Thermo Scientific TSX505SA Installation And Operation Manual

Thermo Scientific TSX505SA Installation And Operation Manual

5.5 cu.ft. undercounter refrigerator

Advertisement

5.5 cu.ft. Undercounter
Refrigerator
TSX Series
Installation and Operation
328277H01
Rev. A
April 2017
Visit us online to register your warranty
www.thermoscientific.com/labwarranty

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TSX505SA and is the answer not in the manual?

Questions and answers

Summary of Contents for Thermo Scientific TSX505SA

  • Page 1 5.5 cu.ft. Undercounter Refrigerator TSX Series Installation and Operation 328277H01 Rev. A April 2017 Visit us online to register your warranty www.thermoscientific.com/labwarranty...
  • Page 2 IMPORTANT Read this instruction manual. Failure to follow the instructions in this manual can result in damage to the unit, injury to operating personnel, and poor equipment performance. CAUTION All internal adjustments and maintenance must be performed by qualified service personnel. Material in this manual is for informational purposes only.
  • Page 3: Table Of Contents

    Table of Contents Table of Contents Product Specifications .............1 Models ..................1 General Specifications and Features ........1 Physical Dimensions ............2 Agency Approvals ..............2 Data Monitoring and Lodging ..........2 Environmental Operating Conditions ........2 Safety Precautions..............3 Wiring Diagram ...............6 Unpacking the TSX Refrigerator ...........7 Inspecting for Damage ............7 Unboxing and Locating ............7 Identifying all Parts ..............7...
  • Page 4 Table of Contents Adjustable Shelving ............18 Navigating TSX 5.5 Cu.Ft. Refrigerator Controls....19 System Icons ..............19 System Prompts ..............19 System Alerts ..............20 System Alert Values ............20 Reading the LCD (Temperature) Display ......20 Login and Unlock Door .............21 Login ................21 Unlock/Lock Door............22 Access the Main Menu ............22 Alarms ................22 Data Log.................23...
  • Page 5: Product Specifications

    Solid door 2.7 kWh/24 hrs @ 4°C set point and 25°C ambient Insulation CFC-free insulation Display Full-color 4.5” LCD with LED backlighting Power Cord 1.8 meter, NEMA hospital grade plug Noise Level 35 dBA Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 6: Physical Dimensions

    Operating Conditions Maximum ambient temperature 18°C – 32°C Humidity requirements Low humidity. Not for outdoor use Warranty 2 years on all parts and labor, 7 years on thermoelectric heat pumps part Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 7: Safety Precautions

    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 8 RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 9 CAUTION: Any modifications made to this device that are not approved by Thermo Scientific may void the authority granted to the user by the FCC to operate equipment. CAUTION: Cells/batteries shall be tested and pass applicable regulations based on type and use such as: •...
  • Page 10: Wiring Diagram

    Wiring Diagram 3 Wiring Diagram Figure 1. Wiring diagram for TSX 5.5 cu.ft. Undercounter Refrigerator Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 11: Unpacking The Tsx Refrigerator

    To remove the bottom foam protectors, carefully tip the unit to one side and remove the opposite side foam piece (repeat for other side piece). 4.3 Identifying all Parts Figure 2. Parts of the Refrigerator Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 12: Installation

    They do not run constantly. If the fans run frequently, the product may require more space for ventilation. Please refer to the section on how to clean and troubleshoot the fan for more information. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 13: Power On And Power Cord Guidelines

    To function properly the refrigerator must continually receive power. Caution, risk of electrical shock. If the cord or plug becomes damaged, replace with a cord and plug of the same type and rating. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 14: Uninterruptable Power Supply (Ups)

    UPS is to provide short-term power when the input power source fails. If you use a UPS backup, take care to follow the directions and precautions accompanying that device. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 15: Operation

    3. The level of the propylene glycol in the bottle is full. In the event that the bottle has broken during shipping, contact our service department for a replacement bottle. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 16: Preprogrammed Settings

    Reaching Glycol set point temperature will take longer. When the unit is first plugged in and powered, the Temperature Range Alarms are not enabled until the unit reaches its preset temperature range + an offset of Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 17: Loading Products For The First Time

    24 hours. During the defrost cycle you will likely hear the fan turning off and on. Cycles In addition to the automatic defrost cycles, you can initiate a manual defrost cycle through the Settings menu. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 18: Getting To Know Your Product

    Verify that the port is intact by inserting the USB drive (not included) and looking for the USB icon in the icon bar at the top of the LCD display. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 19: Ventilation

    1. Log in to the refrigerator using the PIN. 2. Touch the unlock button on the home screen. 3. The door will now be unlocked. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 20 Note While tightening the screws you may experience increased resistance before the screws are flush with the bracket. This is normal, apply a moderate level of torque until the screws are properly seated. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 21: Product Exterior - Rear

    Putty may also be used to help reseal the area. The evaporation tray is located on the bottom rear of the unit. 7.2.2 Evaporation Tray 7.3 Product Interior Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 22: Interior Components

