
System Description and Components
Explains device components, connections, and optional interfaces like current loop.
Measuring Principles and Device Type Differentiation
Calorimetric Measurement Principle
Explains the calorimetric principle used for laser power measurement.
Device Type Differentiation Methods
Details differentiation by laser power, absorber type, and mechanical construction.
Transportation and Handling Guidelines
Safe Handling and Packaging for Transport
Advises careful handling, closing the unit, and using the original transport box.
Connecting the PocketMonitor PMT
Cable Connection for Sep/Sep-out Models
Explains connecting calibrated components using serial numbers for sep/sep-out types.
Analog Current Loop Interface Connection
Details connecting the analog current loop interface via a 5-pin socket and its pin functions.
Installation and Removal Procedures
Installation Preparation and Mounting Position
Covers switching off laser, preparing installation, and choosing mounting position.
Laser Beam Alignment Procedure
Explains how to align the device with the laser beam for accurate measurement.
System Placement and Safe Removal
Guides on positioning the device within the laser system and safe removal procedures.
PocketMonitor PMT Control Elements and Operation
Operating Unit and Button Functions
Details the operating unit and the functions of control buttons like 10s, 20s, TEMP.
Device Display Information and Resolution
Lists display resolution and measuring steps for various PMT models.
Measuring with the PocketMonitor PMT
Critical Measurement Safety Instructions
Outlines critical safety precautions during measurement, including laser radiation hazards.
Maximum Permissible Laser Power Limits
Specifies power limits based on irradiation time and provides a reference table.
Operating Unit Measurement Procedure
Details preparation steps before taking measurements via the operating unit.
Performing Measurement via Operating Unit
Explains the step-by-step procedure for performing measurements using the operating unit.
Analog Current Loop Interface Measurement Procedures
Preparation for Analog Interface Measurement
Steps to prepare for measurements using the analog current loop, including safety and connection.
Laser Power Measurement via Analog Interface
Details measuring laser power via analog interface and calculating it using output current.
Absorber Temperature Measurement via Analog Interface
Explains measuring absorber temperature via analog interface and calculating it using output current.
Absorber Cooling and Error Handling
Cooling Absorber for Series Measurements
Provides instructions for cooling the absorber between measurements to maintain accuracy.
Troubleshooting Common Measurement Errors
Lists common errors and their potential causes for effective troubleshooting.
Maintenance and Product Disposal
Recommended Maintenance Intervals
Recommends maintenance and calibration intervals for the device's longevity.
Product Disposal Regulations and Procedures
Outlines obligations and procedures for product disposal in the EU.
Declaration of Conformity
EC Declaration Compliance Details
States the device's conformity with relevant EC directives and RoHS regulations.
Technical Data for Device Types
Device Type 'p' Specifications
Lists technical data like laser power range, wavelength, and beam diameter for 'p' type devices.
Device Type 'icu/iag' Specifications
Lists technical data for icu/iag types including power, wavelength, and dimensions.
Environmental and Protection Specs
Details operating/storage conditions and protection ratings for various device types.
Device Dimensions
PMT 01p and 01p sep/out Dimensions
Provides dimensional drawings and measurements for PMT 01p and its sep/out variants.
PMT 05p and 05p sep/out Dimensions
Provides dimensional drawings and measurements for PMT 05p and its sep/out variants.
PMT 30p and 30p sep/out Dimensions
Provides dimensional drawings and measurements for PMT 30p and its sep/out variants.
PMT 70icu/iag and sep/out Dimensions
Provides dimensional drawings and measurements for PMT 70icu/iag and their sep/out variants.
PMT 120icu/iag and sep/out Dimensions
Provides dimensional drawings and measurements for PMT 120icu/iag and their sep/out variants.

Table of Contents