USER GUIDE | UG:017
Analog Control 3623 and 4623 ChiP DCMs
Evaluation Board
Arthur Russell
®
VI Chip
Applications Engineering
October 2014
Contents
Page
Introduction
Contents
Features
Board Description
General Components
Test Points Description
Schematic, Assembly Drawing
and Bill of Materials
Recommended Test
Equipment
Basic Connections
Board Operation Details
Trim Control
Fault Monitoring
Chassis Ground
16
Paralleling
16
Introduction
1
The Analog Control 3623 and 4623 ChiP DCM evaluation boards described in this document are
designed to be used with the DCM family of isolated, DC-DC converters. The 3623 DCM board is used
3
for the analog control, low input voltage 3623 ChiP products, while the 4623 DCM board is used for
3
the analog control, high input voltage (offline) 4623 ChiP products.
4
The DCM evaluation board can be configured for various enabling and fault monitoring schemes,
as well as to exercise various modes of trimming, depending on the application requirements. The
4
evaluation board can be used to evaluate DCMs in either a stand-alone configuration, or as an
6
array of modules.
7
Enable options:
1.
On-board mechanical switch (default)
14
2.
External control
14
14
Trim options:
15
1.
Fixed trim operation (default): the TR pin is permitted to float at initial startup.
15
The DCM disables output trimming and the output trim is programmed to the nominal rated V
2.
Variable trim operation, on-board variable resistor: The trim pin voltage is ratiometric,
with a rheostat working against a pull-up resistor inside the DCM to VCC.
3.
Variable trim operation, off-board control: The trim pin voltage is controlled via external
programming control, which is referenced to the –IN of each specific DCM in the system.
Fault monitor options:
1.
On-board LED: the FT pin drives a visible LED for visual feedback on fault status.
2.
On-board optocoupler: the FT pin drives an on-board optocoupler to bring
fault status across the primary-secondary isolation boundary.
UG:017
vicorpower.com
Applications Engineering: 800 927.9474
.
OUT