Allen-Bradley 1738-AENTR User Manual

Allen-Bradley 1738-AENTR User Manual

2 port ethernet/ip adapters
Table of Contents

Advertisement

POINT I/O and ArmorPOINT I/O 2 Port
EtherNet/IP Adapters
Catalog Numbers 1734-AENTR, 1738-AENTR
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1738-AENTR and is the answer not in the manual?

Questions and answers

Summarization of Contents

Preface
Who Should Use this Manual
Identifies the target audience for this user manual.
Where to Find More Information
Lists additional Rockwell publications for reference.
Chapter 1 About the Adapters
Overview
Provides an overview of the adapters, their features, and usage.
Important Adapter Considerations
Key factors to note before using the adapter.
About the POINT I/O and ArmorPOINT I/O 2 Port Adapters
Details on POINT I/O and ArmorPOINT I/O adapters.
Set the Chassis Size
Procedure for configuring the adapter's chassis size.
Adapter Replacement
Guidelines for replacing an adapter.
Empty Slots and RIUP Situations
Handling empty slots and removal/reinsertion under power.
Power Up a System for the First Time
Steps for initial system power-up and addressing.
Adapter Features
Key features of the adapters.
Hardware/Software Compatibility
Compatibility information for firmware and software.
What the Adapter Does
Primary tasks performed by the I/O adapters.
Use of the Common Industrial Protocol (CIP)
Explanation of CIP usage for EtherNet/IP.
Understand the Producer/Consumer Model
Concept of producer/consumer networking.
Chapter 2 Install Your Adapter
Overview
Describes physical installation and network connection procedures.
Identify Adapter Components
Using figures to identify adapter features.
Mount the I/O Adapter
Procedures for mounting the I/O adapters.
Mount the POINT I/O Adapter on a DIN Rail
Steps to mount the adapter on a DIN rail.
Mount the ArmorPOINT I/O Adapter and Base on a Wall or Panel
Mounting instructions for ArmorPOINT adapter.
Drilling Dimensions
Drilling layout for ArmorPOINT adapter mounting.
Terminal Base
Details of the terminal base components.
Install the POINT I/O Adapter Module
Procedure for installing the POINT I/O adapter module.
Install the ArmorPOINT I/O Adapter Module
Procedure for installing the ArmorPOINT I/O adapter module.
Wire the POINT I/O Adapter
Wiring instructions for the POINT I/O adapter.
Wire the ArmorPOINT I/O Adapter
Wiring instructions for the ArmorPOINT I/O adapter.
1738-AENTR EtherNet/IP Connectors
Pinout for 1738-AENTR EtherNet/IP connectors.
1738-AENTR Auxiliary Power Connector
Pinout for 1738-AENTR auxiliary power connector.
Chapter 3 Configure the Adapter for Your EtherNet/IP Network
Overview
Describes configuration requirements and procedures for network setup.
Configuration Requirements
Essential IP, subnet mask, and gateway settings.
IP Address
Explanation of IP addressing and classification.
Gateway Address
Role of gateway addresses in multi-network systems.
Subnet Mask
Function of subnet masks for network segmentation.
Set the Network Address
Methods for setting the network address.
Set the Network Address for POINT I/O Adapter
Using thumbwheel switches for address setting.
Set the Network Address for ArmorPOINT I/O Adapter
Using front switches for address setting.
Use the Rockwell BootP/DHCP Utility
Configuring adapters using the BootP/DHCP utility.
Save the Relation List
Saving configuration data for future use.
Use DHCP Software to Configure Your Adapter
Using DHCP for dynamic IP assignment.
Chapter 4 Configure the Adapter for Direct Connection in RSLogix 5000 Software
Overview
Example of controller communicating via direct connection.
Set Up the Hardware
Setting up the ControlLogix chassis and adapter.
Create the Example Application
Steps to create a new project in RSLogix 5000.
Configure the I/O
Adding modules to the I/O configuration.
Add the Local EtherNet/IP Bridge to the I/O Configuration
Configuring the EtherNet/IP bridge module.
Add the POINT I/O Adapter to the I/O Configuration
Adding the adapter as a child module.
Add the POINT I/O Modules to the I/O Configuration
Adding I/O modules to the adapter.
Add the Relay Output Module
Steps to add a relay output module.
Add the Digital Output Module
Steps to add a digital output module.
Edit the Controller Tags
Managing controller tags for I/O modules.
Create the Ladder Program
Developing a ladder program to test I/O.
Download the Program to the Controller
Transferring the program to the controller.
Verify the Module Chassis Size
Synchronizing chassis size between software and hardware.
Configure the Adapter with Fixed IP Address
Setting a static IP address for the adapter.
Recover From an Overloaded Adapter
Addressing adapter overload conditions.
Chapter 5 Configure the Adapter for Direct Connection and Rack Optimization in RSLogix 5000 Software
Overview
Configuring adapter with direct and rack-optimized connections.
Set Up the Hardware
Setting up the I/O hardware for the example.
Set Up the POINT I/O Hardware
Detailed hardware setup for POINT I/O.
Create the Example Application
Creating a new RSLogix 5000 project.
Configure the I/O Modules
Adding I/O modules to the configuration.
Add the I/O Adapter to the I/O Configuration
Adding the adapter to the I/O tree.
Add the POINT I/O Module and Configure For Direct Connection
Configuring modules for direct connection.
Download the Program to the Controller
Transferring the program to the controller.
Verify the Module Chassis Size
Ensuring chassis size synchronization.
Chapter 6 Interpret the Status Indicators
Overview
Information on LED status indicator meanings.
Interpret the Status Indicators
Understanding LED indicators for adapters.
Status Indicators for POINT I/O Adapter
Describes status indicators on the 1734-AENTR.
Status Indicators for 1734-AENTR Adapter
Detailed status descriptions for 1734-AENTR.
Status Indicators for ArmorPOINT I/O Adapter
Describes status indicators on the 1738-AENTR.
Appendix B Adapter Web Dialogs
Overview
Accessing adapter diagnostics via web dialogs.
Work with the Home Page
Navigating the adapter's home diagnostics page.
Work with the Diagnostics Pages
Accessing various diagnostic information pages.
Use the Diagnostic Overview Page
Viewing general diagnostic data.
Use the Network Settings Page
Configuring and viewing network parameters.
Use the Ethernet Statistics Page
Monitoring Ethernet link and interface counters.
Use the I/O Connections Page
Viewing CIP I/O connection information.
Use the Diagnostic Messaging Page
Executing explicit, unconnected message services.
Work with the Configuration Pages
Accessing adapter configuration settings.
Use the Identity Page
Entering host name, description, and location.
Use the Network Configuration Page
Setting DHCP and TCP/IP parameters.
Use the Services Page
Changing passwords and managing web server.
Work with the Browse Chassis Page
Viewing modules present on the system.
Appendix C Configure the RSLinx Ethernet Communication Driver
Overview
Configuring RSLinx drivers for network communication.
Install the RSLinx Software
Procedure for installing RSLinx software.
Configure the AB_ETH Driver
Setting up the AB_ETH communication driver.
Configure the AB_ETH/IP Driver
Setting up the AB_ETH/IP communication driver.

Table of Contents

Save PDF