CPE On-Line Series Quick Install Procedure

Please read all of the WARNINGS, CAUTIONS and the User's Manual before attempting to
install or service the UPS.
WARNING: This UPS contains potentially hazardous voltages. Risk of Electrical shock. The internal batteries
energize hazardous live parts inside this UPS even when the AC input power is disconnected.
NOTE: Installing or Servicing of the UPS must be performed by Qualified Service Personnel ONLY. MINUTEMAN
accepts no liabilities and is not limited to: injury to the Service Personnel, or damages to; the UPS, or the connected
equipment caused by the incorrect installation or servicing of the UPS.
NOTE: These UPSs are shipped with the batteries disconnected. The batteries must be connected before putting these
UPSs into service.
CAUTION: Although battery system voltages are 36VDC, 72VDC and 96VDC the battery system can still present a risk
of electrical shock. These batteries produce sufficient current to burn wire or tools very rapidly, producing molten metal.
Observe these precautions when installing or servicing the batteries:
1.
Remove watches, rings, or other metal objects.
2.
Use hand tools with insulated handles.
3.
Wear protective eye gear (goggles), rubber gloves and boots.
4.
Do not lay tools or other metal parts on top of batteries.
5.
Disconnect the charging source prior to connecting or disconnecting the battery terminals.
6.
Determine if the battery is inadvertently grounded. If the battery is, remove the source of the grounding. Contact
with any part of a grounded battery can result in an electrical shock. The likelihood of such shock will be reduced, if
such grounds are removed during installation and maintenance.

INSTALLATION

Be sure to read the installation placement and all the cautions before installing the UPS. Place the UPS in the final
desired location and complete the rest of the installation procedure. These UPSs are shipped with the internal batteries
disconnected. The batteries must be connected before putting these UPSs into service. Follow the procedure below to
connect the batteries. USE CAUTION: The UPS is heavy. Use the appropriate number of personnel when installing the
UPS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CPE 2000 and is the answer not in the manual?

Questions and answers

Summarization of Contents

CPE On-Line Series Quick Install Procedure
Safety and Warning Information
Details hazardous voltages, qualified personnel requirements, and battery handling precautions.
Initial Installation Steps
Covers UPS placement and the initial process of connecting internal batteries.
Step-by-Step Installation and Operation
Connecting UPS and Load
Steps for unboxing, connecting UPS input/output, and connecting equipment.
Powering On and Self-Test
Instructions for turning on the UPS, verifying indicators, and performing a self-test.
Front Panel Controls and Indicators
Control Switch and LED Functions
Explains the main switch for UPS operation and the meaning of various status LEDs.

Table of Contents