Oval 56 Instructions Manual

High temp./low temp. service and jacketed smart ultra oval flowmeters, cooling tube provided

Advertisement

B-49-4N-E
Ins. No.
High Temp./Low Temp. Service and Jacketed
SMART ULTRA OVAL FLOWMETERS
Meter Sizes 50, 52, 53, 55, 56, and 57
Meter size 50
Cooling tube provided
Meter sizes 52, 53, 55, 56
Heating tube provided
Meter size 57
Cooling tube provided
Every SMART ULTRA OVAL is fabricated and shipped from our factory under stringent quality control. In
order to maintain its design performance throughout the life of the meter, this manual offers the operator the
necessary installation, operation and maintenance information.
Be well familiar with these instructions before you place the meter in service and keep this manual at the field
location for ready reference.
The standard, high temperature-service, low temperature-service, and jacketed type meters all have in
common the same specifications described in this instruction manual except for some differences in the
jacketed type on its piping procedure and operating precautions. Be careful to observe the instructions given
with a reminder "See also page 5 for the jacketed type".
◆ About Meter Size Designation ◆
The size of OVAL positive-displacement flowmeters is basically identified by a two-digit code. For complete
details, see Section 7 PRODUCT CODE EXPLANATION.


Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 56 and is the answer not in the manual?

Questions and answers

Summarization of Contents

1. BEFORE YOU BEGIN
1.1 Confirming the Tag
Verify product specifications against the register tag for compliance.
1.2 Transportation Considerations
Guidance on safe transport to prevent damage during transit.
1.3 Storage Considerations
Precautions for storing the meter to prevent faults during long periods.
1.4 Structural Considerations
Details on the register's waterproof construction and pressuretight packing.
5. LCD COUNTER DISPLAY
5.1 About "MODE" Switch
Instructions on using the selector magnet to change display modes.
5.2 Display Functions
Description of different flow information displayed and error messages.
5.3 Display Mode Selection
Methods for selecting display modes via switch or communications.
5.4 Total Counter Reset
Procedures for resetting the totalizer via switch or communication unit.
5.5 Considerations with Pulse Output Type
Notes on the inoperability period and communication requirements for pulse output models.
6. INSTALLATION
6.1 Considerations at Installation
Essential checks and precautions before and during meter installation.
6.2 Standard Installation, Horizontal Line
Diagram and steps for typical horizontal pipe installation.
6.3 Standard Installation, Vertical Line
Diagram and steps for typical vertical pipe installation.
6.4 Example of Faulty Piping
Illustrates incorrect meter installation positions to avoid.
8. WIRING INSTRUCTIONS
8.1 Wiring Guidelines
Recommendations for field wiring, transmission length, and interference prevention.
8.2 Terminal Connections
Details on accessing and connecting terminals for output signals.
8.3 Preamplifier-to-Receiving Instrument Hookup
Explains signal transmission methods and load resistance considerations.
9. OPERATING INSTRUCTIONS
9.1 Operation
Step-by-step procedure for initial operation and break-in.
9.2 Operating Precautions
Critical warnings regarding flow rate, temperature changes, and fluid types.
9.3 Precautions at Operation Shutdown
Guidelines for safe shutdown procedures to prevent damage.
9.4 About Register Life
Information on expected register lifespan and factors affecting it.
9.5 Piping Instructions and Operating Precautions of Jacketed Meters
Specific piping and operational advice for jacketed meter types.
10. DISASSEMBLY AND INSPECTION
10.1 Size 50 Meter Body Disassembly and Inspection
Step-by-step guide for disassembling and inspecting the Size 50 meter body.
10.2 Size 50 Meter Body Assembly Procedure
Detailed instructions for reassembling the Size 50 meter body.
10.3 Sizes 52, 53, 55, 56, 57 Meter Body Disassembly and Inspection
Guide for disassembling and inspecting meter bodies of sizes 52-57.
10.4 Sizes 52, 53, 55, 56, 57 Meter Body Assembly Procedure
Instructions for reassembling meter bodies of sizes 52-57.
11. REGISTER SWITCH FUNCTIONS AND PARAMETER SETTING
11.1 Switch Names and Functions
Identification and explanation of switches on the electronics unit.
11.2 Individual Test Pin Functions
Details on the function of each test pin on the electronics unit.
11.3 About Meter Factor
Procedure for determining and applying a new meter factor.
14. EXPLODED VIEWS AND PARTS LIST
14.1 Meter Size 50 Exploded View and Parts List
Diagram and list of parts for the Size 50 meter body.
14.2 Meter Sizes 52 and 53 Exploded View and Parts List
Diagram and list of parts for meter sizes 52 and 53.
14.3 Meter Sizes 55 and 56 Exploded View and Parts List
Diagram and list of parts for meter sizes 55 and 56.
14.4 Meter Size 57 Exploded View and Parts List
Diagram and list of parts for meter size 57.