When the STATUS Indicator is Lit/Blinks
When the STATUS indicator of the
main unit operation panel is lit or
blinks, notification is being given of
the irregularities described.
STATUS Indicator
STATUS
Blinks red
(0.5 s lit / 0.5 s off)
STATUS
Blinks red
(1 s lit / 1 s off)
STATUS indicator
POWER Indicator
POWER
Lit red
POWER
When the lamp burns out during operation: Blinks amber for 90 seconds
and then is lit amber
When the lamp does not light from the beginning: Lit amber
E-31
A U
D I O
V I D
E O
Action to Take
The temperature has become abnormally high.
* The thermal protector is activated. If the room
temperature is high, move the projector to a cool
location. If the internal temperature of the pro-
jector is high, check the ventilation holes of the
cooling fan and clean them if they are obstructed.
* When the thermal protector is activated, the
power is switched off and even if the power is
soon switched back on, the power might not
actually be supplied to the projector. Should this
happen, wait one minute and then switch the
power on again.
If the power still does not come on, wait approxi-
mately 60 minutes until the internal temperature
of the projector drops, then switch on the power
again.
When the aforementioned procedure does not
solve the problem, please contact Olympus Digi-
tal Technical Support.
The lamp will not light up.
Wait one minute or longer while the lamp lighting
voltage irregularity detection protector is activated
and switch the power on again. If the problem still
persists, unplug the power cable and contact
Olympus Digital Technical Support.
POWER indicator
Need help?
Do you have a question about the VP-1 - Data Projector - DLP and is the answer not in the manual?