    Your TSX undercounter refrigerator is shipped with wire ties holding the shelves 7.3.2 Adjustable Shelving in place. Remove the wire ties before using the refrigerator. You may place the shelving wherever you choose by removing and relocating the support clips. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 23: Navigating Tsx 5.5 Cu.ft. Refrigerator Controls

    Navigating TSX 5.5 Cu.Ft. Refrigerator Controls 8 Navigating TSX 5.5 Cu.Ft. Refrigerator Controls 8.1 System Icons 8.2 System Prompts Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 24: System Alerts

    (Temperature) Display are displayed in every screen in the graphic user interface with the exception of the screen where an administrator, sub-administrator or user enters their password to unlock the door. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 25: Login And Unlock Door

    1. Tap the Login button to bring up the Password/Pin entry screen. 2. Tap in the appropriate 4-digit Password/Pin (a Universal Password/Pin is provided with the unit and must be entered upon the first/initial login). 3. Tap/Select the Check button. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 26: Unlock/Lock Door

    The Active Alarms screen displays a list of active alarms and is one of the ways 8.7.1.1 Active Alarms that an alarm can be cleared. Tap Active Alarms to access the Active Alarms display. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 27: Data Log

    Use the up or down arrow to scroll through the settings. Data log is part of the local temperature monitoring accessory and can be added 8.7.2 Data Log to any TSX refrigerator. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 28 USB drive OR the USB drive may have other files on the USB drive that interfere with the download. It is recommended that the same USB drive is used for continuous data downloads. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 29 OK. Note Clearing the data erases the memory and once erased, the data cannot be recovered. 8.7.2.5 Reviewing / Adjusting Data Log Settings Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 30: Settings

    Note The data log feature is part of the local temperature monitoring accessory and can be added to any TSX refrigerator. Visit Thermo Scientific.com for more information.
  • Page 31 If the user selects to set the date the user is prompted to enter the current date and can select from the US standard mm/dd/yy or the optional dd/mm/yy setting and selecting the check mark. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 32 Serial Number and battery health. This is an important area where the user can see the product Serial Number, MAC Address, IP Address and Firmware Versions. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 33: Administrator Tools

    Apply. The control will then display a screen acknowledging that the new, updated firmware is being applied. When the upload is complete the display screen will confirm that the new firmware has been successfully applied. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 34 Glycol. An example of calculating an offset value: Your NIST certified temperature reading is 3.7°C, the unit reading is 4.2°C, the offset would be -0.5°C. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 35: Periodic Product Maintenance

    The catch tray is found on the bottom rear of the exterior cabinet. The bottom shelf can be removed for periodic cleaning or when excessive moisture or spills effect the bottom of the unit. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 36: Frequently Asked Questions

    What is the product warranty? Thermo Scientific offers a 2-year product warranty on parts and labor and a 7-year warranty on the PHP part. Is the power cord healthcare/NEMA approved? Yes, it is a National Electrical Manufacturers Association (NEMA) approved plug (indicated by a green dot on the cable).
  • Page 37 As with any electrical or mechanical system, heat accumulation in a closed environment can impact the cooling performance of the refrigerator. We recommend adequate ventilation in the back wall of the cabinet to dissipate heat outside of the cabinet. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 38: Troubleshooting

    Once the refrigerator I can't hear any noise from the unit reaches its set point temperature then it will be very quiet during normal operating conditions. Installation and Operation Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator...
  • Page 39 USB icon appear on the icon bar. If it doesn't register after a few attempts, try inserting a different USB memory stick. Contact Thermo Scientific customer service if this persists. Did you confirm there is a USB icon on the icon bar? Is the LED...
  • Page 40: Product Warranty And Service

    Thermo Scientific shall cover the cost of parts and labor for repair and replacement, and ii. An additional period of 5 years with respect to the Thermo Scientific heat pump powering the refrigeration system, during which period Thermo Scientific shall cover the cost of replacement parts and shall charge Thermo Scientific’s standard labor rates for repair and...
  • Page 41 For any questions concerning this warranty please visit our website at Thermo Scientific.com or contact Customer Care at 866-984-3766. Thermo Scientific TSX 5.5 cu.ft Undercounter Refrigerator Installation and Operation...
  • Page 42: Weee Compliance

    Further information on our compliance with these Directives, the recyclers in your country, and information on Thermo Scientific products which may assist the detection of substances subject to the RoHS Directive are available at www.thermo.com/...
  • Page 43 (manufacturer or specific agent/rep organization), and purchase order number. IF YOU NEED ASSISTANCE: Thermo Scientific products are backed by a global technical support team ready to support your applications. We also offer cold storage accessories, including remote alarms, temperature recorders and validation services. Visit www.thermoscientific.com or call:...
  • Page 44 Thermo Fisher Scientific Inc. 275 Aiken Road Asheville, NC 28804 United States www.thermofisher.com 328277H01 Rev.A...

Table of Contents

Save PDF