Defining Zone Types, Names, Chime Zones & Partition - Visonic POWERMAX PRO Installer's Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMAX PRO:
Table of Contents

Advertisement

4.3 DEFINING ZONE TYPES, NAMES, CHIME ZONES & PARTITION
This mode allows you to assign one of 15 zone types to
each of the system's 30 (wireless & wired) zones. You can
define zones as KEY ZONES, to enable arming/disarming
of the system by PowerCode transmitters (see appendix
D14). In addition, it also allows you to assign a name and
partition number (up to three) to each zone and determine
whether the zone will operate as a chime zone. When a
chime zone is triggered, chime melody or zone name is
heard (there are 3 selectable chime modes - Melody chime,
Zone Name Chime or Chime Off).
READY
First display
WALK TEST
USER SETTINGS
INSTALLER MODE
ENTER CODE
[installer code]
2. ENROLLING
3. DEFINE ZONES
15. PARTITIONING
<OK> TO EXIT
*
The currently saved option is displayed with a dark box at the right side. To review the options, repeatedly click
or
at the right side).
** Key ON/OFF is an optional function that enables you to arm or disarm the system via zones 21-28, 29 or 21-29, provided
that "non-alarm" was pre-defined for these zones.
D-302541
31 zone names can be selected, 26 fixed names and 5 custom names (defined by
the installer - see chap. 4.9):
Attic
Back door
Basement
Bathroom
Bedroom
Child room
Closet (UK: Conservatory)
Den (UK: Playroom)
: - -
ZONE No
[Zone No.] (e.g. 05)
Zxx: TYPE -
1. Inter-follow
2. Perimeter
3. Perim-follow
4. Delay 1
5. Delay 2
6. 24h silent
7. 24h audible
8. Fire
9. Non-alarm
10. Emergency
11. Gas
12. Flood
13. Interior
14. Temperature
15. Home/Delay
(*)
Zxx: CHIME
Melody-chime
Zone name-chime
Chime off
(*)
Figure 4.3 - DEFINE ZONES Flow Chart
button, until the desired option is displayed, then click
A list of factory defaults is printed in table 1. You may fill
out the blank columns even before you start and proceed
to program according to your own list.
Remember!
A delay zone is also a perimeter zone by definition.
Zone types are fully explained in Appendix D.
Note: Custom Zone Name text can be changed through
the DEFINE VOICE menu.
Selectable Zone Names
Dining room
Hall
Downstairs
Kitchen
Emergency
Laundry room
Fire
Living room
Front door
Master bath
Garage
Master bdrm
Garage door
Office (UK: Study)
Guest room
Upstairs
(**)
OPTIONAL
If Non-alarm is selected
Zxx: KEY ON/OFF
z-key enable
z-key disable
(*)
(see note)
Zxx: PARTITION
[Zone No.] (e.g. 05)
Z05: P1
P2
P3
(*)
Utility room
Yard (UK: Garden)
Custom 1
Custom 2
Custom 3
Custom 4
Custom 5
Zxx: NAME - -
Attic
Back door
Basement
Bathroom
Bedroom
Child room
Closet
(see list above)
(*)
(a dark box will be displayed
13