IFM Electronic SU9000 Operating Instructions Manual

IFM Electronic SU9000 Operating Instructions Manual

Efector 300 series ultrasonic flow rate sensor

Advertisement

Operating instructions
Ultrasonic flow rate sensor
UK
SU7000
SU8000
SU9000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SU9000 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Preliminary note
Symbols used
Explains symbols used in the manual for clear communication and understanding.
Warning signs used
Details caution and warning signs to ensure user safety and prevent hazards.
Functions and features
Application area
Lists the types of media the ultrasonic flow rate sensor can monitor.
Function
Process measured signals
Describes the current process values and output signals generated by the unit.
Volumetric flow monitoring
Explains how volumetric flow is monitored using an ultrasonic system.
Consumed quantity monitoring (totaliser function)
Details the unit's internal quantity meter for tracking total flow.
Consumed quantity monitoring with pulse output
Explains how output 1 signals a counting pulse for volumetric flow quantity.
Consumed quantity monitoring with preset counter
Describes how output 1 switches based on preset volumetric flow quantity.
Temperature monitoring
Lists the signals provided for monitoring medium temperature.
Volumetric flow or temperature monitoring / switching function
Explains how the output status changes based on set switching limits.
Hysteresis function
Details the hysteresis switching function for stable output status.
Window function
Explains the window function where set and reset points define a range.
Volumetric flow or temperature monitoring / analogue function
Covers analogue output configurations for flow and temperature monitoring.
Voltage output 0 ... 10 V (example volumetric flow monitoring)
Describes the voltage output configuration for measuring volumetric flow.
Current output 4 ... 20 mA (example volumetric flow monitoring)
Details the current output configuration for measuring volumetric flow.
Start-up delay
Explains the start-up delay's influence on switching outputs.
Customer-specific calibration (CGA)
Allows changing the gradient of measured values to influence display and outputs.
Installation
Recommended mounting position
Provides guidelines on optimal placement for accurate measurements.
Non recommended installation position
Lists installation positions to avoid for proper operation.
Installation in pipes
Explains how to install the unit in pipes using adapters.
Menu
Menu structure
Visual representation of the device's menu hierarchy and parameters.
Explanation of the menu
Detailed descriptions of each parameter within the device menu.
Parameter setting
Parameter setting in general
Step-by-step guide for configuring parameters on the device.
Change from menu level 1 to menu level 2
Instructions for navigating to advanced menu levels for configuration.
Locking / unlocking
Procedures for electronically locking or unlocking the device settings.
Timeout
Explains the timeout behavior during parameter setting.
Settings for consumed quantity monitoring
Configure limit value monitoring with OUT1
Guides on setting limit values for output 1 in quantity monitoring.
Configure limit value monitoring with OUT2
Steps for configuring limit values for output 2 in quantity monitoring.
Configure analogue value for volumetric flow
Details on configuring analogue output for volumetric flow measurement.
Settings for consumed quantity monitoring
Configure quantity monitoring via pulse output
How to set up consumed quantity monitoring using a pulse output.
Configure quantity monitoring via the preset counter
Guides on configuring consumed quantity monitoring with a preset counter.
Setting the pulse value
Step-by-step process for setting the pulse value for quantity monitoring.
Manual counter reset
Instructions for manually resetting the counter.
Time-controlled counter-reset
How to configure automatic counter resets at timed intervals.
Deactivate meter reset
Option to deactivate automatic meter resets, relying on overflow.
Configure meter reset using an external signal
Setting up external signals for meter reset functionality.
Settings for temperature monitoring
Configure limit value monitoring with OUT2
Configuring limit values for temperature monitoring on output 2.
Configure analogue value for temperature
Setting up analogue output for temperature measurement.
User settings (optional)
Set standard unit of measurement for volumetric flow
How to set the units (L/min or m³/h) for volumetric flow display.
Configuration of the standard display
Customizing the standard display unit and update rate.
Setting the output logic
Configuring the output logic (PNP or NPN).
Calibrate curve of measured values
Adjusting the curve gradient for measured values.
Reset calibration data
Restoring calibration settings to factory defaults.
Setting the start-up delay
Configuring the duration of the start-up delay in seconds.
Set measured value damping
Setting the damping constant for measured values.
Set output status in fault condition
Defining output behavior during fault conditions.
Select the medium to be monitored
Choosing the specific medium being monitored from a list.
Service functions
Read min/max values for volumetric flow
Accessing and clearing recorded minimum and maximum flow values.
Reset all parameters to factory setting
Restoring the entire device configuration to factory defaults.
Operation
Reading the process value
How to read and interpret the current process values displayed on the unit.
Change display unit in the Run mode
Steps to switch between different display units while in operating mode.
Read set parameters
How to view the currently configured parameter values.
Fault indications
Explains various fault codes and their meanings for troubleshooting.

Table of Contents