Diagnostic Testing - Visonic POWERMAXCOMPLETE PANEL Quick Manual

Panel, fully supervised wireless alarm control system
Hide thumbs Also See for POWERMAXCOMPLETE PANEL:
Table of Contents

Advertisement

MESSAGES THAT MAY BE REPORTED TO INSTALLER AFTER TEST:
LCD MESSAGE
Unit is Ok
1
GSM Com. Loss
2
Pin Code Failure
3
GSM net. failure
4
SIM card failure
5
GSM not enrolled
6
No GPRS service
7
GPRS Conn. Fail
8
Srvr Unavailable
9
Srvr IP Missing
10
APN Is Missing
11
SIM Card Locked
12
Denied By Server
13
Note 1: After SIM card provisioning, the control panel must be power cycled!

15. DIAGNOSTIC TESTING

10
GSM (Global System for Mobile Communications) / GPRS (General Packet Radio
Service) is working properly
RS-232 communication with modem failed
Missing or wrong PIN Code. (Only if SIM card PIN Code is enabled.)
Modem failed registration to local GSM network (+Creg ...)
SIM card is not installed correctly in GSM Modem
GSM auto enroll failed to detect GSM modem
GPRS network is not available to work with the current SIM card, meaning the
SIM card is not open for GPRS. (CGATT). (See note 1)
Local GPRS network is not available or wrong.
GPRS APN, User and Password. (AT+GPRS).(See note 1)
Fail opening TCP socket with server. Problem with server or wrong server IP or
no acknowledge received from server. (AT#SKTD)
Server IP # 1 and #2 are not configured
APN (Access Point Name) is not configured
After entering a wrong pin code 3 consecutive times, the SIM is locked. To unlock
it a PUK (Pin Unlock Key) number should be entered. The PUK cannot be entered
by the PowerMax.
(This can be fixed by installing the SIM in a personal cellphone and performing the unlock function)
The IPMP replied "DUH" to SIA-OVER-IP event message. "DUH" means that the
IPMP cannot handle the message because the panel is not defined or the
message is not decrypted correctly.
Action(s)
1.
Enter into installer
menu (see par. 8)
2.
Press
9 times
3.
Press
4.
Press
5.
Walk test the entire
protected site to trigger all
the sensors.
6.
Review all the results by
pressing
repeatedly
to see all the results.
If you get a "POOR" display
from a certain sensor, relocate
it and re-test until the result is
"GOOD" or "STRONG".
DESCRIPTION
Resultant Display
10. DIAGNOSTICS
WL SENSORS TEST
DIAG. TESTING
FRONT DOOR
Alternately
Z1 STRONG
BACK DOOR
Alternately
Z2 GOOD